Accidents involving the handling of annealed glass have heightened interest in standards that could improve safety in the glass industry. In response, ASTM International Committee E34 on Occupational Health and Safety has approved a new standard, ASTM E2875/E2875M , Guide for Personal Protective Equipment for the Handling of Flat Glass. The new standard was developed by Subcommittee E34.35 on…, ASTM Committee E34 Next Meeting:, Oct. 24-25, 2012, October committee week, Atlanta, Ga., Technical Contact:, Michael Marsala, Guardian Industries Corp., Auburn Hills, Mich., Phone: 248-340-2322; mmarsala@guardian.com, ASTM Staff Contact:, Kevin Shanahan, Phone: 610-832-9737; kshanahan@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9257
-
Current members of ASTM International Committees C01 on Cement and C09 on Concrete and Concrete Aggregates , and other interested parties, are invited to join a new C01 subcommittee, C01.98 on Sustainability Assessment. The scope of C01.98 is to support the development and maintenance of standards related to methodologies and metrics for assessing sustainability in the manufacture and use of…
-
A proposed new ASTM International standard will improve the accuracy and usefulness of radiometry-related uncertainty estimates in a wide range of fast developing solar renewable energy applications, such as system performance and acceptance testing, resource assessment and solar energy system design engineering. The proposed standard, ASTM WK36479 , Practice for Uncertainty Evaluation of…
-
A new ASTM International practice provides a standard for preparing a mixture of cement paste that will simulate the shearing experienced by the cement paste in concrete. The new standard, ASTM C1738 , Practice for High-Shear Mixing of Hydraulic Cement Pastes, was developed by Subcommittee C01.22 on Workability , part of ASTM International Committee C01 on Cement . According to Chiara Ferraris,…
-
Manufacturers of solar radiometers and testing laboratories for solar energy, materials and durability testing will be among the primary users of a new ASTM International standard that outlines procedures using indoor test methods to calibrate radiometers with dissimilar detectors. The new standard, ASTM G207 , Test Method for Indoor Transfer of Calibration from Reference to Field Pyranometers,…, ASTM Committee G03 Next Meeting:, Jan. 29-31, 2012, January Committee Week, Atlanta, Ga., Technical Contact:, Daryl Myers, National Renewable Energy Laboratory, Golden, Colo., Phone: 303-384-6768; daryl.myers@nrel.gov, ASTM Staff Contact:, Jeff Adkins, Phone: 610-832-9738; jadkins@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8965
-
A new ASTM International standard provides a more detailed and complete description of a test protocol that has been used for more than 40 years in code requirements and specifications for fire-retardant-treated wood. This test is now also used in some codes for building products that are not wood. The new standard, ASTM E2768 , Test Method for Extended Duration Surface Burning Characteristics of…
-
Consumers who are purchasing building materials for homes want to be assured that the materials are mold resistant. A proposed new ASTM standard will allow for a mold-resistance rating to be given to specific materials, depending on how the materials perform to the test method. The proposed new standard, ASTM WK32079 , Test Method for Determination of Mold Growth on Building Products Designed for…
-
A new ASTM International subcommittee has been created to develop standards that will be meaningful and accurate performance indicators to measure work-related injury and illness performance throughout the world. Subcommittee E34.55 on Occupational Safety and Health Performance Improvement is under the jurisdiction of ASTM International Committee E34 on Occupational Health and Safety. “Measuring…
-
While standards for outdoor calibration techniques for solar radiometers exist, there are currently no general standards that deal with issues of indoor calibration transfers between radiometers of different design. A proposed new ASTM standard, ASTM WK27263, Test Method for Indoor Transfer of Calibration from Reference to Field Pyranometers, will address in detail issues associated with…
-
ASTM International Subcommittee E34.50 on Health and Safety Standards for Metalworking Fluids has developed three new standards. Two of the recently approved ASTM standards cover aspects of water-miscible metalworking fluids, while the third concerns prevention of dermatitis in the wet metal removal fluid environment., Prevention of Dermatitis, Dermatitis is an inflammatory response of the skin to a chemical or physical agent. While redness, swelling and itching are typical signs of dermatitis, symptoms can be more severe as well. A new ASTM standard, ASTM E2693 , Practice for Prevention of Dermatitis in the Wet Metal Removal Fluid Environment, discusses dermatitis and its causes and presents a comprehensive approach to dermatitis…, Metalworking Fluids, Two new E34.50 standards address the detection of microbial contamination in metalworking fluids: ASTM E2657 , Test Method for Determination of Endotoxin Concentrations in Water-Miscible Metalworking Fluids, and ASTM E2694 , Test Method for Measurement of Adenosine Triphosphate in Water-Miscible Metalworking Fluids. Both ASTM E2657 and ASTM E2694 measure biological contamination in metalworking…, Participation Invited, The subcommittee is currently looking for participants for an interlaboratory study for ASTM E2657 and ASTM E2694 . “We plan to use a single set of MWF for both standards, so labs who are interested in either or both are welcome to participate,” says Passman. “A few labs will run both the ILS’s for both standards, while most will run one or the other.” Subcommittee E34.50 is part of ASTM…