Search
Advanced search
Filter by category
Filter by committee
Search results
-
Residual accelerator chemicals in medical gloves appear to be a leading cause of allergic contact dermatitis in health care workers. A new ASTM International standard allows rubber glove manufacturers to monitor the level of residual chemicals in their end products and to potentially make manufacturing changes to reduce allergen levels. The new standard, D7558 , Test Method for Colorimetric/…
-
ASTM International Committee E29 on Particle and Spray Characterization has recently approved an extensive revision of ASTM standard E11 , Specification for Wire Cloth and Sieves for Testing Purposes. The revision will lead to better control of the quality of sieve cloths and test sieves. ASTM E11 is under the jurisdiction of Subcommittee E29.01 on Sieves, Sieving Methods and Screening Media.…
-
Once approved, a proposed new ASTM standard would provide the U.S. Food and Drug Administration and personal lubricant manufacturers a means to evaluate the effect of a lubricant on the physical integrity of condoms. No standard currently exists for this type of testing. Manufacturers of condoms and rubber gloves as well as personal lubricants are welcome to join in the development of ASTM…
-
The growing number and severity of healthcare association infections has increased interest in standardization efforts for antimicrobial gloves. In order to explore this area, ASTM International Committee D11 on Rubber has created a new task group on antimicrobial medical gloves. Glove suppliers, manufacturers and distributors, as well as contract test labs, government agency…
-
Responding to requests from the food service industry, ASTM International Committee D11 on Rubber has developed and approved a new standard, D7329 , Specification for Food Preparation and Food Handling (Food Service) Gloves. The new standard, under the jurisdiction of Subcommittee D11.40 on Consumer Rubber Products, will serve as a referee and guide to glove manufacturers, distributors and the…
-
Testing for potent allergens in rubber is the purpose of a proposed new ASTM standard. WK16334 , Test Method for the Immunological Measurement of Four Principal Allergenic Protein (Hev b 1, 3, 5 and 6.02) in Natural Rubber and Its Products, is being developed by Subcommittee D11.40 on Consumer Rubber Products, part of ASTM International Committee D11 on Rubber. According to Timo Palosuo and…
-
ASTM International Committee F16 on Fasteners has recently approved an important new standard that deals with coated threaded fasteners and washers by hot-dip zinc galvanizing. The standard, F 2329, Specification for Zinc Coating, Hot-Dip, Requirements for Application to Carbon and Alloy Steel Bolts, Screws, Washers, Nuts and Special Threaded Fasteners, is under the jurisdiction of Subcommittee…
-
Sieve manufacturers produce testing sieves using various sizes of wire cloth, per ASTM International standard E 11, Specification for Wire Cloth and Sieves for Testing Purposes. They also use ASTM standards E 161, Specification for Precision Electroformed Sieves, and E 323, Specification for Perforated-Plate Sieves for Testing Purposes when producing sieves from perforated plate. These…
-
ASTM International Committee F16 on Fasteners has developed a new standard, F 2329, Specification for Zinc Coating, Hot-Dip, Requirements for Application to Carbon and Alloy Steel Bolts, Screws, Washers, Nuts, and Special Threaded Fasteners. The standard, which is under the jurisdiction of Subcommittee F16.03 on Coatings on Fasteners, covers the requirements for hot-dip zinc coating applied to…
-
Two new ASTM International standards, F 2412, Test Methods for Foot Protection, and F 2413, Specification for Performance Requirements for Protective Footwear, have replaced the former ANSI Z41 standard, Standard for Personal Protection Protective Footwear, which has now been withdrawn. Both of the new ASTM standards are under the jurisdiction of ASTM Committee F13 on Pedestrian/Walkway Safety…