Search
Advanced search
Filter by category
Filter by committee
Search results
-
Knowing that the floor beneath you is safe is something most of us take for granted. A proposed new ASTM International standard will help people who have to think about, and test for, floor safety all the time. The proposed new standard is ASTM WK47030 , Practice for Evaluating Concrete Floor Systems to Receive Resilient Flooring. The World Floor Covering Association and the Floor Covering…, ASTM Committee F06 Next Meeting:, Nov. 12-13, November Committee Week, New Orleans, La., Technical Contact:, George Donnelly, George Donnelly Testing and Inspections, Hot Springs, Ark., tel +1.501.915.0626; info@moisturetesting.com, ASTM Staff Contact:, Stephen Mawn, tel +1.610.832.9726; smawn@astm.org, ASTM PR Contact:, Barbara Schindler, tel +1.610.832.9603; bschindl@astm.org Release #9706
-
Taking a tape-lift sample is one of the main practices used by indoor environmental quality investigators for detecting whether mold structures (for example, spores and hyphae) have either settled onto or colonized the surface. Despite the popularity of the method, there can be significant inconsistency in how tape lifts are collected. A new ASTM standard, ASTM D7910 , Practice for the Collection…, ASTM Committee D22 Next Meeting:, Oct. 5-8, 2014, October Committee Week, New Orleans, La., Technical Contact:, John M. Neville, Ph.D., Bureau Veritas North America Inc., Novi, Mich., Phone: 248-344-3042; john.neville@us.bureauveritas.com, ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9655
-
A new standard, ASTM D7886 , Practice for Asbestos Exposure Assessments for Repetitive Maintenance and Installation Tasks, will aid those testing asbestos exposures by quantifying such exposure levels. Regulations set forth by the U.S. Occupational Safety and Health Administration require that worker exposure to asbestos be determined with a “high level of certainty.” “ASTM D7886 overcomes the…, ASTM Committee D22 Next Meeting:, Oct. 5-8, 2014, October Committee Week, New Orleans, La., Technical Contact:, Andrew F. Oberta, MPS, CIH, The Environmental Consultancy, Austin, Texas, Phone: 512-266-1368; andyobe@aol.com , ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9639
-
Gaseous hydrogen fluoride is a harsh respiratory irritant; the inhalation of hydrofluoric acid mists causes severe lung damage in exposed workers. A proposed new ASTM standard, WK38734 , Test Method for the Determination of Particulate Fluorides and Hydrofluoric Acid Using Filter Sampling and Suppressed Ion Chromatography, will be used to prevent overexposure of hydrofluoric acid/hydrogen…, ASTM Committee D22 Next Meeting:, Oct. 5-8, 2014, October Committee Week, New Orleans, La., Technical Contact:, Dietmar Breuer, IFA, Sankt Augustin, Germany, Phone: +49 (0) 2241 231-2533; dietmar.breuer@dguv.de , ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9585
-
While monitoring air quality is important in many situations, a variety of different quantitative passive samplers are available for such work. A proposed new ASTM standard, ASTM WK45755 , Guide for Selection of Quantitative Passive Samplers for Volatile Organic Compounds in Air, will help users decide which air sampler type will best suit their needs. ASTM WK45755 will cover issues such as the…, ASTM Committee D22 Next Meeting:, Oct. 5-8, 2014, October Committee Week, New Orleans, La., Technical Contact:, Nicola Watson, Markes International, Loveland, Ohio, Phone: 513-488-6161; nwatson@markes.com , ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9578
-
For more than 100 years, cork tile has been commonly used as a floor and wall covering for residential and commercial use. A new ASTM International standard, ASTM F3008 , Specification for Cork Floor Tile, specifies requirements for cork floor coverings made from agglomerated composition cork supplied in tile form, which is designed to be used with a factory finish or an in situ finish, or both.…, ASTM Committee F06 Next Meeting:, May 7-8, 2014, Clearwater, Fla., Technical Contact:, Christopher Capobianco, Spartan Surfaces, Patchogue, N.Y., Phone: 631-275-6494; christopher@spartansurfaces.com, ASTM Staff Contact:, Stephen Mawn, Phone: 610-832-9726; smawn@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9523
-
A new ASTM International standard is focused exclusively on testing soil for asbestos. ASTM D7521 , Test Method for Determination of Asbestos in Soil, was developed by Subcommittee D22.07 on Sampling and Analysis of Asbestos , part of ASTM International Committee D22 on Air Quality . According to Alan Segrave, division manager, laboratory services, Bureau Veritas, and an ASTM D22 member, many…, ASTM Committee D22 Next Meeting:, April 14-17, April Committee Week, Indianapolis, Ind., Technical Contact:, Alan M. Segrave, Bureau Veritas North America Inc., Kennesaw, Ga., Phone: 770-590-6706; alan.segrave@us.bureauveritas.com, ASTM Staff Contact:, David Bradley, Phone: 610-832-9681; dbradley@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9295
-
A recently published ASTM International standard covers a new type of resilient flooring tile product based on a polyester binder. ASTM F2982 , Specification for Polyester Composition Floor Tile, was developed by Subcommittee F06.80 on Specifications , part of ASTM International Committee F06 on Resilient Floor Coverings . “ ASTM F2982 sets forth an explicit set of compositional and performance…, ASTM Committee F06 Next Meeting:, May 22-23, 2013, May Committee Week, Indianapolis, Ind., Technical Contact:, Thomas Erisman, Armstrong World Industries, Lancaster, Pa., Phone: 717-396-5354; tcerisman@armstrong.com, ASTM Staff Contact:, Stephen Mawn, Phone: 610-832-9726; smawn@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9271
-
A newly approved standard, ASTM D7338 , Guide for the Assessment of Fungal Growth in Buildings, has been developed to provide a go-to reference for anyone testing for mold in buildings. The new standard was developed by Subcommittee D22.08 on Sampling and Analysis of Mold, part of ASTM International Committee D22 on Air Quality. “The lack of consensus standards in the fungal sampling and analysis…, ASTM Committee D22 Next Meeting:, April 10-13, April Committee Week, Anaheim, Calif., Technical Contact:, Lisa Rogers, Mycometer, Inc., Tampa, Fla., Phone: 813-831-6511; lrogers@mycometer.com, ASTM Staff Contact:, David Bradley, Phone: 610-832-9681; dbradley@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8788
-
Non-destructive moisture meters are now widely used in determining moisture levels in concrete, gypsum concrete and other types of floor slabs. A new ASTM International standard qualifies the types of meter suitable for this purpose and provides guidelines for how, where and when such moisture meters are used and what limitations exist. The new standard, ASTM F2659 , Guide for Preliminary…, ASTM Committee F06 Next Meeting:, Nov. 10-11, New Orleans, La., Technical Contact:, Sean Fallon, Dublin, Ireland, Phone: +011-353-1-285-1861; seanfallon@ireland.com, ASTM Staff Contact:, Stephen Mawn, Phone: 610-832-9726; smawn@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #870/Oct2010