If you have a roof over your head, chances are very good that you have flashing over your head as well. Flashing serves as part of the weather resistant barrier systems that keep water from getting into a structure. A proposed new ASTM International guide will satisfy a market need for a standard to define durable flashing and will create a level playing field for flashing manufacturers. The…, ASTM Committee D08 Next Meeting:, Dec. 7-10, December Committee Week, New Orleans, La., Technical Contact:, Michael Schmeida, Oatey Co., Cleveland, Ohio, tel +1.216.898.3469; mschmeida@oatey.com, ASTM Staff Contact:, Joseph Hugo, tel +1.610.832.9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, tel +1.610.832.9603; bschindl@astm.org Release #9694
-
Excess moisture trapped in roofing or waterproofing systems can adversely affect performance, as well as lead to premature failure of a system and its components. Using an electrical impedance scanner is a fast and relatively easy way to conduct moisture surveys of roofing and waterproofing systems. A new ASTM International standard covers the use of electrical impedance scanners to monitor the…, ASTM Committee D08 Next Meeting:, Dec. 7-10, 2014, December Committee Week, New Orleans, La., Technical Contact:, Sean Fallon, Sean Fallon Consulting, Dublin, Ireland, Phone: +353-1-2851861; seanfallon14@gmail.com , ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9674
-
A proposed new ASTM standard will be used to ensure that the waterproofing of buildings is performing as intended. Once approved, the practice will be useful to architects, specifiers, membrane manufacturers, roofing contractors and warranty providers, as well as building owners, to test, verify and monitor the integrity of waterproof membranes. ASTM WK27666, Practice for Electrical Conductance…, ASTM Committee D08 Next Meeting:, June 22-25, 2014, June Committee Week, Toronto, Ontario, Canada, Technical Contact:, David Vokey, Detec Systems, Bellingham, Wash.; Phone: 360-961-9452; david.vokey@detecsystems.com , ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9593
-
A new ASTM International standard will provide a qualitative means to determine the potential effect of plasticizers contained within polyvinylchloride floor covering materials on a specific adhesive. ASTM D7888 , Practice for Evaluating Adhesive and the Effects of Plasticizer Found Within Polyvinylchloride-Backed Floor Coverings, was developed by Subcommittee D14.10 on Working Properties, part…, ASTM Committee D14 Next Meeting:, April 6-8, 2014, April Committee Week, Toronto, Ontario, Canada, Technical Contact:, Larry Press, Helmitin Adhesives Inc., Jacksonville, Fla., Phone: 904-765-2364; l.press@helmit inadehesives.com , ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9533
-
For more than 100 years, cork tile has been commonly used as a floor and wall covering for residential and commercial use. A new ASTM International standard, ASTM F3008 , Specification for Cork Floor Tile, specifies requirements for cork floor coverings made from agglomerated composition cork supplied in tile form, which is designed to be used with a factory finish or an in situ finish, or both.…, ASTM Committee F06 Next Meeting:, May 7-8, 2014, Clearwater, Fla., Technical Contact:, Christopher Capobianco, Spartan Surfaces, Patchogue, N.Y., Phone: 631-275-6494; christopher@spartansurfaces.com, ASTM Staff Contact:, Stephen Mawn, Phone: 610-832-9726; smawn@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9523
-
ASTM International Committee D08 on Roofing and Waterproofing , through its Subcommittee D08.24 on Sustainability , is developing several standards for sustainable roofing systems. One such standard is ASTM WK26599 , Guide for Design of Sustainable, Low-Slope Roofing Systems. “The proposed standard embraces the fact that the primary purpose of the roofing system is to protect the top of the…, ASTM Committee D08 Next Meeting:, Dec. 8-11, 2013, December Committee Week, Jacksonville, Fla., Technical Contact:, Eric K. Olson, P.E., Simpson Gumpertz & Heger, Waltham, Mass., Phone: 781-907-9311; ekolson@sgh.com, ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9478
-
A proposed ASTM standard will reflect recent technological advances for asphalt adhesives. ASTM WK40056 , Specification for Adhesive Used with Modified Bituminous Sheet Materials, is being developed by Subcommittee D08.20 on Roofing Membrane Systems , part of ASTM International Committee D08 on Roofing and Waterproofing . “The proposed standard will provide a means of describing the changes that…, ASTM Committee D08 Next Meeting:, June 9-12, 2013, June Committee Week, Indianapolis, Ind., Technical Contact:, Carter C. Slusher, Firestone Building Products, Indianapolis, Ind., Phone: 317-575-7117; slushercarter@gbsg.net, ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9322
-
ASTM International Committee E11 on Quality and Statistics has approved the last in a series of ASTM standards that preserve military sampling standards that were originally under the jurisdiction of the U.S. Department of Defense. The new standard, ASTM E2910 , Guide for Preferred Methods for Acceptance of Product, preserves MIL-STD-1916 in its original form. ASTM E2910 is under the jurisdiction…, ASTM Committee E11 Next Meeting:, May 8-10, 2013, ASTM International Headquarters, West Conshohocken, Pa., Technical Contact:, Dean V. Neubauer, Corning, Inc., Corning, N.Y., Phone: 607-974-6777; neubauerdv@corning.com, ASTM Staff Contact:, Katerina Koperna, Phone: 610-832-9728; kkoperna@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9317
-
A recently published ASTM International standard covers a new type of resilient flooring tile product based on a polyester binder. ASTM F2982 , Specification for Polyester Composition Floor Tile, was developed by Subcommittee F06.80 on Specifications , part of ASTM International Committee F06 on Resilient Floor Coverings . “ ASTM F2982 sets forth an explicit set of compositional and performance…, ASTM Committee F06 Next Meeting:, May 22-23, 2013, May Committee Week, Indianapolis, Ind., Technical Contact:, Thomas Erisman, Armstrong World Industries, Lancaster, Pa., Phone: 717-396-5354; tcerisman@armstrong.com, ASTM Staff Contact:, Stephen Mawn, Phone: 610-832-9726; smawn@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9271
-
Many manufacturers have their own methods for testing adhesives for carpet or resilient or wood floor coverings. A new ASTM standard addresses this inconsistency by presenting a set of adhesive requirements that can be used throughout the floor covering industry. The new standard, ASTM D7799 , Specification for Tufted and Woven Broadloom Carpet Adhesives Without Homogenous PVC or Non-PVC Backings…