Search
Advanced search
Filter by category
Filter by committee
Search results
-
ASTM International Committee E56 on Nanotechnology has created a new subcommittee, E56.06 on Nano-Enabled Consumer Products. The scope of E56.06 is to develop scientifically credible standards for identification, evaluation and assessment of engineered nanomaterials in consumer products. Members of E56.06 will develop standards for determining the presence of engineered nanomaterials in consumer…, ASTM Committee E56 Next Meeting:, Nov 15-16, November Committee Week, San Antonio, Texas, Technical Contact:, (Chairman, E56) Debbie Kaiser, National Institute of Standards and Technology, Gaithersburg, Md., Phone: 301-975-6759; debra.kaiser@nist.gov ; (Subcommittee E56.06) Aleks Stefaniak, National Institute for Occupational Safety and Health, Morgantown, W.Va., Phone: 304-285-6302; boq9@cdc.gov, ASTM Staff Contact:, Timothy Brooke, Phone: 610-832-9729; tbrooke@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8698/Sept2010
-
Creep-fatigue testing simulates the loading and temperature conditions experienced by turbine components of aircraft engines, nuclear reactor components and fossil power plant components during service. With increasing need for cyclic operation during peak power demands, reliable creep-fatigue test data is necessary for the life assessment of aging power plants. A new ASTM standard, ASTM E2714 ,…
-
A proposed new ASTM standard will assist in establishing tests for fretting fatigue, an issue at attachments and joints in a variety of mechanical, aeronautical and biomedical engineering systems and devices. WK24298 , Guide for Fretting Fatigue Testing, is being developed by Subcommittee E08.05 on Cyclic Deformation and Fatigue Crack Formation, part of ASTM International Committee E08 on Fatigue…, ASTM Committee E08 Next Meeting:, May 17-20, 2010, May Committee Week, St. Louis, Mo., Technical Contact:, Richard W. Neu, Georgia Institute of Technology, Atlanta, Ga., Phone: 404-894-3074; rick.neu@gatech.edu, ASTM Staff Contact:, Jeff Adkins, Phone: 610-832-9738; jadkins@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8430/Dec2009
-
A revision to an important ASTM nanotechnology standard incorporates a large-scale interlaboratory study that took place in 2008. The revised standard, ASTM E2490 , Guide for Measurement of Particle Size Distribution of Nanomaterials in Suspension by Photon Correlation Spectroscopy (PCS), is under the jurisdiction of Subcommittee E56.02 on Characterization: Physical, Chemical and Toxicological…
-
Data produced from the use of a proposed new ASTM International standard will be employed in the design of new, more efficient aircraft engines as well as for piping, steam and gas turbines used in power generation. The proposed new standard, WK21984 , Test Method for Creep-Fatigue Crack Growth Rate Testing, is being developed by Subcommittee E08.06 on Crack Growth Behavior, part of ASTM…
-
A workshop on the role of standards in the emerging field of nanotechnology will be held Oct. 8-9, 2008, at the National Institute of Standards and Technology near Washington, D.C. The workshop, "Enabling Standards for Nanomaterial Characterization," is being co-sponsored by the National Cancer Institute's Nanotechnology Characterization Laboratory, the National Institute of Standards and…
-
The battle against cancer is being fought on many fronts. Among the most cutting-edge research efforts are attempts to engineer nanotechnology-based therapies. To aid in this endeavor, the Nanotechnology Characterization Laboratory, part of the National Cancer Institute’s Alliance for Nanotechnology in Cancer and the National Cancer Institute at Frederick, has developed methods for nanoparticle…, E2524, , Test Method for Analysis of Hemolytic Properties of Nanoparticles, -E2524 is a protocol for examining the destruction of red blood cells (hemolysis) that can lead to anemia, jaundice and other issues. All intravenously administered drugs must be examined to determine potential for hemolysis. • , E2525, , Test Method for Evaluation of the Effect of Nanoparticulate Materials on the Formation of Mouse Granulocyte-Macrophage Colonies, -E2525 describes a method for evaluating nanoparticle stimulation or inhibition of the maturation of certain bone marrow cells (macrophages). A common side effect of anti-cancer drugs is inhibition of this process, and bone marrow cells may be particularly sensitive to nano-scale material. • , E2526, , Test Method for Evaluation of Cytotoxicity of Nanoparticulate Materials on Porcine Kidney Cells and Human Hepatocarcinoma Cells, -Because studies have indicated that many nanoparticles are cleared from the body through the kidney or liver, these organs are good choices for target organ toxicity evaluation. E2526 presents a method for evaluation of nanomaterial toxicity by examining effects on kidney and cancerous liver cells. Martin Fritts is senior principal scientist at the Nanotechnology Characterization Laboratory and…
-
ASTM International Committee E56 on Nanotechnology has approved its first standard, E 2456 , Terminology for Nanotechnology. The new standard is under the jurisdiction of Subcommittee E56.01 on Terminology and Nomenclature. Because of the great need for a terminology document that is globally recognized and because of the cooperation of several organizations in making the document a reality,…
-
Verifying the results of application software used to calculate the mechanical properties of materials is the subject of a new standard developed by ASTM International Committee E08 on Fatigue and Fracture. The new standard, E 2443, Guide for Verifying Computer-Generated Test Results Through the Use of Standard Data Sets, is under the jurisdiction of Subcommittee E08.03 on Advanced Apparatus and…
-
Many structures, such as aircraft or other lightweight vehicles, are made from thin-ductile structural materials that exhibit low crack-front constraint, which allows for extensive plastic yielding of the material around a crack front. However, many current standards, such as E 399, Test Method for Linear-Elastic Plane-Strain Fracture Toughness K Ic of Metallic Materials, or E 1820, Test Method…