Search
Advanced search
Filter by category
Filter by committee
Search results
-
In many testing laboratories, it can be necessary to qualify a new test method, instrument or lab itself with respect to one or more performance characteristics. One such key characteristic is bias, or mutual agreement of average test results run on the same material. A proposed ASTM standard will aid in the determination of bias equivalency. ASTM WK37659 , Guide for Testing for Bias Equivalency…
-
For several years, ASTM International Committee E11 on Quality and Statistics has been preserving military sampling standards no longer supported by the U.S. Department of Defense. The latest ASTM standard to emerge from this program is ASTM E2819 , Practice for Single- and Multi-Level Continuous Sampling of a Stream of Product by Attributes Indexed by AQL. “The reason for preserving military…
-
Interested parties are invited to join in the development of a new proposed standard being developed by ASTM International Committee E11 on Quality and Statistics . ASTM WK32565 , Guide for the Use of Non-Parametric Statistical Methods, is under the jurisdiction of Subcommittee E11.10 on Sampling/Statistics . According to Stephen Luko, statistician, Hamilton Sundstrand, Shared Engineering…, ASTM Committee E11 Next Meeting:, Oct. 26-28, 2011, ASTM International Headquarters, West Conshohocken, Pa., Technical Contact:, Stephen N. Luko, Hamilton Sunstrand, Shared Engineering Services, Windsor Locks, Conn., Phone: 860-654-3447; stephen.luko@hs.utc.com, ASTM Staff Contact:, Christine Sierk, Phone: 610-832-9728; csierk@astm.org Release #8978
-
Rheologists are encouraged to join in the development of a proposed new practice that will help standardize calibration of rotational rheometers to obtain accurate normal force measurements. ASTM WK33687 , Practice for Normal Force Calibration for Rotational Rheometers, is being developed by Subcommittee E37.08 on Rheology , part of ASTM International Committee E37 on Thermal Measurements . The…, ASTM Committee E37 Next Meeting:, Aug. 10-11, in conjunction with the North American Thermal Analysis Society Annual Conference, Des Moines, Iowa, Technical Contact:, Kenneth Aniunioh, Shimadzu Scientific Instruments, Laurel, Md., Phone: 864-633-7690; kenebaano@yahoo.com, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8923
-
Laboratories that have the ability to analyze titanium and titanium alloys by spark-atomic emission spectrometry or glow discharge-AES are currently being sought to participate in an interlaboratory study for a proposed new standard. ASTM WK25738 , Test Method for Analysis of Titanium and Titanium Alloys by Spark-Atomic Emission/Glow Discharge-Atomic Emission Spectrometry, is currently being…, ASTM Committee E01 Next Meeting:, May 15-18, 2011, May Committee Week, Anaheim, Calif., Technical Contact:, Kevin VonScio, Perryman Co., Houston, Pa., Phone: 724-746-9390; kvonscio@perrymanco.com, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8855
-
Measurement systems analysis is an important topic in statistics and quality for engineering, manufacturing, laboratory practice and business process applications. A new ASTM International standard, ASTM E2782 , Guide for Measurement Systems Analysis (MSA), covers many core issues of MSA. ASTM E2782 was developed by Subcommittee E11.20 on Test Method Evaluation and Quality Control, under the…
-
Trona, or sodium sesquicarbonate, is a fine mineral powder that has proven to be effective at removing acid gases from air emissions. While trona can be a useful component of air pollution control systems, it can be difficult to handle, particularly when moisture is present. A proposed new ASTM standard will present a repeatable, precise and accurate test method for analyzing moisture levels in…, ASTM Committee E01 Next Meeting:, Nov. 14-17, November Committee Week, San Antonio, Texas, Technical Contact: J, ames D. Phillip, Solvay Chemicals Inc, Green River, Wyo., Phone: 307-872-6519; jim.phillip@solvay.com, ASTM Staff Contact:, Thomas O'Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8608
-
The ASTM International Proficiency Testing Center is pleased to offer a 2010 Proficiency Testing Program on Thermal Analyses of Plastics (TAP) to laboratories who need a statistical quality assurance tool that will enable them to improve and maintain a high level of performance in conducting ASTM Differential Scanning Calorimetry (DSC), Oxidative-Induction Time (OIT) by Differential Scanning…, ASTM D3418, , Standard Test Method for Transition Temperatures and Enthalpies of Fusion and Crystallization of Polymers by Differential Scanning Calorimetry (DSC);, ASTM D3850, , Standard Test Method for Rapid Thermal Degradation of Solid Electrical Insulating Materials By Thermogravimetric Method (TGA); and, ASTM D3895, , Standard Test Method for Oxidative-Induction Time of Polyolefins by Differential Scanning Calorimetry. For each test trial, laboratory participants receive two sample materials along with interactive electronic data report forms and test instructions. Using the specified ASTM program tests, participating laboratories conduct the tests of their choice that they routinely run. Upon completion of…
-
Test Method Covers Inductively Coupled Plasma Atomic Emission Spectrometry, A new ASTM International standard will help users properly prepare and analyze various nickel-based alloy samples by inductively coupled plasma emission spectrometry. The standard, ASTM E2594 , Test Method for Analysis of Nickel Alloys by Inductively Coupled Plasma Atomic Emission Spectrometry (Performance-Based Method), will assist users in preparing sample and calibration solutions and with…
-
Advancing gas analysis technology is leading to the development of a proposed new ASTM International standard, WK22331 , Test Method for Simultaneous Determination of Oxygen, Nitrogen and Hydrogen in Titanium and Titanium Alloys by the Inert Gas Fusion Technique. Analyzers are now available that can simultaneously test titanium and titanium alloys for oxygen, nitrogen and hydrogen. This…