Search
Advanced search
Filter by category
Filter by committee
Search results
-
A recently published ASTM International standard covers a new type of resilient flooring tile product based on a polyester binder. ASTM F2982 , Specification for Polyester Composition Floor Tile, was developed by Subcommittee F06.80 on Specifications , part of ASTM International Committee F06 on Resilient Floor Coverings . “ ASTM F2982 sets forth an explicit set of compositional and performance…, ASTM Committee F06 Next Meeting:, May 22-23, 2013, May Committee Week, Indianapolis, Ind., Technical Contact:, Thomas Erisman, Armstrong World Industries, Lancaster, Pa., Phone: 717-396-5354; tcerisman@armstrong.com, ASTM Staff Contact:, Stephen Mawn, Phone: 610-832-9726; smawn@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9271
-
Purified terephthalic acid, often known simply as PTA, is in high demand as the key raw material for the manufacture of polyester fiber, resin and film. Two proposed ASTM standards are currently being developed that will be used to find major impurities in PTA product. The two proposed standards are ASTM WK36121 , Test Method for Determination of p-Toluic Acid and 4-Carboxybenzaldehyde in…, ASTM Committee D16 Next Meeting:, Jan. 30-31, 2013, January Committee Week, Jacksonville, Fla., Technical Contact:, Yuhong Zhang, China Petrochemical Corp., Shanghai, China, Phone: 011-86-21-68462281; zhangyh.sshy@sinopec.com, ASTM Staff Contact:, Christine DeJong, Phone: 610-832-9736; cdejong@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9266
-
Non-destructive moisture meters are now widely used in determining moisture levels in concrete, gypsum concrete and other types of floor slabs. A new ASTM International standard qualifies the types of meter suitable for this purpose and provides guidelines for how, where and when such moisture meters are used and what limitations exist. The new standard, ASTM F2659 , Guide for Preliminary…, ASTM Committee F06 Next Meeting:, Nov. 10-11, New Orleans, La., Technical Contact:, Sean Fallon, Dublin, Ireland, Phone: +011-353-1-285-1861; seanfallon@ireland.com, ASTM Staff Contact:, Stephen Mawn, Phone: 610-832-9726; smawn@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #870/Oct2010
-
A proposed new standard being developed by ASTM International Committee F30 on Emergency Medical Services will be useful to medical equipment manufacturers, certification agencies and care providers, with patients being the ultimate beneficiaries. The proposed new standard, ASTM WK27973 , Specification for Environmental Performance of Medical Equipment for Use on Fixed and Rotary-Wing Aircraft,…, Technical Contact:, Pete Chambers, Marketing Assessment Inc., Phone: 703-673-9003; pete@marketingassessment.com, ASTM Staff Contact:, Scott Orthey, Phone: 610-832-9730; sorthey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8671/Sept2010
-
ASTM International Committee F08 on Sports Equipment and Facilities is focusing on elliptical equipment in its two latest approved standards. Both F2810, Specification for Elliptical Trainers, and ASTM F2811 , Test Methods for Evaluating Design and Performance Characteristics of Elliptical Trainers, are under the jurisdiction of Subcommittee F08.30 on Fitness Products. Harvey Voris, vice…, ASTM Committee F08 Next Meeting:, Nov. 16-19, November Committee Week, San Antonio, Texas, Technical Contact:, Harvey Voris, Paramount Fitness Corp., Los Angeles, Calif., Phone: 323-721-2121; hvoris@paramountfitness.com, ASTM Staff Contact:, Christine Basile, Phone: 610-832-9728; cbasile@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8672/Sept2010
-
Special considerations need to be made for flooring in multi-purpose rooms, particularly those in child care buildings, elementary schools and long-term care facilities. ASTM International Committee F06 on Resilient Floor Coverings is currently developing a proposed new standard for such flooring. WK24836 , Specification for Active Area, Multipurpose Flooring, is under the jurisdiction of…
-
Manufacturers of toluene, mixed xylenes and p-xylene are often required to determine the type and amount of impurities that remain from manufacture. A new ASTM International standard, D7504 , Test Method for Trace Impurities in Monocyclic Aromatic Hydrocarbons by Gas Chromatography and Effective Carbon Number, can now be used as an internal quality control tool where these products are produced…
-
Mass casualty events, including both natural disasters and man-made events, subject caregivers, patients and medical equipment to environmental extremes. A new standard being developed by ASTM International Committee F30 on Emergency Medical Services provides guidance for how medical equipment is expected to perform under the severe conditions of a mass casualty event. The proposed standard, ASTM…
-
Chemical plants and contract and research laboratories will all be likely users of a new ASTM International standard, D 7183 , Test Method for Determination of Total Sulfur in Aromatic Hydrocarbons and Related Chemicals by Ultraviolet Fluorescence. D 7183 was developed by Subcommittee D16.04 on Instrumental Analysis, part of ASTM International Committee D16 on Aromatic Hydrocarbons and Related…
-
ASTM International standard D 1555, Test Method for Calculation of Volume and Weight of Industrial Aromatic Hydrocarbons and Cyclohexane, and its metric equivalent, D 1555M, have been revised by Committee D16 on Aromatic Hydrocarbons and Related Chemicals. The revision affects the basis for correcting volume from any temperature to 60 F (or 15 C using D 1555M), as well as calculating the weight…