A proposed ASTM standard will meet the need for a method that labs can follow when testing samples for mold. The proposed standard (WK17177, Test Method for Examination of Fungal Structures on Tape Lift Samples by Optical Microscopy) will provide labs with an approach based on quality and science. The primary users of the standard will be labs that provide services in the fields of occupational…, Committee D22 on Air Quality Next Meeting:, April 26-May 1, 2015, April committee week, Anaheim, Calif., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Terri L. Williams, Wisconsin Occupational Health Laboratory, University of Wisconsin, Madison, Wis., tel +1.608.224.6261; terri.williams@slh.wisc.edu, ASTM Staff Contact:, Jeffrey Adkins, tel +1.610.832.9738; jadkins@astm.org Release # 9797 March 17, 2015 ###
-
A new ASTM standard consolidates six current standards on structural fasteners. With hundreds of millions of fasteners produced to ASTM specifications each year, industry will benefit from the streamlined approach provided by the new ASTM standard ( F3125 : Specification for High Strength Structural Bolts, Steel and Alloy Steel, Heat Treated, 120 ksi (830 MPa) and150 ksi (1040 MPa) Minimum…, ASTM Committee F16 Next Meeting:, May 17-19, 2015, May committee week, Anaheim, Calif., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Chad Larson, LeJeune Bolt Co., Burnsville, Minn., tel +1.952.890.7700; clarson@lejeunebolt.com, ASTM Staff Contact:, Jennifer Rodgers, tel +1.610.832.9694; jrodgers@astm.org Release #9785 ###
-
In order to keep sound that travels beyond the walls of a particular area, such as medical examination rooms and human resources offices from being overheard by unintended listeners, an ASTM subcommittee specializing in speech privacy is at work on a proposed new standard, WK47433, Performance Specification of Electronic Sound Masking When Used in Building Spaces. “Electronic sound masking…, ASTM Committee E33 Next Meeting:, April 27-28, 2015, April committee week, Anaheim, Calif., Technical Contact:, Kenneth P. Roy, Armstrong World Industries, Lancaster, Pa., tel +1.717.396.5700; kproy@armstrong.com, ASTM Staff Contact:, Kelly Paul, tel +1.610.832.9745; kpaul@astm.org, ASTM PR Contact:, Barbara Schindler, tel +1.610.832.9603; bschindl@astm.org Release #9752
-
Taking a tape-lift sample is one of the main practices used by indoor environmental quality investigators for detecting whether mold structures (for example, spores and hyphae) have either settled onto or colonized the surface. Despite the popularity of the method, there can be significant inconsistency in how tape lifts are collected. A new ASTM standard, ASTM D7910 , Practice for the Collection…, ASTM Committee D22 Next Meeting:, Oct. 5-8, 2014, October Committee Week, New Orleans, La., Technical Contact:, John M. Neville, Ph.D., Bureau Veritas North America Inc., Novi, Mich., Phone: 248-344-3042; john.neville@us.bureauveritas.com, ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9655
-
A new standard, ASTM D7886 , Practice for Asbestos Exposure Assessments for Repetitive Maintenance and Installation Tasks, will aid those testing asbestos exposures by quantifying such exposure levels. Regulations set forth by the U.S. Occupational Safety and Health Administration require that worker exposure to asbestos be determined with a “high level of certainty.” “ASTM D7886 overcomes the…, ASTM Committee D22 Next Meeting:, Oct. 5-8, 2014, October Committee Week, New Orleans, La., Technical Contact:, Andrew F. Oberta, MPS, CIH, The Environmental Consultancy, Austin, Texas, Phone: 512-266-1368; andyobe@aol.com , ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9639
-
Gaseous hydrogen fluoride is a harsh respiratory irritant; the inhalation of hydrofluoric acid mists causes severe lung damage in exposed workers. A proposed new ASTM standard, WK38734 , Test Method for the Determination of Particulate Fluorides and Hydrofluoric Acid Using Filter Sampling and Suppressed Ion Chromatography, will be used to prevent overexposure of hydrofluoric acid/hydrogen…, ASTM Committee D22 Next Meeting:, Oct. 5-8, 2014, October Committee Week, New Orleans, La., Technical Contact:, Dietmar Breuer, IFA, Sankt Augustin, Germany, Phone: +49 (0) 2241 231-2533; dietmar.breuer@dguv.de , ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9585
-
While monitoring air quality is important in many situations, a variety of different quantitative passive samplers are available for such work. A proposed new ASTM standard, ASTM WK45755 , Guide for Selection of Quantitative Passive Samplers for Volatile Organic Compounds in Air, will help users decide which air sampler type will best suit their needs. ASTM WK45755 will cover issues such as the…, ASTM Committee D22 Next Meeting:, Oct. 5-8, 2014, October Committee Week, New Orleans, La., Technical Contact:, Nicola Watson, Markes International, Loveland, Ohio, Phone: 513-488-6161; nwatson@markes.com , ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9578
-
A new ASTM International standard is focused exclusively on testing soil for asbestos. ASTM D7521 , Test Method for Determination of Asbestos in Soil, was developed by Subcommittee D22.07 on Sampling and Analysis of Asbestos , part of ASTM International Committee D22 on Air Quality . According to Alan Segrave, division manager, laboratory services, Bureau Veritas, and an ASTM D22 member, many…, ASTM Committee D22 Next Meeting:, April 14-17, April Committee Week, Indianapolis, Ind., Technical Contact:, Alan M. Segrave, Bureau Veritas North America Inc., Kennesaw, Ga., Phone: 770-590-6706; alan.segrave@us.bureauveritas.com, ASTM Staff Contact:, David Bradley, Phone: 610-832-9681; dbradley@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9295
-
A proposed new ASTM International standard will be helpful to the construction industry in designing acoustic properties for buildings. ASTM WK37294 , Test Method for the Laboratory Measurement of Mechanical Impedance of Building Elements and Prediction of the Sound Transmission Loss Performance, is currently being developed by Subcommittee E33.03 on Sound Transmission , part of ASTM…, ASTM Committee E33 Next Meeting:, April 15-16, 2013, April Committee Week, Indianapolis, Ind., Technical Contact:, Peter Jackson, Ward Process, Holliston, Mass., Phone: 774-233-7011; p.jackson@aapusa.com, ASTM Staff Contact:, Steve Mawn, Phone: 610-832-9726; smawn@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9316
-
A newly approved standard, ASTM D7338 , Guide for the Assessment of Fungal Growth in Buildings, has been developed to provide a go-to reference for anyone testing for mold in buildings. The new standard was developed by Subcommittee D22.08 on Sampling and Analysis of Mold, part of ASTM International Committee D22 on Air Quality. “The lack of consensus standards in the fungal sampling and analysis…, ASTM Committee D22 Next Meeting:, April 10-13, April Committee Week, Anaheim, Calif., Technical Contact:, Lisa Rogers, Mycometer, Inc., Tampa, Fla., Phone: 813-831-6511; lrogers@mycometer.com, ASTM Staff Contact:, David Bradley, Phone: 610-832-9681; dbradley@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8788