Search
Advanced search
Filter by category
Filter by committee
Search results
-
ASTM International’s wear and erosion committee ( G02 ) has released a new standard that provides a test method for measuring friction and adhesive wear properties of lubricated and nonlubricated materials using the twist compression test (TCT). The new standard (soon to be published as G223) can be used to “rank combinations of surfaces in their resistance to adhesive wear. This can be useful…, Media Inquiries:, Gavin O’Reilly, tel +1.610.832.9618; goreilly@astm.org, Committee Contact:, Jennifer Tursi HER , tel +1.610.832.9653; jtursi@astm.org Release #11697 ###
-
ASTM International’s concrete pipe committee ( C13 ) has approved a new standard that will help in manufacturing circular concrete pipe that is installed using pipe jacking techniques. The type of pipe covered by the new standard is typically used to convey sewage, industrial wastes, stormwater, or utilities. Engineers, precast concrete pipe manufacturers, and jacking contractors will be the…
-
New ASTM International Standard Is First for Testing Corrosion Effects in Manufacturing of AdditivesA new standard developed by ASTM International’s concrete pipe committee ( C13 ) is the first standard test for determining the effectiveness of antimicrobial additives on the corrosion of concrete. “This standard presents test methods to help determine effects of biogenic acidification on concrete products and/or the efficacy of antimicrobial products to resist microbially-induced corrosion in…, Media Inquiries:, Jaime Martorana, tel +1.610.832.9796; jmartorana@astm.org, Committee Contact:, Jimmy Farrell, tel +1.610.832.9661; jfarrell@astm.org Release #11124 ###
-
A new ASTM International standard will serve as a guide for standards related to determining the effects of biogenic sulfuric acid on concrete products. ASTM’s concrete pipe committee approved the standard, which is soon to be published as C1894. According to ASTM International member Mel Marshall, the new standard fills the need for a guide that discusses microbially induced corrosion (MIC) of…, Media Inquiries:, Dan Bergels, tel +1.610.832.9602; dbergels@astm.org, Committee Contact:, Jimmy Farrell, tel +1.610.832.9661; jfarrell@astm.org Release #10898
-
A new ASTM International standard will support the sustainability and resiliency of concrete pipes that are reinforced by synthetic fibers. The new standard (soon to be approved as C1818, Specification for Rigid Synthetic Fiber Reinforced Concrete Culvert, Storm Drain and Sewer Pipe) describes a strong and durable option that can be used for underground piping. Pipes in this new standard are used…, ASTM Committee C13 on Concrete Pipe Next Meeting:, Nov. 15-18, 2015, November Committee Week, Tampa, Fla., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Ali Abolmaali, University of Texas, Arlington, Texas, tel +1.817.272.3877; abolmaail@uta.edu, ASTM Staff Contact:, Diane Lake, tel +1.610.832.9661; dlake@astm.org Release #9940
-
Precast reinforced concrete box sections are proving to be a versatile means for the development of infrastructure. The use of segmental box sections is now covered in an ASTM standard, ASTM C1786 , Specification for Segmental Precast Reinforced Concrete Box Sections for Culverts, Storm Drains and Sewers Designed According to AASHTO LRFD. The American Association of State Highway and…, Technical Contact:, Josiah W. Beakley, American Concrete Pipe Association, Irving, Texas, tel +1.972.894.2906; jbeakley@concrete-pipe.org, ASTM Staff Contact:, Diane Lake, tel +1.610.832.9661; dlake@astm.org, ASTM PR Contact:, Barbara Schindler, tel +1.610.832.9603; bschindl@astm.org Release #9745
-
Since the late 1970s, precast box sections have become an important component in the construction of culverts, storm drains and sewers, but there has not been a comprehensive standard for the installation of such sections. A new ASTM International standard fills this gap. ASTM C1675, Practice for Installation of Precast Reinforced Concrete Monolithic Box Sections for Culverts, Storm Drains and…, Technical Contact:, Roman Selig, Hamilton Kent LLC, Birmingham, Ala., Phone: 205-910-0690; roman.selig@hamiltonkent.com, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9243
-
Load and resistance factor design methodology developed by the American Association of State Highway and Transportation Officials plays a key role in a proposed ASTM standard on the design of culverts and storm drains. ASTM WK38166 , Specification for Manufacture of Precast Reinforced Concrete Three-Sided Structures for Culverts and Storm Drains Designed According to AASHTO LRFD, is being…, Technical Contact:, Balaram K. Singh, P.E., Michigan Department of Transportation, Lansing, Mich., Phone: 517-335-2174; singhb@michigan.gov, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact, : Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9311
-
A new ASTM International standard, adopted from an American Concrete Institute test method, will be used to help ensure the safety of construction projects. ASTM C1741 , Test Method for Bleed Stability of Cementitious Post-Tensioning Tendon Grout, is under the jurisdiction of Subcommittee C09.41 on Hydraulic Cement Grouts , part of ASTM International Committee C09 on Concrete and Concrete…
-
Piston ring/liner interface can contribute as much as half the total friction loss in internal combustion engines, with the resulting wear leading to reduced energy efficiency and raised emissions. A new ASTM International standard provides a method to more accurately measure small amounts of wear on curved piston ring segments and their counterfaces after lubricated bench-scale testing. “Coupled…