Search
Advanced search
Filter by category
Filter by committee
Search results
-
Gaseous hydrogen fluoride is a harsh respiratory irritant; the inhalation of hydrofluoric acid mists causes severe lung damage in exposed workers. A proposed new ASTM standard, WK38734 , Test Method for the Determination of Particulate Fluorides and Hydrofluoric Acid Using Filter Sampling and Suppressed Ion Chromatography, will be used to prevent overexposure of hydrofluoric acid/hydrogen…, ASTM Committee D22 Next Meeting:, Oct. 5-8, 2014, October Committee Week, New Orleans, La., Technical Contact:, Dietmar Breuer, IFA, Sankt Augustin, Germany, Phone: +49 (0) 2241 231-2533; dietmar.breuer@dguv.de , ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9585
-
While monitoring air quality is important in many situations, a variety of different quantitative passive samplers are available for such work. A proposed new ASTM standard, ASTM WK45755 , Guide for Selection of Quantitative Passive Samplers for Volatile Organic Compounds in Air, will help users decide which air sampler type will best suit their needs. ASTM WK45755 will cover issues such as the…, ASTM Committee D22 Next Meeting:, Oct. 5-8, 2014, October Committee Week, New Orleans, La., Technical Contact:, Nicola Watson, Markes International, Loveland, Ohio, Phone: 513-488-6161; nwatson@markes.com , ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9578
-
The use of infrared technology is gaining popularity in the forensic engineering and building science fields. One such use is identifying specific locations of water damage to buildings without requiring complete removal or deconstruction of building systems or facades. A proposed new ASTM International standard will provide guidelines for this usage. ASTM WK44618 , Guide for the Use of Infrared…, Technical Contact:, Robin Girard, Bracken Engineering, Tampa, Fla., Phone: 813-243-4251; rgirard@brackenengineering.com , ASTM Staff Contact:, Kelly Paul, Phone: 610-832-9745; kpaul@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9595
-
Incidents involving electrical systems can result in injuries and fatalities that need to be safely and efficiently investigated and a proposed new ASTM guide will provide a basis for such investigations. ASTM WK41392 , Guide for Investigating Electrical Incidents, is being developed by Subcommittee E58.04 on Electrical Incidents , part of ASTM International Committee E58 on Forensic Engineering…, ASTM Committee E58 Next Meeting:, January 2014, in conjunction with National Academy of Forensic Engineers January meeting, Charlotte, S.C. (date to be determined), Technical Contact:, Johannes Laun, Professional Analysis and Consulting Inc., Sugar Grove, Ill., Phone: 630-466-4040; jclaun@proaacl.com, ASTM Staff Contact:, Kelly Paul, Phone: 610-832-9745; kpaul@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9433
-
A new ASTM International standard is focused exclusively on testing soil for asbestos. ASTM D7521 , Test Method for Determination of Asbestos in Soil, was developed by Subcommittee D22.07 on Sampling and Analysis of Asbestos , part of ASTM International Committee D22 on Air Quality . According to Alan Segrave, division manager, laboratory services, Bureau Veritas, and an ASTM D22 member, many…, ASTM Committee D22 Next Meeting:, April 14-17, April Committee Week, Indianapolis, Ind., Technical Contact:, Alan M. Segrave, Bureau Veritas North America Inc., Kennesaw, Ga., Phone: 770-590-6706; alan.segrave@us.bureauveritas.com, ASTM Staff Contact:, David Bradley, Phone: 610-832-9681; dbradley@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9295
-
All interested parties are invited to join in the standards developing activities of new Subcommittee E58.06 on Incidents Involving Structures , part of ASTM International Committee E58 on Forensic Engineering . Forensic engineering is defined by the National Academy of Forensic Engineers as “the application of the art and science of engineering in matters which are in, or may possibly relate to…, ASTM Committee E58 Next Meeting:, Jan. 18, 2013, in conjunction with the National Society of Forensic Engineers, Newport Beach, Calif., Technical Contact:, Robin Girard, Bracken Engineering, Tampa, Fla., Phone: 813-243-4251; rgirard@brackenengineering.com, ASTM Staff Contact:, Kelly Paul, Phone: 610-832-9745; kpaul@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindler@astm.org R elease #9244
-
Personal protective equipment manufacturers, material manufacturers and end users with an interest in impact resistance are encouraged to contribute to the development of a proposed new standard on measuring transmitted impact force on protective clothing. The proposed standard, ASTM WK38096 , Test Method for Measuring Transmitted Impact Force Through Materials Used in Protective Clothing, is…, ASTM Committee F23 Next Meeting:, Jan 29-31, 2013, January Committee Week, Jacksonville, Fla., Technical Contact:, Angela Fisher, Wells Lamont Industrial, Palatine, Ill., Phone: 612-940-1316; afisher@wellslamont.com, ASTM Contact:, Ashley Wiand, Phone: 610-832-9551; awiand@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9268
-
New Standard for Chemical Permeation Testing Approved by ASTM Personal Protective Clothing CommitteeChemical protective clothing has been widely used to protect skin from health hazards that can be found in the workplace or during a terrorist attack. A new ASTM International standard provides directions in using a computer program, called a permeation calculator, to analyze data following a permeation test, in order to determine when chemicals have gotten inside the clothing. The new standard,…
-
Due to risk of infection from blood-borne pathogens such as human immunodeficiency virus and hepatitis C, hypodermic needle sticks pose a life-safety risk to healthcare professionals, law enforcement officials, sanitation workers and others. A new ASTM International standard addresses the unique mechanics of hypodermic needle puncture as related to protective clothing. ASTM F2878 , Test Method…
-
A newly approved standard, ASTM D7338 , Guide for the Assessment of Fungal Growth in Buildings, has been developed to provide a go-to reference for anyone testing for mold in buildings. The new standard was developed by Subcommittee D22.08 on Sampling and Analysis of Mold, part of ASTM International Committee D22 on Air Quality. “The lack of consensus standards in the fungal sampling and analysis…, ASTM Committee D22 Next Meeting:, April 10-13, April Committee Week, Anaheim, Calif., Technical Contact:, Lisa Rogers, Mycometer, Inc., Tampa, Fla., Phone: 813-831-6511; lrogers@mycometer.com, ASTM Staff Contact:, David Bradley, Phone: 610-832-9681; dbradley@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8788