Search
Advanced search
Filter by category
Filter by committee
Search results
-
Activated carbon is processed to have small, low-volume pores that increase the surface area available for adsorption. It has applications in the medical, environmental and energy realms, among others. Since 1962, ASTM International Committee D28 on Activated Carbon has developed standards that play a pre-eminent role in how activated carbon is used. A D28 subcommittee, D28.02 on Liquid Phase…, WK47401, Xylenol Orange Dye, The xylenol orange dye test is a way to determine the relative adsorption rate of unused or reactivated carbons by adsorption of xylenol orange from aqueous solution. This is an important means for deciding which type of activated carbon to use to a specific water treatment application. “Activated carbon performance can roughly be defined as a combination of the ability to adsorb a particular…, WK47421, Particle Size Distribution, Mercury flue gas, home water filters and potable water treatment are the main applications in which powdered and fine mesh carbons are used. A proposed new test method will describe how a laser light scattering technique can determine the particle size distribution of fine mesh activated carbon. ASTM member Neal Megonnell, vice president, sales and marketing, Haycarb USA, says the proposed test…, ASTM Committee D28 Next Meeting:, April 27, April Committee Week, Anaheim, Calif., Technical Contact:, (WK47401) Adam Redding, Ph.D., Evoqua Water Technologies LLC, Northwest, Pa., tel +1.724.719.0805; adam.redding@evoqua.com and (WK47421) Neal E. Megonnell, Haycarb USA, Pittsburgh, Pa., tel +1.412.709.7487; neal@haycarbusa.com, ASTM Staff Contact:, Kelly Paul, tel +1.610.832.9745; kpaul@astm.org, ASTM PR Contact:, Barbara Schindler, tel +1.610.832.9603; bschindl@astm.org Release #9731
-
Since 2009, the National Fire Protection Association has required arc rated gloves in its NFPA70E, Standard for Electrical Safety in the Workplace. A new ASTM standard will now provide arc rating thermal protective values for gloves, which will allow more gloves to be used inside an arc flash zone when there is no shock hazard. The new standard, ASTM F2675/F2675M , Test Method for Determining Arc…, ASTM Committee F18 Next Meeting:, Oct. 20-23, 2013, Charleston, S.C., Technical Contact:, Hugh Hoagland, ArcWear, Louisville, Ky., Phone: 502-832-9737; hugh@arcwear.com , ASTM Staff Contact:, Kevin Shanahan, Phone: 610-832-9737, kshanahan@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9469
-
A proposed new standard being developed by ASTM International Committee F18 on Electrical Protective Equipment for Workers will provide guidance to assist in the required testing of live-line tools. ASTM WK33590 , Guide for In-Service Inspection, Maintenance and Electrical Testing of Insulating Tools (Fiberglass-Reinforced Plastic (FPR) and Wooden Live-Line Tools), is under the jurisdiction of…
-
Users of standards involving kinetic parameters need reference materials to qualify individual laboratories and to validate procedures and software. A new ASTM International standard will provide such parameters to accommodate apparatus configurations and kinetic models. ASTM E2781 , Practice for Evaluation of Methods for Determination of Kinetic Parameters by Thermal Analysis, was developed by…, ASTM Committee E27 Next Meeting:, Nov. 15-17, November Committee Week, Tampa, Fla., Technical Contact:, Roger Blaine, Corvallis, Ore., Phone:, 302-559-6827; roger.l.blaine@gmail.com ASTM Staff Contact:, Scott Orthey, Phone: 610-832-9730; sorthey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8893
-
Proposed ASTM Kinetic Parameters Standard Being Developed by Hazard Potential of Chemicals CommitteeA proposed new standard being developed by ASTM International Committee E27 on Hazard Potential of Chemicals will provide needed reference materials for instruments, applications and software used for the evaluation of kinetic data used for hazard evaluation. The proposed new standard, ASTM WK27880 , Practice for Evaluation of Methods for Determination of Kinetic Parameters by Thermal Analysis,…, ASTM Committee E27 Next Meeting:, Nov. 15-17, November Committee Week, Tampa, Fla., Technical Contact:, Roger Blaine, Corvallis, Ore., Phone: 302-559-6827; roger.l.blaine@gmail.com, ASTM Staff Contact:, Scott Orthey, Phone: 610-832-9730; sorthey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8611
-
Mercury emissions from flue gases in coal-fired power plants are a large source of atmospheric mercury in the United States, but no standard for determination of mercury adsorption currently exists. One promising method of controlling these emissions involves the injection of powdered activated carbon into the flue gas. A proposed new ASTM International standard would evaluate the performance of…
-
Arc protective blankets are used in many electrical applications to protect workers who are stationed near energized electrical parts. While these blankets have been used for years, there have been no testing criteria for their evaluation. A new ASTM International standard will be used to determine the effectiveness of arc protective blankets in suppressing the combined effect of an arc flash and…
-
A new ASTM International standard, F 2621 , Practice for Determining Response Characteristics and Design Integrity of Arc Related Finished Products in an Electric Arc Exposure, is the latest in a series of standards developed by Subcommittee F18.65 on Wearing Apparel to reduce the number of fatalities and injuries caused by electric arcs. ASTM Practice F 2621 provides procedural guidelines for…
-
A process hazard analysis prior to the startup of a chemical processing facility is essential to prevent catastrophic incidents due to thermal runaway reactions. A proposed new ASTM standard, WK9584, Guide for Assessing Potential Hazards of Synthesis Reactions Using Reaction Calorimetry, will help to standardize how the results from reaction calorimetry experiments are used in a process hazard…