Search
Advanced search
Filter by category
Filter by committee
Search results
-
If you have a roof over your head, chances are very good that you have flashing over your head as well. Flashing serves as part of the weather resistant barrier systems that keep water from getting into a structure. A proposed new ASTM International guide will satisfy a market need for a standard to define durable flashing and will create a level playing field for flashing manufacturers. The…, ASTM Committee D08 Next Meeting:, Dec. 7-10, December Committee Week, New Orleans, La., Technical Contact:, Michael Schmeida, Oatey Co., Cleveland, Ohio, tel +1.216.898.3469; mschmeida@oatey.com, ASTM Staff Contact:, Joseph Hugo, tel +1.610.832.9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, tel +1.610.832.9603; bschindl@astm.org Release #9694
-
Excess moisture trapped in roofing or waterproofing systems can adversely affect performance, as well as lead to premature failure of a system and its components. Using an electrical impedance scanner is a fast and relatively easy way to conduct moisture surveys of roofing and waterproofing systems. A new ASTM International standard covers the use of electrical impedance scanners to monitor the…, ASTM Committee D08 Next Meeting:, Dec. 7-10, 2014, December Committee Week, New Orleans, La., Technical Contact:, Sean Fallon, Sean Fallon Consulting, Dublin, Ireland, Phone: +353-1-2851861; seanfallon14@gmail.com , ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9674
-
A proposed new ASTM standard will be used to ensure that the waterproofing of buildings is performing as intended. Once approved, the practice will be useful to architects, specifiers, membrane manufacturers, roofing contractors and warranty providers, as well as building owners, to test, verify and monitor the integrity of waterproof membranes. ASTM WK27666, Practice for Electrical Conductance…, ASTM Committee D08 Next Meeting:, June 22-25, 2014, June Committee Week, Toronto, Ontario, Canada, Technical Contact:, David Vokey, Detec Systems, Bellingham, Wash.; Phone: 360-961-9452; david.vokey@detecsystems.com , ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9593
-
ASTM International Committee D08 on Roofing and Waterproofing , through its Subcommittee D08.24 on Sustainability , is developing several standards for sustainable roofing systems. One such standard is ASTM WK26599 , Guide for Design of Sustainable, Low-Slope Roofing Systems. “The proposed standard embraces the fact that the primary purpose of the roofing system is to protect the top of the…, ASTM Committee D08 Next Meeting:, Dec. 8-11, 2013, December Committee Week, Jacksonville, Fla., Technical Contact:, Eric K. Olson, P.E., Simpson Gumpertz & Heger, Waltham, Mass., Phone: 781-907-9311; ekolson@sgh.com, ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9478
-
A proposed ASTM standard will reflect recent technological advances for asphalt adhesives. ASTM WK40056 , Specification for Adhesive Used with Modified Bituminous Sheet Materials, is being developed by Subcommittee D08.20 on Roofing Membrane Systems , part of ASTM International Committee D08 on Roofing and Waterproofing . “The proposed standard will provide a means of describing the changes that…, ASTM Committee D08 Next Meeting:, June 9-12, 2013, June Committee Week, Indianapolis, Ind., Technical Contact:, Carter C. Slusher, Firestone Building Products, Indianapolis, Ind., Phone: 317-575-7117; slushercarter@gbsg.net, ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9322
-
Coated fabric products used for oil spill response procedures can deteriorate when stored for long periods of time. A proposed new ASTM standard will provide a nondestructive test for stored equipment to be evaluated for continued suitability over time. ASTM WK37298 , Test Method for Determining Storage Life of Coated Fabric Products, is being developed by Subcommittee F20.11 on Control , part of…, ASTM Committee F20 Next Meeting:, Oct. 23-24, 2012, October Committee Week, Atlanta, Ga., Technical Contact:, Peter Lane, Applied Fabric Technologies Inc., Applied Fabric Technologies Inc., Morris Skimmers International LLC, Orchard Park, N.Y., Phone: 716-662-0632; lane@afti.com, ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9310
-
ASTM International Committee F20 on Hazardous Substances and Oil Spill Response has approved several standards for in-situ burning. The latest proposed standard on this subject, ASTM WK37324 , Guide for Evaluation of In-Situ Burning Effectiveness, is currently being developed by Subcommittee F20.15 on In-Situ Burning . In-situ burning is a controlled burning, at the spill location, of oil that…, ASTM Committee F20 Next Meeting:, Oct. 23-24, 2012, October Committee Week, Atlanta, Ga., Technical Contact:, Steve Potter, SL Ross Environmental Research Ltd., Ottawa, Ontario, Canada, Phone: 613-232-1564; steve@slross.com, ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-932-9738; jadkins@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9294
-
A new ASTM International standard provides information and guidelines for the selection and installation of drainage systems media that are used with waterproofing systems. ASTM D7492/D7492M , Guide for Use of Drainage System Media with Waterproofing Systems, was developed by Subcommittee D08.22 on Waterproofing and Dampproofing Systems, part of ASTM International Committee D08 on Roofing and…
-
A new ASTM International standard will be a useful document for vendors, buyers and regulators in determining the applicability of different types of booms to be used for oil spill response. ASTM F2683 , Guide for Selection of Booms for Oil Spill Response, was developed by Subcommittee F20.11 on Control , part of ASTM International Committee F20 on Hazardous Substances and Oil Spill Response .…
-
A new ASTM International standard will provide how-to information to consultants and contractors for assessing the condition of a roof to be coated and recommendations on how to prepare a roof for a coating. The new standard, ASTM D7120 , Guide for Evaluation and Preparation of Roof Membranes for Coating Application, was developed by Subcommittee D08.20 on Roofing Membrane Systems, part of ASTM…, ASTM Committee D08 Next Meeting:, June 12-15, 2011, June Committee Week, Anaheim, Calif., Technical Contact:, Carter Slusher, Firestone Building Products, Indianapolis, Ind., Phone: 317-575-7117; slushercarter@firesonebp.com, ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8721