Search
Advanced search
Filter by category
Filter by committee
Search results
-
Laboratories that have the ability to analyze titanium and titanium alloys by spark-atomic emission spectrometry or glow discharge-AES are currently being sought to participate in an interlaboratory study for a proposed new standard. ASTM WK25738 , Test Method for Analysis of Titanium and Titanium Alloys by Spark-Atomic Emission/Glow Discharge-Atomic Emission Spectrometry, is currently being…, ASTM Committee E01 Next Meeting:, May 15-18, 2011, May Committee Week, Anaheim, Calif., Technical Contact:, Kevin VonScio, Perryman Co., Houston, Pa., Phone: 724-746-9390; kvonscio@perrymanco.com, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8855
-
Trona, or sodium sesquicarbonate, is a fine mineral powder that has proven to be effective at removing acid gases from air emissions. While trona can be a useful component of air pollution control systems, it can be difficult to handle, particularly when moisture is present. A proposed new ASTM standard will present a repeatable, precise and accurate test method for analyzing moisture levels in…, ASTM Committee E01 Next Meeting:, Nov. 14-17, November Committee Week, San Antonio, Texas, Technical Contact: J, ames D. Phillip, Solvay Chemicals Inc, Green River, Wyo., Phone: 307-872-6519; jim.phillip@solvay.com, ASTM Staff Contact:, Thomas O'Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8608
-
Test Method Covers Inductively Coupled Plasma Atomic Emission Spectrometry, A new ASTM International standard will help users properly prepare and analyze various nickel-based alloy samples by inductively coupled plasma emission spectrometry. The standard, ASTM E2594 , Test Method for Analysis of Nickel Alloys by Inductively Coupled Plasma Atomic Emission Spectrometry (Performance-Based Method), will assist users in preparing sample and calibration solutions and with…
-
Advancing gas analysis technology is leading to the development of a proposed new ASTM International standard, WK22331 , Test Method for Simultaneous Determination of Oxygen, Nitrogen and Hydrogen in Titanium and Titanium Alloys by the Inert Gas Fusion Technique. Analyzers are now available that can simultaneously test titanium and titanium alloys for oxygen, nitrogen and hydrogen. This…
-
The use of rolling devices can provide a means to evaluate the adhesion of weather seals, for quality control in new installations, general evaluation of existing installations, and the investigation of water and air leakage through building enclosures. In order to better facilitate the use of rolling devices, ASTM International Committee C24 on Building Seals and Sealants is developing a…
-
Honeycomb ceramics, porous with linear hollow channels, are being used worldwide in automotive catalytic converters and as diesel particulate filters for trucks. Flexural testing of this type of ceramics is addressed in a new ASTM International standard, ASTM C1674 , Test Method for Flexural Strength of Advanced Ceramics with Engineered Porosity (Honeycomb Cellular Channels) at Ambient…
-
All interested parties are invited to join in the ongoing development of a proposed new standard, WK19982 , Test Method for ICP Analysis of Calcium and Magnesium in Magnesium Ferrosilicon. WK19982 is being developed by Subcommittee E01.01 on Iron, Steel and Ferroalloys, part of ASTM International Committee E01 on Analytical Chemistry for Metals, Ores and Related Materials. According to Robert…
-
Responding to requests from representatives of the copper industry, ASTM International Committee E01 on Analytical Chemistry for Metals, Ores and Related Materials has developed a new standard, E2575 , Test Method for Determination of Oxygen in Copper and Copper Alloys. The new standard is under the jurisdiction of Subcommittee E01.05 on Cu, Pb, Zn, Cd, Sn, Be, Their Alloys and Related Metals. …
-
New Advanced Ceramics Standards from ASTM Cover Fracture Mirror Size Analysis, Tensile Strength DataSubcommittee C28.01 on Mechanical Properties and Performance, part of ASTM International Committee C28 on Advanced Ceramics, has recently approved two new standards, ASTM C1678 , Practice for Fractographic Analysis of Fracture Mirror Sizes in Ceramics and Glasses, and ASTM C1683 , Practice for Size Scaling of Tensile Strengths Using Weibull Statistics for Advanced Ceramics., ASTM C1678 —Bringing Consistency to Fracture Mirror Size Analysis, Fracture mirror size analysis is a powerful quantitative tool for the interpretation of broken ceramic and glass articles. While this type of analysis can be used to determine the stress in a part at the instant of fracture, inspection and interpretation procedures have often varied, resulting in uncertainty in stress estimates. ASTM C1678, Practice for Fractographic Analysis of Fracture Mirror…, ASTM C1683 —Scaling Strength Values, ASTM C1683, Practice for Size Scaling of Tensile Strength Using Weibull Statistics for Advanced Ceramics, provides methodology to convert fracture strength parameters estimated from data obtained with one test geometry to strength parameters representing other test geometries. Stephen Duffy, chair of civil engineering, Cleveland State University, and C28 member, says that companies producing…
-
Ceramic and glass companies, as well as universities and government laboratories, will be the primary users of a new ASTM standard that allows for the flexural strength determination of components made in a round shape or after finish machining with minimal waste. The standard, ASTM C1684 , Test Method for Flexural Strength of Advanced Ceramics at Ambient Temperature-Cylindrical Rod Strength, was…