Search
Advanced search
Filter by category
Filter by committee
Search results
-
A proposed ASTM standard could help improve workplace safety by describing proximity alarm systems that can be used to prevent cranes, utility trucks, and other equipment from encroaching inside OSHA minimum approach distances and contacting high-voltage power lines. The standard would be most useful to the construction industry, but it could also help in firefighting, drilling, mining,…, ASTM Committee F18 on Electrical Protective Equipment for Workers Next Meeting:, Oct. 4-7, 2015, Las Vegas, Nev., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Lance Burney, Sigalarm, Sanford, Fla., tel +1.407.321.0722; lance@sigalarminc.com , ASTM Staff Contact:, Kevin Shanahan, tel +1.610.832.9737; kshanahan@astm.org Release #9903
-
A proposed new ASTM standard will provide a lab test to determine how various types of oil will interact with water in oil spill situations. Information gleaned from such testing will ultimately lead to more effective oil spill recovery. All interested parties are welcome to join in the ongoing development of the standard ( WK41247 , Test Method for the Evaluation of the Stability of Water-in-Oil…, ASTM Committee F20 on Hazardous Substances and Oil Spill Response Next Meeting:, Oct. 27-28, 2015, October committee week, Tampa, Fla., Technical Contact:, Mervin Fingas, Edmonton, Alberta, Canada, tel +1.780.989.6059; fingasmerv@shaw.ca, ASTM Staff Contact:, Jeffrey Adkins, tel +1.610.832.9738; jadkins@astm.org, ASTM PR Contact:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org Release #9772
-
Maybe you haven’t given much thought to the growth of interlaminar cracks, or cracks in between layers, in laminated composite materials. Perhaps you should though, because such materials are everywhere and interlaminar cracks can cause serious damage to many types of structures and products, from sports equipment to spacecraft. This is why a new ASTM standard, D7905/D7905M , Test Method for…, Technical Contact:, Barry D. Davidson, Ph.D. Syracuse University, Syracuse, N.Y., tel +1.315.443.4201; bddavids@syr.edu, ASTM Staff Contact:, Ashley Wiand, tel +1.610.832.9551; awiand@astm.org, ASTM PR Contact:, Barbara Schindler, tel +1.610.832.9603; bschindl@astm.org Release #9724
-
Since 2009, the National Fire Protection Association has required arc rated gloves in its NFPA70E, Standard for Electrical Safety in the Workplace. A new ASTM standard will now provide arc rating thermal protective values for gloves, which will allow more gloves to be used inside an arc flash zone when there is no shock hazard. The new standard, ASTM F2675/F2675M , Test Method for Determining Arc…, ASTM Committee F18 Next Meeting:, Oct. 20-23, 2013, Charleston, S.C., Technical Contact:, Hugh Hoagland, ArcWear, Louisville, Ky., Phone: 502-832-9737; hugh@arcwear.com , ASTM Staff Contact:, Kevin Shanahan, Phone: 610-832-9737, kshanahan@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9469
-
Coated fabric products used for oil spill response procedures can deteriorate when stored for long periods of time. A proposed new ASTM standard will provide a nondestructive test for stored equipment to be evaluated for continued suitability over time. ASTM WK37298 , Test Method for Determining Storage Life of Coated Fabric Products, is being developed by Subcommittee F20.11 on Control , part of…, ASTM Committee F20 Next Meeting:, Oct. 23-24, 2012, October Committee Week, Atlanta, Ga., Technical Contact:, Peter Lane, Applied Fabric Technologies Inc., Applied Fabric Technologies Inc., Morris Skimmers International LLC, Orchard Park, N.Y., Phone: 716-662-0632; lane@afti.com, ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9310
-
ASTM International Committee F20 on Hazardous Substances and Oil Spill Response has approved several standards for in-situ burning. The latest proposed standard on this subject, ASTM WK37324 , Guide for Evaluation of In-Situ Burning Effectiveness, is currently being developed by Subcommittee F20.15 on In-Situ Burning . In-situ burning is a controlled burning, at the spill location, of oil that…, ASTM Committee F20 Next Meeting:, Oct. 23-24, 2012, October Committee Week, Atlanta, Ga., Technical Contact:, Steve Potter, SL Ross Environmental Research Ltd., Ottawa, Ontario, Canada, Phone: 613-232-1564; steve@slross.com, ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-932-9738; jadkins@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9294
-
A new ASTM International standard fills an industry need for damage resistance testing of sandwich constructions, a common composite structural configuration. ASTM D7766/D7766M , Practice for Damage Resistance Testing of Sandwich Constructions, was developed by Subcommittee D30.09 on Sandwich Construction , part of ASTM International Committee D30 on Composite Materials . “ASTM D7766/D7766M will…, Technical Contact:, Adam J. Sawicki, Boeing Co., Philadelphia, Pa., Phone: 610-591-2807; adam.j.sawicki@boeing.com, ASTM Staff Contact:, Ashley Wiand, Phone: 610-832-9551; awiand@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9195
-
A proposed new standard being developed by ASTM International Committee F18 on Electrical Protective Equipment for Workers will provide guidance to assist in the required testing of live-line tools. ASTM WK33590 , Guide for In-Service Inspection, Maintenance and Electrical Testing of Insulating Tools (Fiberglass-Reinforced Plastic (FPR) and Wooden Live-Line Tools), is under the jurisdiction of…
-
A new ASTM International standard will be a useful document for vendors, buyers and regulators in determining the applicability of different types of booms to be used for oil spill response. ASTM F2683 , Guide for Selection of Booms for Oil Spill Response, was developed by Subcommittee F20.11 on Control , part of ASTM International Committee F20 on Hazardous Substances and Oil Spill Response .…
-
A new ASTM International standard will answer industry’s need for determination of fatigue properties of open-hole composite laminates. ASTM D7615/D7615M , Practice for Open-Hole Fatigue Response of Polymer Matrix Composite Laminates, was developed by Subcommittee D30.05 on Structural Test Methods , part of ASTM International Committee D30 on Composite Materials . The purpose of ASTM D7615/D7615M…, ASTM Committee D30 Next Meeting:, Oct. 17-19, 2011, in conjunction with the Society for the Advancement of Material and Process Engineering, Fort Worth, Texas, Technical Contact:, Mark Chris, Bell Helicopter Textron, Inc., Dallas, Texas, Phone: 817-280-872; mchris@bellhelicopter.textron.com, ASTM Staff Contact:, Ashley Wiand, Phone: 610-832-9551; awiand@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8914