Search
Advanced search
Filter by category
Filter by committee
Search results
-
The polyethylene piping industry continues to increase the size of pipe diameters and pipe wall thicknesses used in the transportation of gas, water, and oil. The original reverse bend test in F2620 is of limited capability when testing heat fusion joints in wall pipe systems that are heavier with larger diameters. A new standard (soon to be published as F3183, Practice for Guided Side Bend…, ASTM Committee F17 on Plastic Piping Systems Next Meeting:, Nov. 14-17, 2016, November Committee Week, Orlando, Fla., Media Inquiries:, Dan Bergels, tel +1.610.832.9602; dbergels@astm.org, Technical Contact:, Steve Sandstrum, tel +1.502.318.6754; steve.sandstrum@isco-pipes.com, ASTM Staff Contact:, Robert Morgan, tel +1.610.832.9732; rmorgan@astm.org Release #10091
-
A new ASTM International standard will help train workers who operate heat fusion equipment (HFE) to fuse plastic pipes. This standard could help enhance safety for workers, ensure longevity of pipes, and strengthen infrastructure overall. Until now, there was not a guideline for properly training workers nor a description of requirements to qualify as an operator. (Many companies relied on HFE…, Committee F17 on Plastic Piping Systems Next Meeting:, Nov. 14-17, 2016, November Committee Week, Orlando, FL., Media Inquiries:, Dan Bergels, tel +1.610.832.9602; dbergels@astm.org, Technical Contact:, Jim Craig, Jim Craig Consulting, LLC; tel +1.918.720.3670; jcraig211@cox.net, ASTM Staff Contact:, Robert Morgan, +1.610.832.9732; rmorgan@astm.org Release #10077
-
A newly proposed standard ( WK54335 , Specification for Cellular Wall Polypropylene (PP) Chambers) concerning storm water collection chambers is being developed. With cellular wall PP chambers being installed as part of road and parking lot construction, wheel load and soil weight place significant structural demand on the product. A structurally sound product is essential to ensure the safety of…, Committee F17 on Plastic Piping Systems Next Meeting:, Nov. 14-17, 2016, November Committee Week, Orlando, Fla., Media Inquiries:, Dan Bergels, tel +1.610.832.9602; dbergels@astm.org, Technical Contact:, David Mailhot, Stormtech, South Coventry, Conn., tel +1.860.391.3672; david.mailhot@ads-pipe.com, ASTM Staff Contact:, Robert Morgan, tel +1.610.832.9732; rmorgan@astm.org Release #10074
-
Leo J. Titus, Jr., president of ECS Mid-Atlantic, LLC, in Chantilly, Va., has been named chairman of ASTM International Committee E36 on Accreditation & Certification . Formed in 1973, E36 has nearly 150 members and includes 5 technical subcommittees that oversee 8 standards related to operation and recognition of accreditation bodies and conformity assessment entities for calibration and…, Media Inquiries:, Dan Bergels, tel +1.610.832.9602; dbergels@astm.org Release #10036
-
Richard R. Geoffroy, director of engineering and applications at Polymer Services Group in Somers, Conn., has been named chairman of ASTM International Committee F17 on Plastic Piping Systems . Formed in 1973, F17 includes 18 subcommittees that oversee more than 180 standards related to specifications for plastic pipe, fittings, best practices for joining and installing plastic pipes, test…, Media Inquiries:, Dan Bergels, tel +1.610.832.9602; dbergels@astm.org Release #10029
-
Keeping birds away from potentially fatal encounters with building exteriors is the purpose of a proposed new ASTM International standard, ASTM WK47853 , Test Method for Bird Collision Deterrence Material Threat Factor. It is possible that as many as a billion birds are killed every year after colliding with glass on buildings, including many single-family homes — and this is in the United States…, ASTM Committee C14 Next Meeting:, April 14, 2015, Moorestown, N.J., Technical Contact:, Stefan Knust, Ennead Architects, New York, New York, tel +1.212.807.7171; sknust@ennead.com, ASTM Staff Contact:, Thomas O’Toole, tel +1.610.832.9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, tel +1.610.832.9603; bschindl@astm.org Release #9767
-
A proposed new ASTM International standard, ASTM WK39447 , Specification for Metric Outside Diameter Polyethylene (PE) Plastic Pressure Pipe (DR-PN), will cover premier high-density polyethylene compounds used in a variety of plastic piping systems throughout the world. “The proposed standard establishes material and product requirements, and tests for verification of compliance,” says ASTM…, ASTM Committee F17 Next Meeting:, Nov. 10-13, 2014, November Committee Week, New Orleans, La., Technical Contact:, William Adams, WSS Consulting, Terre Haute, Ind., Phone: 812-236-7791; wiia4676@gmail.com , ASTM Staff Contact:, Robert Morgan, Phone: 610-832-9732; rmorgan@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9577
-
Performance tests of potential personnel are becoming more commonly used as predictors of on-the-job performance. A new ASTM International standard is focused on 42 issues that are specific to personnel performance test development and implementation. ASTM E2849 , Practice for Professional Certification Performance Testing, was developed by Subcommittee E36.80 on Personnel Performance Testing and…, ASTM Committee E36 Next Meeting:, June 23-24, 2014, June Committee Week, Toronto, Ontario, Canada, Technical Contact:, Wallace Judd, CertNT LLC, Leesburg, Va, Phone: 703-884-2222 (ext. 802); wallace@wallacejudd.com, ASTM Staff Contact:, Rick Lake, Phone: 610-832-9689; rlake@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9565
-
A proposed new ASTM International standard will be used to cover requirements and test methods for a new type of pipe intended for industrial or oil and gas wastewater transfer. ASTM WK44033 , Specification for Fluid Composite Transfer Pipe and Fittings, is being developed by Subcommittee F17.68 on Energy Piping Systems , part of ASTM International Committee F17 on Plastic Piping Systems . Pipe…, ASTM Committee F17 Next Meeting:, April 7-10, 2014, April Committee Week, Toronto, Ontario, Canada, Technical Contact:, James Goddard, Powell, Ohio, Phone: 740-972-0012; jimgoddard3@gmail.com , ASTM Staff Contact:, Robert Morgan, Phone: 610-832-9732; rmorgan@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9538
-
ASTM International Committee F17 on Plastic Piping Systems is currently developing a proposed standard that will address the use of crosslinked polyethylene (PEX) tubing used in hydronic heating/cooling systems. The proposed new standard, ASTM WK38788 , Specification for Crosslinked Polyethylene (PEX) OD Controlled Tubing for Hydronic Heating/Cooling Systems, is under the jurisdiction of…, ASTM Committee F17 Next Meeting:, Nov. 11-14, 2013, November Committee Week, Jacksonville, Fla., Technical Contact:, Gary Morgan, Viega LLC, Wichita, Kan., Phone: 620-480-1222; garymorgan@viega.com , ASTM Staff Contact:, Robert Morgan, Phone: 610-832-9732; rmorgan@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9361