Search
Advanced search
Filter by category
Filter by committee
Search results
-
Rheologists are encouraged to join in the development of a proposed new practice that will help standardize calibration of rotational rheometers to obtain accurate normal force measurements. ASTM WK33687 , Practice for Normal Force Calibration for Rotational Rheometers, is being developed by Subcommittee E37.08 on Rheology , part of ASTM International Committee E37 on Thermal Measurements . The…, ASTM Committee E37 Next Meeting:, Aug. 10-11, in conjunction with the North American Thermal Analysis Society Annual Conference, Des Moines, Iowa, Technical Contact:, Kenneth Aniunioh, Shimadzu Scientific Instruments, Laurel, Md., Phone: 864-633-7690; kenebaano@yahoo.com, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8923
-
A new ASTM International standard will provide a method of testing corrosion-resistant fasteners and their performance in contact with treated wood. ASTM G198 , Test Method for Determining the Relative Corrosion Performance of Driven Fasteners in Contact with Treated Wood, was developed by Subcommittee G01.14 on Corrosion of Metals in Construction Materials , part of ASTM International Committee…
-
Corrosion inhibitors are used extensively for pipelines in the oil and gas industry. Subcommittee G01.05 on Laboratory Corrosion Tests has been developing a series of standards on performance testing of corrosion inhibitors, including the most recently approved: ASTM G202 , Test Method for Using Atmospheric Pressure Rotating Cage. Subcommittee G01.05 is part of ASTM International Committee G01 on…
-
The ASTM International Proficiency Testing Center is pleased to offer a 2010 Proficiency Testing Program on Thermal Analyses of Plastics (TAP) to laboratories who need a statistical quality assurance tool that will enable them to improve and maintain a high level of performance in conducting ASTM Differential Scanning Calorimetry (DSC), Oxidative-Induction Time (OIT) by Differential Scanning…, ASTM D3418, , Standard Test Method for Transition Temperatures and Enthalpies of Fusion and Crystallization of Polymers by Differential Scanning Calorimetry (DSC);, ASTM D3850, , Standard Test Method for Rapid Thermal Degradation of Solid Electrical Insulating Materials By Thermogravimetric Method (TGA); and, ASTM D3895, , Standard Test Method for Oxidative-Induction Time of Polyolefins by Differential Scanning Calorimetry. For each test trial, laboratory participants receive two sample materials along with interactive electronic data report forms and test instructions. Using the specified ASTM program tests, participating laboratories conduct the tests of their choice that they routinely run. Upon completion of…
-
Localized corrosion, such as pitting, cracking or crevice corrosion, can be destructive to process equipment, but if it is detected early enough, potential damage can be minimized or avoided. A new ASTM International standard provides a means for electrochemical testing for corrosion. The new standard, G199 , Guide for Electrochemical Noise Measurement, was developed by Subcommittee G01.11 on…
-
A new ASTM International standard will have applications in a variety of factories, on artificial turfs and playing surfaces, and even in the classroom. The new standard, G194 , Test Method for Measuring Rolling Friction Characteristics of a Spherical Shape on a Flat Horizontal Surface, was developed by Subcommittee G02.50 on Friction, part of ASTM International Committee G02 on Wear and Erosion…
-
Testing the oxygen permeation of packaging material is important for the suppliers of various barrier materials, as well as users of these materials in the food, pharmaceutical and consumer product companies, universities, research organizations and other industries. This kind of testing is covered in a new ASTM International standard approved by Committee F02 on Flexible Barrier Packaging, F2622…
-
Sterilized medical devices are indispensable to doctors and surgeons around the world. Peel pouches, otherwise known as preformed sterile barrier systems, are used to keep these devices sterile during all physical handling. These pouches can be made with a wide variety of material and are produced by many different suppliers, but the trait all pouches must share is the ability to protect devices…
-
A need for a new test method to determine the effective thermal conductivity of fire resistive materials at high temperatures has prompted ASTM International Committee E37 on Thermal Measurements to begin work on a proposed new standard, WK12643 , Test Method for Slug Calorimetry. The proposed standard is under the jurisdiction of Subcommittee E37.05 on Thermophysical Properties. According to…
-
ASTM International Subcommittee G01.10 on Corrosion in Soils will be conducting two round robin testing procedures on Tuesday, November 14, from 9:00 a.m. to 3:00 p.m. during ASTM meetings in Atlanta, Ga. One round robin will be for the development of a new standard test method to measure the oxidation-reduction potential (redox) of soils, while the other will address precision and bias for the 4…