Search
Advanced search
Filter by category
Filter by committee
Search results
-
A new ASTM International standard will be used to help measure the potential for metal corrosion in aquatic environments such as piers, docks, vessels, and pipelines transporting natural gas and other flammable fluids at high pressure. The new standard (G215, Guide to Electrode Potential Measurement) will lead to a better understanding of electrode potential measurement. “The new standard should…, Committee G01 on Corrosion of Metals Next Meeting:, Nov. 13 -14, 2016, November Committee Week, Atlanta, GA., Media Inquiries:, Dan Bergels, tel +1.610.832.9602; dbergels@astm.org, Technical Contact:, Sheldon Dean, Jr., tel +1.610.428.5602; sheldondean@att.net, ASTM Staff Contact:, Krista Robbins, tel +1.610.832.9689; krobbins@astm.org Release #10083
-
ASTM International’s Fire Committee ( E05 ) is developing a standard that will test fire resistance of wooden utility poles. Utility companies and coating and treatment manufacturers will use the standard to test new products that could protect the poles. “Utility poles are frequently exposed to high intensity wildfires throughout the world,” says ASTM member Brent M. Pickett, Ph.D. “If these…, ASTM Committee E05 on Fire Next Meeting:, June 27-30, 2016, June Committee Week, Chicago, Ill., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Brent M. Pickett, Ph.D., Western Fire Center Inc., Kelso, Wash., tel +1.360.423.1400; brent@westernfire.com , ASTM Staff Contact:, Thomas O’Toole, tel +1.610.832.9739; totoole@astm.org Release #9989
-
A proposed new ASTM International standard will aid in understanding thermal transport properties, an important component in optimizing the energy efficiency of building materials and improving thermal design in electronics, fuel cells and batteries. The test described in ASTM WK46204, Test Method for Determination of Thermal Conductivity and Thermal Diffusivity of Solids and Fluids Using the…, ASTM Committee E37 Next Meeting:, Aug. 29, University of Delaware Center for Composite Materials, Newark, Del., Technical Contact:, Mattias Gustavsson, Ph.D., Hot Disk AB, Gothenburg, Sweden, Phone: +46-31-411-410; mattias.gustavsson@hotdiskinstruments.com , ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9629
-
Adopted in 2005, Chapter 7A of the California Building Code describes provisions for attic vents for new construction in wildfire-prone areas. While the California code notes that attic vents should resist the intrusion of embers and flames, there had not been a standard to evaluate such intrusion. A new standard, ASTM E2886/E2886M , Test Method for Evaluating the Ability of Exterior Vents to…, ASTM Committee E05 Next Meeting:, Dec. 8-11, 2014, December Committee, New Orleans, La., Technical Contact:, Stephen Quarles, Insurance Institute for Business and Home Safety, Richburg, S.C., Phone: 803-789-4209; squarles@ibhs.org , ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9617
-
A proposed new ASTM International standard is being developed for mounting plastic pipe and tube in the Steiner tunnel furnace. The draft procedure will help determine the fire-related properties of the pipe and tube in accordance with ASTM E84, Test Method for Surface Burning Characteristics of Building Materials. ASTM WK44535 , Practice for Mounting of Plastic Pipe, Plastic Tubing, Plastic Pipe…, ASTM Committee E05 Next Meeting:, June 23-26, 2014, June Committee, Toronto, Ontario, Canada, Technical Contact:, Joe Zicherman, Fire Cause Analysis, Berkeley, Calif., Phone: 510-649-1300; zicherman46@gmail.com, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9635
-
A wildland-urban interface is a transitional zone between unoccupied land and human development. There are currently more than 40 million homes located within WUI areas throughout the United States. A proposed new ASTM standard will be used to alleviate the issue of fire conditions that exist due to eaves and other projections in structures that exist in WUI areas. ASTM WK37414, Test Method for…, ASTM Committee E05 Next Meeting:, June 23-26, 2014, June Committee Week, Toronto, Ontario, Canada, Technical Contact:, John Simontacchi, Firefree Coatings Inc., San Rafael, Calif., Phone: 415-459-6488; jsimontacchi@firefree.com , ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9529
-
Rotational viscometry is an easily used tool for determining the viscosity of fluids, including paints, petroleum products and polymer solutions. While standards often make use of rotational viscometry, a procedure for calibrating or validating the measurement is not always part of the standard, which could lead to results that differ from one laboratory to another. A proposed user viscosity…, ASTM Committee E37 Next Meeting:, March 14, 2014, ASTM International Headquarters, West Conshohocken, Pa., Technical Contact:, Roger Blaine, Corvallis, Ore., Phone: 302-559-6827; roger.l.blaine@gmail.com, ASTM Staff Contact:, Tom O'Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9493
-
The headspace in domestic wastewater collection and treatment systems is a severe environment that can impact even high performance protective coatings. A proposed new ASTM International standard covers an apparatus and set of procedures that are used to create and maintain a simulated sewer headspace environment to be used to test potential coatings. ASTM WK33537 , Practice for Operating the…, ASTM Committee G01 Next Meeting:, Nov. 12-14, 2013, November Committee Week, Jacksonville, Fla., Technical Contact:, Vaughn O’Dea, Tnemec Co. Inc., Kansas City, Mo., Phone: 816-519-2267; odea@tnemec.com , ASTM Staff Contact:, Jennifer Rodgers, Phone: 610-832-9694; jrodgers@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9438
-
ASTM International Committee G01 on Corrosion of Metals has an ongoing commitment to help the oil field industries adopt and use state-of-the-art techniques to control corrosion. As part of this commitment, Subcommittee G01.05 on Laboratory Corrosion Tests has approved ASTM G205 , Guide for Determining Corrosivity of Crude Oils. ASTM G205 is the result of collaboration among members of Task Group…, ASTM Committee G01 Next Meeting:, Nov. 13-15, November Committee Week, Atlanta, Ga., Technical Contact:, Sankara Papavinasam, Ph.D., CanmetMATERIALS, Hamilton, Ontario, Canada, Phone: 613-947-4603; spapavin@nrcan.gc.ca, ASTM Staff Contact:, Jennifer Rodgers, Phone: 610-832-9694; jrodgers@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9297
-
A proposed new ASTM International standard will detail a multilevel approach for performing above- and below-ground inspection of transmission poles and lattice towers in the field. ASTM WK35986, Test Method for Field Inspection of Transmission Poles and Lattice Towers, will be used by utilities to provide tools for maintenance departments that inspect and repair transmission structures. ASTM…