Search
Advanced search
Filter by category
Filter by committee
Search results
-
Six months after the spring 2008 publication of ASTM standard E2600 , Practice for Assessment of Vapor Intrusion into Structures on Property Involved in Real Estate Transactions, the task group that developed it surveyed users to receive feedback on the new standard. According to Anthony Buonicore, CEO of the Buonicore Group and chair of the vapor intrusion task group, the survey results have led…
-
Subjects Include Vented Construction Systems, Furnace Exposure and Tunnel Fire Resistance, Subcommittee E05.11 on Fire Resistance, part of ASTM International Committee E05 on Fire Standards, is currently developing a number of proposed standards, including the following three test methods on vented construction systems, furnace exposure on test samples and tunnel fire resistance. All parties interested in working on fire resistance standards are encouraged to join in the activities of…, Vented Construction, Understanding how construction systems will perform in the earliest moments of a fire is crucial. A proposed new ASTM standard, WK22660 , Test Method for Evaluating Fire Performance of Vented Construction, will provide tests for evidence on how vented construction systems are affected by the first five minutes of a fire and will be used to complement existing fire testing methods test results “…, Furnace Exposure, Fire test laboratories and fire protection engineers will be the primary users of proposed new standard ASTM WK23795 , Test Method for Measuring the Uniformity of Furnace Exposure on Test Samples. The proposed standard provides general principles for measuring the uniformity of furnace exposure on samples tested in accordance with the following standards: - ASTM E119 , Test Methods for Fire…, Tunnel Fire Resistance, Fires in tunnels can reach temperatures as high as 2,500°F [1371°C], but current standards that deal with building fires provide for a maximum temperature of 2,000°F [1093°C] and are not specific to tunnels. A proposed new standard, ASTM WK23821 , Test Methods for Tunnel Fire Resistance, will be developed with the special considerations of tunnel fires in mind. According to Barry Badders, manager…
-
The U.S. Environmental Protection Agency has determined that the 2008 revision to an ASTM International standard describing the environmental assessment needs of parties involved in the acquisition of forestland and rural properties is now compliant with the agency’s All Appropriate Inquiries Rule (40 CFR Part 312, Standards and Practices for All Appropriate Inquires). The EPA decision came in a…
-
With the proposed new standard, WK11023 , Practice for Life and Reliability Testing Based on the Exponential Distribution, ASTM International Committee E11 on Quality and Statistics is continuing its program of preserving U.S. government military standards on acceptance sampling. WK11023 is an adaptation of the DoD quality control and reliability handbook document H-108, Sampling Procedures and…
-
No industry standard currently exists that addresses the vacuum sealing requirements of knife-edged flanges for high vacuum applications. Existing international standards focus on interchangeability of the hardware, but do not address the reliability of the seal. ASTM International Committee E42 on Surface Analysis is now working on a proposed standard on the subject, WK21206 , Specification…
-
A 2002 workshop on galling wear held by ASTM International Committee G02 on Wear and Erosion provided the impetus for the development of a new standard, ASTM G196 , Test Method for Galling Resistance of Material Couples. The new standard is under the jurisdiction of Subcommittee G02.40 on Non-Abrasive Wear. According to Scott Hummel, Ph.D., associate professor, head of the department of…
-
The ASTM standard that describes the environmental assessment needs of parties involved in the acquisition of forestland and rural property has been revised. The revision is an important step toward making ASTM E2247 , Practice for Environmental Site Assessments: Phase I Environmental Site Assessment Process for Forestland or Rural Property, compliant with the U.S. Environmental Protection Agency…
-
Vapor intrusion from contaminated soil and groundwater into structures can potentially create significant liability and have a material impact on property value. Because of this, accurately determining whether a property has vapor intrusion issues is a concern for property owners, prospective purchasers and environmental professionals conducting due diligence. ASTM International Committee E50 on…
-
A new ASTM International standard, E 2555 , Practice for Factors and Procedures for Applying the MIL-STD-105 Plans in Life and Reliability Inspection, represents the latest work of a task group that is converting a series of old U.S. Department of Defense standards into ASTM documents. The task group is part of Subcommittee E11.30 on Data Analysis, which is under the jurisdiction of ASTM…
-
Information on light nonaqueous-phase liquids and their impact on the environment has grown significantly in the last 20 years. This accumulation of knowledge means that different remediation strategies are now available for sites that contain these substances. In order to facilitate decision making, ASTM International Committee E50 on Environmental Assessment has developed a new standard, E 2531…