ASTM International Committee F17 on Plastic Piping Systems is currently working on a series of proposed new standards for polyethylene pipe fittings. The proposed standards will enable pipeline and piping project development using uniform fittings dimensions from every fabricator. “Today the consulting and engineering community uses 3-D modeling to develop and check project piping,” says Harvey…, ASTM Committee F17 Next Meeting:, April 16-18, 2012, April Committee Week, Phoenix, Ariz., Technical Contact:, Harvey Svetlik, Independent Pipe Products, Dallas, Texas, Phone: 800-499-6927; hsvetlik@indpipe.net, ASTM Staff Contact:, Robert Morgan, Phone: 610-832-9732; rmorgan@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9109
-
A new ASTM standard will provide the United States building codes with a test method designed to test a heating, ventilation and air conditioning duct system or its materials for fire resistance and other durability requirements. ASTM E2816 , Test Methods for Fire Resistive Metallic HVAC Duct Systems, was developed by Subcommittee E05.11 on Fire Resistance , under the jurisdiction of ASTM…
-
Although PVC gasketed sewer basins are currently being produced and supplied to the storm drainage market, there are not currently minimum requirements users can refer to for a purchase. A proposed new ASTM International standard will provide these requirements. ASTM WK32336 , Specification for Poly(Vinyl Chloride) (PVC) Gasketed Sanitary and Storm Drainage Sewer Basins and Fittings, is being…
-
Ensuring effective knowledge of underground assets and systems is essential for gas utility companies that are implementing plans to address regulatory initiatives and reporting requirements. A new ASTM International specification provides a comprehensive plan for tracking and tracing these assets. The new standard, ASTM F2897 , Specification for Tracking and Traceability Encoding System of…
-
Fire test laboratories, caulk and sealant manufacturers, and code officials will be the primary users of a new ASTM International standard, ASTM E2690 , Practice for Specimen Preparation and Mounting of Caulks and Sealants to Assess Surface Burning Characteristics. The standard was developed by Subcommittee E05.22 on Surface Burning, which is part of ASTM International Committee E05 on Fire…, ASTM Committee E05 Next Meeting:, June 12-15, 2011, June Committee Week, Anaheim, Calif., Technical Contact:, Paul Hough, Armstrong World Industries, Lancaster, Pa., Phone: 717-396-4195; pahough@armstrong.com, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8723
-
Innovations in the equations and other analytical tools that engineers have used when designing close-fit liners for plastic pipe have led to a need for a new standard for design calculations. This need will be met by a proposed new ASTM International standard, ASTM WK29237, Practice for Design Calculations of Close-Fit Liners. The proposed new standard is being developed by Subcommittee F17.67…
-
Non-destructive moisture meters are now widely used in determining moisture levels in concrete, gypsum concrete and other types of floor slabs. A new ASTM International standard qualifies the types of meter suitable for this purpose and provides guidelines for how, where and when such moisture meters are used and what limitations exist. The new standard, ASTM F2659 , Guide for Preliminary…, ASTM Committee F06 Next Meeting:, Nov. 10-11, New Orleans, La., Technical Contact:, Sean Fallon, Dublin, Ireland, Phone: +011-353-1-285-1861; seanfallon@ireland.com, ASTM Staff Contact:, Stephen Mawn, Phone: 610-832-9726; smawn@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #870/Oct2010
-
Subcommittee E05.11 on Fire Resistance is responsible for two new standards recently approved by ASTM International Committee E05 on Fire Standards. FIRE-RESISTANCE EXPERIMENTS It is a common practice to modify the tests contained in ASTM E119 , Test Methods for Fire Tests of Building Construction and Materials, in order to gather information on the effect of altering specific variables. However…
-
ASTM International Committee F17 on Plastic Piping Systems has just completed the development of two new standards for polypropylene sanitary sewer pipe. These new standards are the first to address both dual wall and triple wall profile designs. “Polypropylene has unique material characteristics, which make it ideal for sanitary sewer pipe applications,” says John Kurdziel, director, technical…
-
A newly approved ASTM International standard provides a procedure for safely conducting leakage tests of polyethylene pressure piping systems with compressed gaseous testing media. The new standard, ASTM F2786 , Practice for Field Leak Testing of Polyethylene (PE) Pressure Piping Systems Using Gaseous Media Under Pressure (Pneumatic Leak Testing), was developed by Subcommittee F17.40 on Test…