A new ASTM International standard will help specify manufacturing requirements for bimetallic tracer wire, which allows detection of underground utilities. The organization’s electrical conductors committee (B01) developed the new standard, soon to be published as B1010. According to ASTM International member Landyn Masoner, a process engineer with Copperweld Bimetallics LLC, tracer wire (also…, Media Inquiries:, Dan Bergels, tel +1.610.832.9602; dbergels@astm.org, Committee Contact:, Kristy Straiton, tel +1.610.832.9640; kstraiton@astm.org Release #10902
-
A new ASTM International specification will help standardize production and use of bimetallic “busbar” (copper-clad aluminum flat-strip and flat-wire that distributes high-current power). A copper-clad aluminum electrical conductor is a cost-effective alternative to pure copper or aluminum conductors. “The need for this standard is global.” said Dustin Fox, the chairman of the committee on…, Committee on Electrical Conductors (B01) Next Meeting:, Oct. 11-12, New Orleans, La., Media Inquiries:, Dan Bergels, tel +1.610.832.9602; dbergels@astm.org, Technical Contact:, Liang Yuncheng, Yantai Fisend Bimetal Co., Yantai City, Shangdong Province, China, tel +86.186.605.51330; brianlrc@fisend.com, Staff Contact:, Kristy Straiton, tel +1.610.832.9640; kstraiton@astm.org R elease #10320
-
A new standard will help test technology that is used in many electronic devices. According to ASTM members Lin Tingyu (National Center for Advanced Packaging) and Hi Jinjiang (Grikin Advanced Materials Co. Ltd.), the new standard will provide a baseline of quality, reliability, and process for manufacturers of “sputtering targets,” which are often used for thin-film deposition, etching, and…, ASTM Committee F01 on Electronics Next Meeting:, January 31, 2017, January Committee Week, Norfolk, Va., Media Inquiries:, Dan Bergels, tel +1.610.832.9602; dbergels@astm.org, Technical Contact:, Lin Tingyu, National Center for Advanced Packaging, Wuxi, Jiangsu province, China, tel +1.535.805.3318; tingyulin@ncp-cn.com, ASTM Staff Contact:, Kelly Paul, tel +1.610.832.9745; kpaul@astm.org Release #10163
-
A proposed ASTM standard could help improve workplace safety by describing proximity alarm systems that can be used to prevent cranes, utility trucks, and other equipment from encroaching inside OSHA minimum approach distances and contacting high-voltage power lines. The standard would be most useful to the construction industry, but it could also help in firefighting, drilling, mining,…, ASTM Committee F18 on Electrical Protective Equipment for Workers Next Meeting:, Oct. 4-7, 2015, Las Vegas, Nev., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Lance Burney, Sigalarm, Sanford, Fla., tel +1.407.321.0722; lance@sigalarminc.com , ASTM Staff Contact:, Kevin Shanahan, tel +1.610.832.9737; kshanahan@astm.org Release #9903
-
Overhead conductors used to transmit electricity typically consist of stranded aluminum wires that surround a stranded steel wire core. However, a more recently developed conductor consists of composite materials of carbon and glass fibers that replace the stranded steel-supporting member. This new type of conductor will be covered in a new ASTM International standard, ASTM B987 , Specification…, ASTM Committee B01 Next Meeting:, April 29, 2015, April Committee Week, Anaheim, Calif., Technical Contact:, Eric Bosze, Ph.D., CTC Global, Irvine, Calif., Phone: +1.949.381.7262; ebosze@ctcglobal.com, ASTM Staff Contact:, Kristy Straiton, Phone: +1.610.832.9640; kstraiton@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: +1.610.832.9603; bschindl@astm.org Release #9694
-
Since 2009, the National Fire Protection Association has required arc rated gloves in its NFPA70E, Standard for Electrical Safety in the Workplace. A new ASTM standard will now provide arc rating thermal protective values for gloves, which will allow more gloves to be used inside an arc flash zone when there is no shock hazard. The new standard, ASTM F2675/F2675M , Test Method for Determining Arc…, ASTM Committee F18 Next Meeting:, Oct. 20-23, 2013, Charleston, S.C., Technical Contact:, Hugh Hoagland, ArcWear, Louisville, Ky., Phone: 502-832-9737; hugh@arcwear.com , ASTM Staff Contact:, Kevin Shanahan, Phone: 610-832-9737, kshanahan@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9469
-
ASTM B986 , Test Method for Determination of Tensile Strength by Mass Method for Stranded Conductors Intended for use in Electronic Application, will be used within the electronics and aerospace industries to validate tensile strength specification requirements for electrical conductors. ASTM B986 was developed by Subcommittee B01.02 on Methods of Test and Sampling Procedure , part of ASTM…, ASTM Committee B01 Next Meeting:, Oct. 23, 2013, October Committee Week, Jacksonville, Fla., Technical Contact:, Stephen Childers, IWG High Performance Conductors Inc., Inman, S.C., Phone: 864-472-0438; stephen.childers@iwghpc.com , ASTM Staff Contact:, Kristy Straiton, Phone: 610-832-9640; kstraiton@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9364
-
The construction of an unprecedented number of overhead power lines around the world has increased the demand for accurate data and models for electrical conductors. A proposed new standard, ASTM WK35208, Test Methods for Stress-Strain and Creep Testing for Overhead Electrical Conductors, will answer this global need. ASTM WK35208 is being developed by Subcommittee B01.02 on Methods of Test and…
-
A proposed new standard being developed by ASTM International Committee F18 on Electrical Protective Equipment for Workers will provide guidance to assist in the required testing of live-line tools. ASTM WK33590 , Guide for In-Service Inspection, Maintenance and Electrical Testing of Insulating Tools (Fiberglass-Reinforced Plastic (FPR) and Wooden Live-Line Tools), is under the jurisdiction of…
-
Code words have historically been used in the electrical conductor industry as a simple method of identifying the construction details of an overhead conductor product. A proposed new ASTM standard will list code word names and provide a means to register and publish new code words. ASTM WK28737 , Specification for Electrical Overhead Conductor Code Word Names, is being developed by Subcommittee…, ASTM Committee B01 Next Meeting:, Oct. 13, October Committee Week, San Antonio, Texas, Technical Contact:, Gordon Baker, General Cable, Highland Heights, Ky., Phone: 859-572-8493; gbaker@generalcable.com, ASTM Staff Contact:, Jennifer Rodgers, Phone: 610-832-9694; jrodgers@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8613