Residual accelerator chemicals in medical gloves appear to be a leading cause of allergic contact dermatitis in health care workers. A new ASTM International standard allows rubber glove manufacturers to monitor the level of residual chemicals in their end products and to potentially make manufacturing changes to reduce allergen levels. The new standard, D7558 , Test Method for Colorimetric/…
-
Arc protective blankets are used in many electrical applications to protect workers who are stationed near energized electrical parts. While these blankets have been used for years, there have been no testing criteria for their evaluation. A new ASTM International standard will be used to determine the effectiveness of arc protective blankets in suppressing the combined effect of an arc flash and…
-
Once approved, a proposed new ASTM standard would provide the U.S. Food and Drug Administration and personal lubricant manufacturers a means to evaluate the effect of a lubricant on the physical integrity of condoms. No standard currently exists for this type of testing. Manufacturers of condoms and rubber gloves as well as personal lubricants are welcome to join in the development of ASTM…
-
No industry standard currently exists that addresses the vacuum sealing requirements of knife-edged flanges for high vacuum applications. Existing international standards focus on interchangeability of the hardware, but do not address the reliability of the seal. ASTM International Committee E42 on Surface Analysis is now working on a proposed standard on the subject, WK21206 , Specification…
-
A 2002 workshop on galling wear held by ASTM International Committee G02 on Wear and Erosion provided the impetus for the development of a new standard, ASTM G196 , Test Method for Galling Resistance of Material Couples. The new standard is under the jurisdiction of Subcommittee G02.40 on Non-Abrasive Wear. According to Scott Hummel, Ph.D., associate professor, head of the department of…
-
The growing number and severity of healthcare association infections has increased interest in standardization efforts for antimicrobial gloves. In order to explore this area, ASTM International Committee D11 on Rubber has created a new task group on antimicrobial medical gloves. Glove suppliers, manufacturers and distributors, as well as contract test labs, government agency…
-
Responding to requests from the food service industry, ASTM International Committee D11 on Rubber has developed and approved a new standard, D7329 , Specification for Food Preparation and Food Handling (Food Service) Gloves. The new standard, under the jurisdiction of Subcommittee D11.40 on Consumer Rubber Products, will serve as a referee and guide to glove manufacturers, distributors and the…
-
Testing for potent allergens in rubber is the purpose of a proposed new ASTM standard. WK16334 , Test Method for the Immunological Measurement of Four Principal Allergenic Protein (Hev b 1, 3, 5 and 6.02) in Natural Rubber and Its Products, is being developed by Subcommittee D11.40 on Consumer Rubber Products, part of ASTM International Committee D11 on Rubber. According to Timo Palosuo and…
-
A new ASTM International standard, F 2621 , Practice for Determining Response Characteristics and Design Integrity of Arc Related Finished Products in an Electric Arc Exposure, is the latest in a series of standards developed by Subcommittee F18.65 on Wearing Apparel to reduce the number of fatalities and injuries caused by electric arcs. ASTM Practice F 2621 provides procedural guidelines for…