Search
Advanced search
Filter by category
Filter by committee
Search results
-
A new ASTM standard consolidates six current standards on structural fasteners. With hundreds of millions of fasteners produced to ASTM specifications each year, industry will benefit from the streamlined approach provided by the new ASTM standard ( F3125 : Specification for High Strength Structural Bolts, Steel and Alloy Steel, Heat Treated, 120 ksi (830 MPa) and150 ksi (1040 MPa) Minimum…, ASTM Committee F16 Next Meeting:, May 17-19, 2015, May committee week, Anaheim, Calif., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Chad Larson, LeJeune Bolt Co., Burnsville, Minn., tel +1.952.890.7700; clarson@lejeunebolt.com, ASTM Staff Contact:, Jennifer Rodgers, tel +1.610.832.9694; jrodgers@astm.org Release #9785 ###
-
Maybe you haven’t given much thought to the growth of interlaminar cracks, or cracks in between layers, in laminated composite materials. Perhaps you should though, because such materials are everywhere and interlaminar cracks can cause serious damage to many types of structures and products, from sports equipment to spacecraft. This is why a new ASTM standard, D7905/D7905M , Test Method for…, Technical Contact:, Barry D. Davidson, Ph.D. Syracuse University, Syracuse, N.Y., tel +1.315.443.4201; bddavids@syr.edu, ASTM Staff Contact:, Ashley Wiand, tel +1.610.832.9551; awiand@astm.org, ASTM PR Contact:, Barbara Schindler, tel +1.610.832.9603; bschindl@astm.org Release #9724
-
Adopted in 2005, Chapter 7A of the California Building Code describes provisions for attic vents for new construction in wildfire-prone areas. While the California code notes that attic vents should resist the intrusion of embers and flames, there had not been a standard to evaluate such intrusion. A new standard, ASTM E2886/E2886M , Test Method for Evaluating the Ability of Exterior Vents to…, ASTM Committee E05 Next Meeting:, Dec. 8-11, 2014, December Committee, New Orleans, La., Technical Contact:, Stephen Quarles, Insurance Institute for Business and Home Safety, Richburg, S.C., Phone: 803-789-4209; squarles@ibhs.org , ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9617
-
A proposed new ASTM International test method will describe a single specific integration technique that can be applied to tabulated digital measurement data acquired by modern instrumentation used for studying weathering and durability. ASTM WK45298 , Test Method for the Integration of Digital Spectral Data for Weathering and Durability Applications, is being developed by Subcommittee G03.09 on…, ASTM Committee G03 Next Meeting:, Jan. 25-27, 2015, January Committee Week, New Orleans, La., Technical Contact:, Aron Habte, National Renewable Energy Laboratory, Golden, Colo., Phone: 303-384-6389; aron.habte@nrel.gov , ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9637
-
A proposed new ASTM International standard is being developed for mounting plastic pipe and tube in the Steiner tunnel furnace. The draft procedure will help determine the fire-related properties of the pipe and tube in accordance with ASTM E84, Test Method for Surface Burning Characteristics of Building Materials. ASTM WK44535 , Practice for Mounting of Plastic Pipe, Plastic Tubing, Plastic Pipe…, ASTM Committee E05 Next Meeting:, June 23-26, 2014, June Committee, Toronto, Ontario, Canada, Technical Contact:, Joe Zicherman, Fire Cause Analysis, Berkeley, Calif., Phone: 510-649-1300; zicherman46@gmail.com, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9635
-
A wildland-urban interface is a transitional zone between unoccupied land and human development. There are currently more than 40 million homes located within WUI areas throughout the United States. A proposed new ASTM standard will be used to alleviate the issue of fire conditions that exist due to eaves and other projections in structures that exist in WUI areas. ASTM WK37414, Test Method for…, ASTM Committee E05 Next Meeting:, June 23-26, 2014, June Committee Week, Toronto, Ontario, Canada, Technical Contact:, John Simontacchi, Firefree Coatings Inc., San Rafael, Calif., Phone: 415-459-6488; jsimontacchi@firefree.com , ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9529
-
A new ASTM International standard fills an industry need for damage resistance testing of sandwich constructions, a common composite structural configuration. ASTM D7766/D7766M , Practice for Damage Resistance Testing of Sandwich Constructions, was developed by Subcommittee D30.09 on Sandwich Construction , part of ASTM International Committee D30 on Composite Materials . “ASTM D7766/D7766M will…, Technical Contact:, Adam J. Sawicki, Boeing Co., Philadelphia, Pa., Phone: 610-591-2807; adam.j.sawicki@boeing.com, ASTM Staff Contact:, Ashley Wiand, Phone: 610-832-9551; awiand@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9195
-
A proposed new ASTM International standard will improve the accuracy and usefulness of radiometry-related uncertainty estimates in a wide range of fast developing solar renewable energy applications, such as system performance and acceptance testing, resource assessment and solar energy system design engineering. The proposed standard, ASTM WK36479 , Practice for Uncertainty Evaluation of…
-
A new test method is the latest in a series of ASTM International standards being developed to address the protection of exterior portions of structures during fires. The new standard, ASTM E2726/E2726M , Test Method for Evaluating the Fire-Test-Response of Deck Structures to Burning Brands, is being developed by Subcommittee E05.14 on External Fire Exposures , part of ASTM International…
-
Manufacturers of solar radiometers and testing laboratories for solar energy, materials and durability testing will be among the primary users of a new ASTM International standard that outlines procedures using indoor test methods to calibrate radiometers with dissimilar detectors. The new standard, ASTM G207 , Test Method for Indoor Transfer of Calibration from Reference to Field Pyranometers,…, ASTM Committee G03 Next Meeting:, Jan. 29-31, 2012, January Committee Week, Atlanta, Ga., Technical Contact:, Daryl Myers, National Renewable Energy Laboratory, Golden, Colo., Phone: 303-384-6768; daryl.myers@nrel.gov, ASTM Staff Contact:, Jeff Adkins, Phone: 610-832-9738; jadkins@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8965