Purified terephthalic acid, commonly known as PTA, is a major raw material for polymer and plastic manufacture used in making polyester fiber, resin and film. Four new ASTM International standards will be used to determine the presence of the impurities 4-Caraboxybenzaldehyde and p-Toluic Acid in PTA. The four new standards were developed by Subcommittee D16.02 on Oxygenated Aromatics , part of…, ASTM Committee D16 Next Meeting:, Jan. 29-30, 2014, January Committee Week, Houston, Texas, Technical Contact:, Yuhong Zhang, China Petrochemical Corp., Shanghai, China, Phone: 86-21-6846-2281; zhang-yh10@163.com, ASTM Staff Contact:, Kristy Straiton, Phone: 610-832-9640; kstraiton@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9526
-
ASTM International Committee F11 on Vacuum Cleaners has formed a new task group to develop proposed standards for high efficiency particulate air filtration, typically known as HEPA. The task group, part of Subcommittee F11.23 on Filtration, will develop standards to clarify methodology and criteria used to define HEPA filtration for sealed vacuum cleaner systems and filter components used in…, ASTM Committee F11 Next Meeting:, May 20-22, 2013, May Committee Week, Indianapolis, Ind., Technical Contact:, Zoe Wilson, Bissell Homecare Inc., Grand Rapids, Mich., Phone: 616-735-5142; zoe.wilson@bissell.com , ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9338
-
The increase in the number of floor care products in the marketplace that employ wet extraction cleaning systems is the leading factor in the development of a standard that describes a laboratory test for the cleaning effectiveness of such systems. ASTM F2828 , Test Method for Assessing Carpet Cleaning Effectiveness in Terms of Visual Appearance Change When Cleaned with a Wet Extraction Cleaning…, ASTM Committee F11 Next Meeting:, Nov. 12-14, November Committee Week, Atlanta, Ga., Technical Contact:, Kenneth M. Lee, Bissell Homecare Inc., Grand Rapids, Mich., Phone: 616-791-0608; ken.lee@bissell.com, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9290
-
Purified terephthalic acid, often known simply as PTA, is in high demand as the key raw material for the manufacture of polyester fiber, resin and film. Two proposed ASTM standards are currently being developed that will be used to find major impurities in PTA product. The two proposed standards are ASTM WK36121 , Test Method for Determination of p-Toluic Acid and 4-Carboxybenzaldehyde in…, ASTM Committee D16 Next Meeting:, Jan. 30-31, 2013, January Committee Week, Jacksonville, Fla., Technical Contact:, Yuhong Zhang, China Petrochemical Corp., Shanghai, China, Phone: 011-86-21-68462281; zhangyh.sshy@sinopec.com, ASTM Staff Contact:, Christine DeJong, Phone: 610-832-9736; cdejong@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9266
-
A new ASTM International standard will provide safety and risk management professionals with an aid in measuring the slip resistance of footwear in a wide variety of flooring situations. ASTM F2913 , Test Method for Measuring the Coefficient of Friction for Evaluation of Slip Performance of Footwear and Test Surfaces/Flooring Using a Whole Shoe Tester, is under the jurisdiction of Subcommittee…
-
All interested parties are invited to join a new ASTM task group that will be developing standards to measure the performance of battery operated vacuum cleaners. The task group is under the jurisdiction of ASTM International Committee F11 on Vacuum Cleaners . Task Group F11.50.13 on the Development of ASTM Standard Test Methods for the Measurement of Battery-Powered Vacuum Cleaner Performance is…
-
Tribometers are used to assess the potential of humans to slip while walking on various surfaces. A new ASTM International test method will be used to provide a reference standard against which to validate and calibrate the performance of tribometers. ASTM F2508 , Practice for Validation and Calibration of Walkway Tribometers Using Reference Surfaces, has been developed by Subcommittee F13.10 on…
-
Hard surface cleaning products that employ steam comprise a new and growing segment of the vacuum cleaner market, although there are currently no agreed-upon industry-wide standards for such products. A new ASTM subcommittee, F11.40 on Steam Products , part of ASTM International Committee F11 on Vacuum Cleaners , will be developing test methods to measure the performance and durability of steam…
-
ASTM International Committee F13 on Pedestrian/Walkway Safety and Footwear is currently working on a proposed new standard for footwear designed for workers who do not necessarily need safety toe shoes but could use other protection such as puncture resistance, electrical shock protection and electrical grounding. The proposed new standard, ASTM WK27855 , Specification for Performance…
-
Manufacturers of toluene, mixed xylenes and p-xylene are often required to determine the type and amount of impurities that remain from manufacture. A new ASTM International standard, D7504 , Test Method for Trace Impurities in Monocyclic Aromatic Hydrocarbons by Gas Chromatography and Effective Carbon Number, can now be used as an internal quality control tool where these products are produced…