As a result of the Safety Equipment Institute becoming a subsidiary of ASTM International on April 19, SEI is expanding its offerings beyond its existing product certifications to include personnel certifications and environmental declaration programs. The SEI Board Standing Committee on Certification Programs met for the first time yesterday. It approved operating manuals and procedures for SEI’…, Media Inquiries:, Dan Bergels, tel. +1.610.832.9602; dbergels@astm.org, SEI Staff Contact:, Pat Gleason, tel. +1.703.442.5732; pgleason@seinet.org Release #10101
-
ASTM International’s Fire Committee ( E05 ) is developing a standard that will test fire resistance of wooden utility poles. Utility companies and coating and treatment manufacturers will use the standard to test new products that could protect the poles. “Utility poles are frequently exposed to high intensity wildfires throughout the world,” says ASTM member Brent M. Pickett, Ph.D. “If these…, ASTM Committee E05 on Fire Next Meeting:, June 27-30, 2016, June Committee Week, Chicago, Ill., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Brent M. Pickett, Ph.D., Western Fire Center Inc., Kelso, Wash., tel +1.360.423.1400; brent@westernfire.com , ASTM Staff Contact:, Thomas O’Toole, tel +1.610.832.9739; totoole@astm.org Release #9989
-
A new ASTM test method will test the strength and durability of wood-to-wood adhesives when put under pressures of weight, temperature and humidity. This “creep resistance” standard will soon be available for purchase as ASTM D7966, Test Method for Resistance to Creep of Adhesives in Static Shear by Compression Loading (Wood-to-Wood). Wood-to-wood adhesives are an increasingly essential part of…, ASTM Committee D14 Next Meeting:, April 26-28, 2015, April Committee Week, Anaheim, Calif., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Mark Clark, Momentive Specialty Chemicals Inc., Springfield, Ore., tel +1.541.741.6674; mark.clark@momentive.com, ASTM Staff Contact:, Joseph Hugo, tel +1.610.832.9740; jhugo@astm.org Release #9799 ###
-
Knowing that the floor beneath you is safe is something most of us take for granted. A proposed new ASTM International standard will help people who have to think about, and test for, floor safety all the time. The proposed new standard is ASTM WK47030 , Practice for Evaluating Concrete Floor Systems to Receive Resilient Flooring. The World Floor Covering Association and the Floor Covering…, ASTM Committee F06 Next Meeting:, Nov. 12-13, November Committee Week, New Orleans, La., Technical Contact:, George Donnelly, George Donnelly Testing and Inspections, Hot Springs, Ark., tel +1.501.915.0626; info@moisturetesting.com, ASTM Staff Contact:, Stephen Mawn, tel +1.610.832.9726; smawn@astm.org, ASTM PR Contact:, Barbara Schindler, tel +1.610.832.9603; bschindl@astm.org Release #9706
-
Adopted in 2005, Chapter 7A of the California Building Code describes provisions for attic vents for new construction in wildfire-prone areas. While the California code notes that attic vents should resist the intrusion of embers and flames, there had not been a standard to evaluate such intrusion. A new standard, ASTM E2886/E2886M , Test Method for Evaluating the Ability of Exterior Vents to…, ASTM Committee E05 Next Meeting:, Dec. 8-11, 2014, December Committee, New Orleans, La., Technical Contact:, Stephen Quarles, Insurance Institute for Business and Home Safety, Richburg, S.C., Phone: 803-789-4209; squarles@ibhs.org , ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9617
-
A proposed new ASTM International standard is being developed for mounting plastic pipe and tube in the Steiner tunnel furnace. The draft procedure will help determine the fire-related properties of the pipe and tube in accordance with ASTM E84, Test Method for Surface Burning Characteristics of Building Materials. ASTM WK44535 , Practice for Mounting of Plastic Pipe, Plastic Tubing, Plastic Pipe…, ASTM Committee E05 Next Meeting:, June 23-26, 2014, June Committee, Toronto, Ontario, Canada, Technical Contact:, Joe Zicherman, Fire Cause Analysis, Berkeley, Calif., Phone: 510-649-1300; zicherman46@gmail.com, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9635
-
A new ASTM International standard will provide a qualitative means to determine the potential effect of plasticizers contained within polyvinylchloride floor covering materials on a specific adhesive. ASTM D7888 , Practice for Evaluating Adhesive and the Effects of Plasticizer Found Within Polyvinylchloride-Backed Floor Coverings, was developed by Subcommittee D14.10 on Working Properties, part…, ASTM Committee D14 Next Meeting:, April 6-8, 2014, April Committee Week, Toronto, Ontario, Canada, Technical Contact:, Larry Press, Helmitin Adhesives Inc., Jacksonville, Fla., Phone: 904-765-2364; l.press@helmit inadehesives.com , ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9533
-
For more than 100 years, cork tile has been commonly used as a floor and wall covering for residential and commercial use. A new ASTM International standard, ASTM F3008 , Specification for Cork Floor Tile, specifies requirements for cork floor coverings made from agglomerated composition cork supplied in tile form, which is designed to be used with a factory finish or an in situ finish, or both.…, ASTM Committee F06 Next Meeting:, May 7-8, 2014, Clearwater, Fla., Technical Contact:, Christopher Capobianco, Spartan Surfaces, Patchogue, N.Y., Phone: 631-275-6494; christopher@spartansurfaces.com, ASTM Staff Contact:, Stephen Mawn, Phone: 610-832-9726; smawn@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9523
-
A wildland-urban interface is a transitional zone between unoccupied land and human development. There are currently more than 40 million homes located within WUI areas throughout the United States. A proposed new ASTM standard will be used to alleviate the issue of fire conditions that exist due to eaves and other projections in structures that exist in WUI areas. ASTM WK37414, Test Method for…, ASTM Committee E05 Next Meeting:, June 23-26, 2014, June Committee Week, Toronto, Ontario, Canada, Technical Contact:, John Simontacchi, Firefree Coatings Inc., San Rafael, Calif., Phone: 415-459-6488; jsimontacchi@firefree.com , ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9529
-
A recently published ASTM International standard covers a new type of resilient flooring tile product based on a polyester binder. ASTM F2982 , Specification for Polyester Composition Floor Tile, was developed by Subcommittee F06.80 on Specifications , part of ASTM International Committee F06 on Resilient Floor Coverings . “ ASTM F2982 sets forth an explicit set of compositional and performance…, ASTM Committee F06 Next Meeting:, May 22-23, 2013, May Committee Week, Indianapolis, Ind., Technical Contact:, Thomas Erisman, Armstrong World Industries, Lancaster, Pa., Phone: 717-396-5354; tcerisman@armstrong.com, ASTM Staff Contact:, Stephen Mawn, Phone: 610-832-9726; smawn@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9271