A proposed new ASTM standard will provide a lab test to determine how various types of oil will interact with water in oil spill situations. Information gleaned from such testing will ultimately lead to more effective oil spill recovery. All interested parties are welcome to join in the ongoing development of the standard ( WK41247 , Test Method for the Evaluation of the Stability of Water-in-Oil…, ASTM Committee F20 on Hazardous Substances and Oil Spill Response Next Meeting:, Oct. 27-28, 2015, October committee week, Tampa, Fla., Technical Contact:, Mervin Fingas, Edmonton, Alberta, Canada, tel +1.780.989.6059; fingasmerv@shaw.ca, ASTM Staff Contact:, Jeffrey Adkins, tel +1.610.832.9738; jadkins@astm.org, ASTM PR Contact:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org Release #9772
-
In order to keep sound that travels beyond the walls of a particular area, such as medical examination rooms and human resources offices from being overheard by unintended listeners, an ASTM subcommittee specializing in speech privacy is at work on a proposed new standard, WK47433, Performance Specification of Electronic Sound Masking When Used in Building Spaces. “Electronic sound masking…, ASTM Committee E33 Next Meeting:, April 27-28, 2015, April committee week, Anaheim, Calif., Technical Contact:, Kenneth P. Roy, Armstrong World Industries, Lancaster, Pa., tel +1.717.396.5700; kproy@armstrong.com, ASTM Staff Contact:, Kelly Paul, tel +1.610.832.9745; kpaul@astm.org, ASTM PR Contact:, Barbara Schindler, tel +1.610.832.9603; bschindl@astm.org Release #9752
-
Since 2009, the National Fire Protection Association has required arc rated gloves in its NFPA70E, Standard for Electrical Safety in the Workplace. A new ASTM standard will now provide arc rating thermal protective values for gloves, which will allow more gloves to be used inside an arc flash zone when there is no shock hazard. The new standard, ASTM F2675/F2675M , Test Method for Determining Arc…, ASTM Committee F18 Next Meeting:, Oct. 20-23, 2013, Charleston, S.C., Technical Contact:, Hugh Hoagland, ArcWear, Louisville, Ky., Phone: 502-832-9737; hugh@arcwear.com , ASTM Staff Contact:, Kevin Shanahan, Phone: 610-832-9737, kshanahan@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9469
-
A proposed new ASTM International standard will be helpful to the construction industry in designing acoustic properties for buildings. ASTM WK37294 , Test Method for the Laboratory Measurement of Mechanical Impedance of Building Elements and Prediction of the Sound Transmission Loss Performance, is currently being developed by Subcommittee E33.03 on Sound Transmission , part of ASTM…, ASTM Committee E33 Next Meeting:, April 15-16, 2013, April Committee Week, Indianapolis, Ind., Technical Contact:, Peter Jackson, Ward Process, Holliston, Mass., Phone: 774-233-7011; p.jackson@aapusa.com, ASTM Staff Contact:, Steve Mawn, Phone: 610-832-9726; smawn@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9316
-
Coated fabric products used for oil spill response procedures can deteriorate when stored for long periods of time. A proposed new ASTM standard will provide a nondestructive test for stored equipment to be evaluated for continued suitability over time. ASTM WK37298 , Test Method for Determining Storage Life of Coated Fabric Products, is being developed by Subcommittee F20.11 on Control , part of…, ASTM Committee F20 Next Meeting:, Oct. 23-24, 2012, October Committee Week, Atlanta, Ga., Technical Contact:, Peter Lane, Applied Fabric Technologies Inc., Applied Fabric Technologies Inc., Morris Skimmers International LLC, Orchard Park, N.Y., Phone: 716-662-0632; lane@afti.com, ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9310
-
ASTM International Committee F20 on Hazardous Substances and Oil Spill Response has approved several standards for in-situ burning. The latest proposed standard on this subject, ASTM WK37324 , Guide for Evaluation of In-Situ Burning Effectiveness, is currently being developed by Subcommittee F20.15 on In-Situ Burning . In-situ burning is a controlled burning, at the spill location, of oil that…, ASTM Committee F20 Next Meeting:, Oct. 23-24, 2012, October Committee Week, Atlanta, Ga., Technical Contact:, Steve Potter, SL Ross Environmental Research Ltd., Ottawa, Ontario, Canada, Phone: 613-232-1564; steve@slross.com, ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-932-9738; jadkins@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9294
-
A proposed new standard being developed by ASTM International Committee F18 on Electrical Protective Equipment for Workers will provide guidance to assist in the required testing of live-line tools. ASTM WK33590 , Guide for In-Service Inspection, Maintenance and Electrical Testing of Insulating Tools (Fiberglass-Reinforced Plastic (FPR) and Wooden Live-Line Tools), is under the jurisdiction of…
-
A new ASTM International standard will be a useful document for vendors, buyers and regulators in determining the applicability of different types of booms to be used for oil spill response. ASTM F2683 , Guide for Selection of Booms for Oil Spill Response, was developed by Subcommittee F20.11 on Control , part of ASTM International Committee F20 on Hazardous Substances and Oil Spill Response .…
-
Standards developed by ASTM International Committees F20 on Hazardous Substances and Oil Spill Response and E47 on Biological Effects and Environmental Fate play a role in both the initial response and follow-up to oil spills. The recent spill in the Gulf of Mexico highlights the importance of standards that cover all aspects of oil spill response and cleanup. F20 on Hazardous Substance and Oil…
-
Arc protective blankets are used in many electrical applications to protect workers who are stationed near energized electrical parts. While these blankets have been used for years, there have been no testing criteria for their evaluation. A new ASTM International standard will be used to determine the effectiveness of arc protective blankets in suppressing the combined effect of an arc flash and…