Search
Advanced search
Filter by category
Filter by committee
Search results
-
ASTM International has approved a new guide that will help environmental professionals who want to assess or repurpose landfills and chemically impacted sites. ASTM Committee E50 on Environmental Assessment, Risk Management and Corrective Action developed the new standard, soon to be published as E3033, Guide for Beneficial Use of Landfills and Chemically Impacted Sites. “The committee became…, ASTM Committee E50 on Environmental Assessment, Risk Management and Corrective Action Next Meeting:, April 11-14, 2016, April Committee Week, San Antonio, TX. , Media Inquiries:, Dan Bergels, tel +1.610.832.9602; dbergels@astm.org , Technical Contact:, Marty Rowland, NYC Department of Parks & Recreation, New York, NY., tel +1.718.6922; Marty.Rowland@parks.nyc.gov , ASTM Staff Contact:, Kathleen Chalfin, tel +1.610.832.9717; kchalfin@astm.org Release #10023
-
ASTM International’s Fire Committee ( E05 ) is developing a standard that will test fire resistance of wooden utility poles. Utility companies and coating and treatment manufacturers will use the standard to test new products that could protect the poles. “Utility poles are frequently exposed to high intensity wildfires throughout the world,” says ASTM member Brent M. Pickett, Ph.D. “If these…, ASTM Committee E05 on Fire Next Meeting:, June 27-30, 2016, June Committee Week, Chicago, Ill., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Brent M. Pickett, Ph.D., Western Fire Center Inc., Kelso, Wash., tel +1.360.423.1400; brent@westernfire.com , ASTM Staff Contact:, Thomas O’Toole, tel +1.610.832.9739; totoole@astm.org Release #9989
-
ASTM International, the American Society for Composites, Syracuse University, the University of Utah, and the National Institute of Aerospace will jointly support the 31st Annual Technical Conference of the American Society for Composites (Sept. 19-21) and the ASTM Committee on Composite Materials (D30) meeting (Sept. 21-22). Both events will be in Williamsburg, Virginia. Information on the…, Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Ronald Krueger, National Institute of Aerospace, Hampton, Va., tel +1.757.864.3482; rkrueger@nianet.org , ASTM Staff Contact:, Krista Robbins, tel +1.610.832.9689; krobbins@astm.org Release #9969
-
A new ASTM International guide will help evaluate unwanted moisture in commercial buildings. The standard provides two questionnaires that assess elevated moisture and moisture-conducive conditions. The standard has been published as E3026 , Guide for Readily Observable Moisture Affected Materials and Conditions Conducive to Elevated Moisture in Commercial Buildings: Visual Moisture Assessment…, ASTM Committee E50 on Environmental Assessment, Risk Management and Corrective Action Next Meeting:, Oct. 26-29, 2015, October Committee Week, Tampa, Fla., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Jim E. Bartlett, EMG, Owings Mills, Md., tel +1.800.626.3332 ext. 7609; jbartlett@emgcorp.com, ASTM Staff Contact:, Kathleen Chalfin, tel +1.610.832.9717; kchalfin@astm.org Release #9902
-
Maybe you haven’t given much thought to the growth of interlaminar cracks, or cracks in between layers, in laminated composite materials. Perhaps you should though, because such materials are everywhere and interlaminar cracks can cause serious damage to many types of structures and products, from sports equipment to spacecraft. This is why a new ASTM standard, D7905/D7905M , Test Method for…, Technical Contact:, Barry D. Davidson, Ph.D. Syracuse University, Syracuse, N.Y., tel +1.315.443.4201; bddavids@syr.edu, ASTM Staff Contact:, Ashley Wiand, tel +1.610.832.9551; awiand@astm.org, ASTM PR Contact:, Barbara Schindler, tel +1.610.832.9603; bschindl@astm.org Release #9724
-
Adopted in 2005, Chapter 7A of the California Building Code describes provisions for attic vents for new construction in wildfire-prone areas. While the California code notes that attic vents should resist the intrusion of embers and flames, there had not been a standard to evaluate such intrusion. A new standard, ASTM E2886/E2886M , Test Method for Evaluating the Ability of Exterior Vents to…, ASTM Committee E05 Next Meeting:, Dec. 8-11, 2014, December Committee, New Orleans, La., Technical Contact:, Stephen Quarles, Insurance Institute for Business and Home Safety, Richburg, S.C., Phone: 803-789-4209; squarles@ibhs.org , ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9617
-
A proposed new ASTM International standard is being developed for mounting plastic pipe and tube in the Steiner tunnel furnace. The draft procedure will help determine the fire-related properties of the pipe and tube in accordance with ASTM E84, Test Method for Surface Burning Characteristics of Building Materials. ASTM WK44535 , Practice for Mounting of Plastic Pipe, Plastic Tubing, Plastic Pipe…, ASTM Committee E05 Next Meeting:, June 23-26, 2014, June Committee, Toronto, Ontario, Canada, Technical Contact:, Joe Zicherman, Fire Cause Analysis, Berkeley, Calif., Phone: 510-649-1300; zicherman46@gmail.com, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9635
-
On Dec. 30, 2013, the U.S. Environmental Protection Agency published a final rule that incorporates the latest version of ASTM International standard E1527-13 , Practice for Environmental Site Assessments: Phase I Environmental Site Assessment Process, in the performance of all appropriate inquiries when conducting environmental site assessments. The EPA’s Final Rule, which went into effect upon…, ASTM Committee E50 Next Meeting:, April 7-10, 2014, April Committee Week, Toronto, Ontario, Canada, Technical Contact:, Julie Kilgore, Wasatch Environmental Inc., Salt Lake City, Utah, Phone: 801-972-8400; jk@wasatch-environmental.com, ASTM Staff Contact:, Kathleen McClung, Phone: 610-832-9717; kmcclung@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9542
-
ASTM International approved a new standard on applying greener best management practices to site assessment and cleanup projects. ASTM E2893 , Guide for Greener Cleanups, was approved Sept. 15 by Subcommittee E50.04 on Corrective Action , part of ASTM International Committee E50 on Environmental Assessment, Risk Management and Corrective Action . “Greener cleanups protect human health and the…, ASTM Committee E50 Next Meeting:, April 7-10, 2014, April Committee Week, Toronto, Ontario, Canada, Technical Contact:, John A. Simon, Gnarus Advisors LLC, Arlington, Va., Phone: 202-505-1906; jsimon@gnarusllc.com , ASTM Staff Contact:, Kathleen McClung, Phone: 610-832-9717; kmcclung@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9525
-
A wildland-urban interface is a transitional zone between unoccupied land and human development. There are currently more than 40 million homes located within WUI areas throughout the United States. A proposed new ASTM standard will be used to alleviate the issue of fire conditions that exist due to eaves and other projections in structures that exist in WUI areas. ASTM WK37414, Test Method for…, ASTM Committee E05 Next Meeting:, June 23-26, 2014, June Committee Week, Toronto, Ontario, Canada, Technical Contact:, John Simontacchi, Firefree Coatings Inc., San Rafael, Calif., Phone: 415-459-6488; jsimontacchi@firefree.com , ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9529