Search
Advanced search
Filter by category
Filter by committee
Search results
-
ASTM F2989 is a new ASTM International standard that covers unalloyed titanium components that are used for surgical implants. The new Specification for Metal Injection Molded Unalloyed Titanium Components for Surgical Implant Applications was developed by Subcommittee F04.12 on Metallurgical Materials , part of ASTM International Committee F04 on Medical and Surgical Materials and Devices . …, ASTM Committee F04 Next Meeting:, May 21-24, 2013, May Committee Week, Indianapolis, Ind., Technical Contact:, Matthias Scharvogel, Element 22 GmbH, Kiel, Germany, Phone: +49-431-659-4620; matthias.scharvogel@element22.de, ASTM Staff Contact:, Pat Picariello, Phone: 610-832-9720; ppicariello@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9336
-
All interested parties are invited to join in the ongoing development of ASTM International standard ASTM D3181 , Guide for Conducting Wear Tests on Textiles. The standard is now under the jurisdiction of Subcommittee D13.60 on Fabric Test Methods, Specific , part of ASTM International Committee D13 on Textiles . ASTM D3181 is used to provide data that will help predict the expected wear…, ASTM Committee D13 Next Meeting:, June 9-12, 2013, June Committee Week, Indianapolis, Ind., Technical Contact:, Norma M. Keyes, Keyes Consulting LLC, Apex, N.C., Phone: 919-362-4044; keyesconsult@att.net, ASTM Staff Contact:, Jennifer Rodgers, Phone: 610-832-9694; jrodgers@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9320
-
There has long been a need within the tissue engineering/regenerative medicine sector for three-dimensional reference scaffolds to serve as physical standards for the materials that are used as beds for the growth of cell cultures. The National Institute of Standards and Technology has created such references, which will eventually be accompanied by a proposed ASTM International standard that…, ASTM Committee F04 Next Meeting:, May 21-24, 2013, May Committee Week, Indianapolis, Ind., Technical Contact:, Carl G. Simon Jr., Ph.D., Biosystems and Biomaterials Division, National Institute of Standards and Technology, Gaithersburg, Md., Phone: 301-975-8574; carl.simon@nist.gov, ASTM Staff Contact:, Pat Picariello, Phone: 610-832-9720; ppicariello@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9298
-
Many types of surgical implants and other medical devices are made of polymeric materials. A new ASTM standard covers the raw material properties for a high strength polymer used for surgical implants. ASTM F2820 , Specification for Polyetherketoneketone (PEKK) Polymers for Surgical Implant Applications, has been developed by ASTM International Subcommittee F04.11 on Polymeric Materials , part of…, ASTM Committee F04 Next Meeting:, May 21-24, 2013, May Committee Week, Indianapolis, Ind., Technical Contact:, Jon P. Moseley, Ph.D., Wright Medical Technology Inc., Arlington, Tenn., Phone: 901-867-4414; jon.moseley@wmt.com, ASTM Staff Contact:, Pat Picariello, Phone: 610-832-9720, ppicariello@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9276
-
A new ASTM International standard provides a much-needed methodology for determining the shelf life of various attributes of endovascular devices. The new standard, ASTM F2914 , Guide for Identification of Shelf-Life Test Attributes for Endovascular Devices, was developed by Subcommittee F04.30 on Cardiovascular Standards , part of ASTM International Committee F04 on Medical and Surgical…, ASTM Committee F04 Next Meeting:, Nov. 13-16, 2012, November Committee Week, Atlanta, Ga., Technical Contact:, Benjamin Gundale, Boston Scientific, Maple Grove, Minn., Phone: 763-494-2771; gundaleb@bsci.com, ASTM Staff Contact:, Pat Picariello, Phone: 610-832-9720; ppicarie@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9264
-
Subcommittee D13.21 on Pile Floor Coverings is seeking experts who may be using ASTM D5251 , Practice for the Operation of the Tetrapod Walker Drum Tester. ASTM D5251 describes the equipment and operation of the Tetrapod Walker for testing unused pile floor coverings with a thickness of 20 mm or less. The subcommittee is hoping to gauge the current level of interest in ASTM D5251. D13.21, which…
-
All interested parties are invited to join in the development of a proposed new ASTM International standard that will identify and define sustainable best management practices that are used in commercial laundry facilities to reduce their impact on the environment. ASTM WK35985 , Practice for Sustainable Laundry Best Management Practices, is being developed by Subcommittee D13.40 on…, ASTM Committee D13 Next Meeting:, June 24-27, 2012, June committee week, San Diego, Calif., Technical Contact:, Gary D. Gramp, Textile Rental Services Association, Alexandria, Va., Phone: 703-519-0029, ext. 111; ggramp@trsa.org, ASTM Staff Contact:, Jennifer Rodgers, Phone: 610-832-9694; jrodgers@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9101
-
New functionalities in a particular group of orthopedic spinal devices will be addressed in a proposed new ASTM standard. ASTM WK34549 , Test Methods for Intervertebral Body Fusion Devices with Integrated Fixation Components, is being developed by Subcommittee F04.25 on Spinal Devices , part of ASTM International Committee F04 on Medical and Surgical Materials and Devices . According to Andrew…
-
One of the most important characteristics of a curved surgical needle is how easily it can pass through tissue. This characteristic, known as penetration force, is important for several reasons, which include minimizing scarring and dealing with highly communicable diseases such as hepatitis. ASTM International Committee F04 on Medical and Surgical Materials and Devices is currently developing a…
-
There are currently several uses of alloy UNS R56320 in surgical applications and implants, but the only ASTM surgical standard for the alloys covers tubing [ ASTM F2146 , Specification for Wrought Titanium-3Aluminum-2.5Vanadium Alloy Seamless Tubing for Surgical Implant Applications (UNS R56320)]. A proposed new ASTM standard will reflect the more widespread use of UNS R56320. ASTM WK34079 ,…