Search
Advanced search
Filter by category
Filter by committee
Search results
-
A proposed new ASTM International standard is being developed for mounting plastic pipe and tube in the Steiner tunnel furnace. The draft procedure will help determine the fire-related properties of the pipe and tube in accordance with ASTM E84, Test Method for Surface Burning Characteristics of Building Materials. ASTM WK44535 , Practice for Mounting of Plastic Pipe, Plastic Tubing, Plastic Pipe…, ASTM Committee E05 Next Meeting:, June 23-26, 2014, June Committee, Toronto, Ontario, Canada, Technical Contact:, Joe Zicherman, Fire Cause Analysis, Berkeley, Calif., Phone: 510-649-1300; zicherman46@gmail.com, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9635
-
A wildland-urban interface is a transitional zone between unoccupied land and human development. There are currently more than 40 million homes located within WUI areas throughout the United States. A proposed new ASTM standard will be used to alleviate the issue of fire conditions that exist due to eaves and other projections in structures that exist in WUI areas. ASTM WK37414, Test Method for…, ASTM Committee E05 Next Meeting:, June 23-26, 2014, June Committee Week, Toronto, Ontario, Canada, Technical Contact:, John Simontacchi, Firefree Coatings Inc., San Rafael, Calif., Phone: 415-459-6488; jsimontacchi@firefree.com , ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9529
-
The International Maritime Organization’s Fire Test Procedures Code provides test procedures for cable transits to allow for penetration through A-Class divisions, namely bulkheads and decks. However, there are many firestop penetration devices for cables and other installation methods that do not conform to the examples provided in the IMO FTP Code. Testing for these devices falls to the…, ASTM Committee F25 Next Meeting:, Dec. 10-12, 2013, December Committee Week, Jacksonville, Fla., Technical Contact:, Juan Manuel Flores, P.E., Intertek Commercial and Electrical, Elmendorf, Texas, Phone: 210-635-8100; juan.flores@intertek.com , ASTM Staff Contact:, Robert Morgan, Phone: 610-832-9732; rmorgan@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9508
-
A proposed new ASTM International standard will provide an up-to-date method for the aluminum industry to analyze samples by inductively coupled plasma-atomic emission spectroscopy. The proposed new standard, WK35993 , Test Method for Analysis of Aluminum and Aluminum Alloys by Inductively Coupled Plasma Atomic Emission Spectrometry (Performance Based Method), is being developed by Subcommittee…
-
A new ASTM International standard covers the principal dimensions and materials of closed chocks, used for mooring, for installation on ships. The new standard, ASTM F2935 , Specification for Chocks, Ship Mooring, Cast Steel, has been developed by Subcommittee F25.01 on Structures , part of ASTM International Committee F25 on Ships and Marine Technology . Chocks are mounted directly on the deck,…
-
A new test method is the latest in a series of ASTM International standards being developed to address the protection of exterior portions of structures during fires. The new standard, ASTM E2726/E2726M , Test Method for Evaluating the Fire-Test-Response of Deck Structures to Burning Brands, is being developed by Subcommittee E05.14 on External Fire Exposures , part of ASTM International…
-
A new ASTM standard will provide the United States building codes with a test method designed to test a heating, ventilation and air conditioning duct system or its materials for fire resistance and other durability requirements. ASTM E2816 , Test Methods for Fire Resistive Metallic HVAC Duct Systems, was developed by Subcommittee E05.11 on Fire Resistance , under the jurisdiction of ASTM…
-
A new ASTM International standard, adopted from an American Concrete Institute test method, will be used to help ensure the safety of construction projects. ASTM C1741 , Test Method for Bleed Stability of Cementitious Post-Tensioning Tendon Grout, is under the jurisdiction of Subcommittee C09.41 on Hydraulic Cement Grouts , part of ASTM International Committee C09 on Concrete and Concrete…
-
Piston ring/liner interface can contribute as much as half the total friction loss in internal combustion engines, with the resulting wear leading to reduced energy efficiency and raised emissions. A new ASTM International standard provides a method to more accurately measure small amounts of wear on curved piston ring segments and their counterfaces after lubricated bench-scale testing. “Coupled…
-
Fiber reinforced plastic gratings are often used as walkways for a variety of marine vessels. A proposed new ASTM International standard will cover several aspects of fiber reinforced plastic gratings, including fire testing procedures, ultraviolet effects and moisture absorption. The proposed standard, ASTM WK31924 , Specification for Fiber Reinforced Plastic (FRP) Gratings Used in Marine…, ASTM Committee F25 Next Meeting:, May 17-19, 2011 May Committee Week, Anaheim, Calif., Technical Contact:, John H. Miller, U.S. Coast Guard, Washington, D.C., Phone: 201-372-1372; john.h.miller@uscg.mil, ASTM Staff Contact:, Robert Morgan, Phone: 610-832-9732; rmorgan@astm.org R elease #8816