Search
Advanced search
Filter by category
Filter by committee
Search results
-
A new ASTM International standard will help oil spill responders evaluate the stability of water-in-oil mixtures. Specifically, the new standard (soon to be published as F3045, Test Method for the Evaluation of the Stability of Water-in-Oil Mixtures Formed from Crude Oil and Petroleum Products Mixed with Saline Water) provides a laboratory test method to determine the tendencies of emulsions and…, ASTM Committee F20 on Hazardous Substances and Oil Spill Response Next Meeting, : Oct. 25-26, 2016, October Committee Week, Orlando, Fla., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Mervin Fingas, Edmonton, Alberta, Canada, tel +1.780.989.6059; fingasmerv@shaw.ca , ASTM Staff Contact:, Jeffrey Adkins, tel +1.610.832.9738; jadkins@astm.org Release #9936
-
A proposed ASTM standard could help improve workplace safety by describing proximity alarm systems that can be used to prevent cranes, utility trucks, and other equipment from encroaching inside OSHA minimum approach distances and contacting high-voltage power lines. The standard would be most useful to the construction industry, but it could also help in firefighting, drilling, mining,…, ASTM Committee F18 on Electrical Protective Equipment for Workers Next Meeting:, Oct. 4-7, 2015, Las Vegas, Nev., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Lance Burney, Sigalarm, Sanford, Fla., tel +1.407.321.0722; lance@sigalarminc.com , ASTM Staff Contact:, Kevin Shanahan, tel +1.610.832.9737; kshanahan@astm.org Release #9903
-
A new ASTM test method will test the strength and durability of wood-to-wood adhesives when put under pressures of weight, temperature and humidity. This “creep resistance” standard will soon be available for purchase as ASTM D7966, Test Method for Resistance to Creep of Adhesives in Static Shear by Compression Loading (Wood-to-Wood). Wood-to-wood adhesives are an increasingly essential part of…, ASTM Committee D14 Next Meeting:, April 26-28, 2015, April Committee Week, Anaheim, Calif., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Mark Clark, Momentive Specialty Chemicals Inc., Springfield, Ore., tel +1.541.741.6674; mark.clark@momentive.com, ASTM Staff Contact:, Joseph Hugo, tel +1.610.832.9740; jhugo@astm.org Release #9799 ###
-
A proposed new ASTM standard will provide a lab test to determine how various types of oil will interact with water in oil spill situations. Information gleaned from such testing will ultimately lead to more effective oil spill recovery. All interested parties are welcome to join in the ongoing development of the standard ( WK41247 , Test Method for the Evaluation of the Stability of Water-in-Oil…, ASTM Committee F20 on Hazardous Substances and Oil Spill Response Next Meeting:, Oct. 27-28, 2015, October committee week, Tampa, Fla., Technical Contact:, Mervin Fingas, Edmonton, Alberta, Canada, tel +1.780.989.6059; fingasmerv@shaw.ca, ASTM Staff Contact:, Jeffrey Adkins, tel +1.610.832.9738; jadkins@astm.org, ASTM PR Contact:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org Release #9772
-
A new ASTM International standard will provide a qualitative means to determine the potential effect of plasticizers contained within polyvinylchloride floor covering materials on a specific adhesive. ASTM D7888 , Practice for Evaluating Adhesive and the Effects of Plasticizer Found Within Polyvinylchloride-Backed Floor Coverings, was developed by Subcommittee D14.10 on Working Properties, part…, ASTM Committee D14 Next Meeting:, April 6-8, 2014, April Committee Week, Toronto, Ontario, Canada, Technical Contact:, Larry Press, Helmitin Adhesives Inc., Jacksonville, Fla., Phone: 904-765-2364; l.press@helmit inadehesives.com , ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9533
-
Since 2009, the National Fire Protection Association has required arc rated gloves in its NFPA70E, Standard for Electrical Safety in the Workplace. A new ASTM standard will now provide arc rating thermal protective values for gloves, which will allow more gloves to be used inside an arc flash zone when there is no shock hazard. The new standard, ASTM F2675/F2675M , Test Method for Determining Arc…, ASTM Committee F18 Next Meeting:, Oct. 20-23, 2013, Charleston, S.C., Technical Contact:, Hugh Hoagland, ArcWear, Louisville, Ky., Phone: 502-832-9737; hugh@arcwear.com , ASTM Staff Contact:, Kevin Shanahan, Phone: 610-832-9737, kshanahan@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9469
-
Coated fabric products used for oil spill response procedures can deteriorate when stored for long periods of time. A proposed new ASTM standard will provide a nondestructive test for stored equipment to be evaluated for continued suitability over time. ASTM WK37298 , Test Method for Determining Storage Life of Coated Fabric Products, is being developed by Subcommittee F20.11 on Control , part of…, ASTM Committee F20 Next Meeting:, Oct. 23-24, 2012, October Committee Week, Atlanta, Ga., Technical Contact:, Peter Lane, Applied Fabric Technologies Inc., Applied Fabric Technologies Inc., Morris Skimmers International LLC, Orchard Park, N.Y., Phone: 716-662-0632; lane@afti.com, ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9310
-
ASTM International Committee F20 on Hazardous Substances and Oil Spill Response has approved several standards for in-situ burning. The latest proposed standard on this subject, ASTM WK37324 , Guide for Evaluation of In-Situ Burning Effectiveness, is currently being developed by Subcommittee F20.15 on In-Situ Burning . In-situ burning is a controlled burning, at the spill location, of oil that…, ASTM Committee F20 Next Meeting:, Oct. 23-24, 2012, October Committee Week, Atlanta, Ga., Technical Contact:, Steve Potter, SL Ross Environmental Research Ltd., Ottawa, Ontario, Canada, Phone: 613-232-1564; steve@slross.com, ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-932-9738; jadkins@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9294
-
Many manufacturers have their own methods for testing adhesives for carpet or resilient or wood floor coverings. A new ASTM standard addresses this inconsistency by presenting a set of adhesive requirements that can be used throughout the floor covering industry. The new standard, ASTM D7799 , Specification for Tufted and Woven Broadloom Carpet Adhesives Without Homogenous PVC or Non-PVC Backings…
-
A proposed new standard being developed by ASTM International Committee F18 on Electrical Protective Equipment for Workers will provide guidance to assist in the required testing of live-line tools. ASTM WK33590 , Guide for In-Service Inspection, Maintenance and Electrical Testing of Insulating Tools (Fiberglass-Reinforced Plastic (FPR) and Wooden Live-Line Tools), is under the jurisdiction of…