Search
Advanced search
Filter by category
Filter by committee
Search results
-
Keeping used materials out of landfills is a central goal of any industry that is attempting to become more sustainable. Finding creative ways to repurpose these materials is an added challenge, but one that ASTM International Committee D08 on Roofing and Waterproofing has begun to tackle with a proposed new standard, ASTM WK46625 , Guide for Establishing a Recycle Program for Roof Covers. “With…, ASTM Committee D08 Next Meeting:, Dec. 7-10, December Committee Week, New Orleans, La., Technical Contact:, Joseph J. Schwetz, tel +1.781.332.3224; schwetz.joe@us.sika.com, ASTM Staff Contact:, Joseph Hugo, tel +1.610.832.9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, tel +1.610.832.9603; bschindl@astm.org Release #9709
-
If you have a roof over your head, chances are very good that you have flashing over your head as well. Flashing serves as part of the weather resistant barrier systems that keep water from getting into a structure. A proposed new ASTM International guide will satisfy a market need for a standard to define durable flashing and will create a level playing field for flashing manufacturers. The…, ASTM Committee D08 Next Meeting:, Dec. 7-10, December Committee Week, New Orleans, La., Technical Contact:, Michael Schmeida, Oatey Co., Cleveland, Ohio, tel +1.216.898.3469; mschmeida@oatey.com, ASTM Staff Contact:, Joseph Hugo, tel +1.610.832.9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, tel +1.610.832.9603; bschindl@astm.org Release #9694
-
Excess moisture trapped in roofing or waterproofing systems can adversely affect performance, as well as lead to premature failure of a system and its components. Using an electrical impedance scanner is a fast and relatively easy way to conduct moisture surveys of roofing and waterproofing systems. A new ASTM International standard covers the use of electrical impedance scanners to monitor the…, ASTM Committee D08 Next Meeting:, Dec. 7-10, 2014, December Committee Week, New Orleans, La., Technical Contact:, Sean Fallon, Sean Fallon Consulting, Dublin, Ireland, Phone: +353-1-2851861; seanfallon14@gmail.com , ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9674
-
Cook-and-hold ovens allow users to cook food at one temperature and then hold it at a preprogrammed lower temperature. The kitchen staffs at steakhouses, schools and hotels all cook with such ovens. A new ASTM International standard, ASTM F3051 , Test Method for Performance of Cook-and-Hold Ovens, provides a test to gauge oven energy usage. “Since many cook-and-hold units run overnight, end users…, ASTM Committee F26 Next Meeting:, Oct. 7-8, 2014, October Committee Week, New Orleans, La., Technical Contact:, Andre Saldivar, SCE Foodservice Technology Center, Irwindale, Calif., Phone: 626-812-7558; andre.saldivar@sce.com , ASTM Staff Contact:, Kristy Straiton, Phone: 610-832-9640; kstraiton@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9672
-
A proposed new ASTM standard will be used to ensure that the waterproofing of buildings is performing as intended. Once approved, the practice will be useful to architects, specifiers, membrane manufacturers, roofing contractors and warranty providers, as well as building owners, to test, verify and monitor the integrity of waterproof membranes. ASTM WK27666, Practice for Electrical Conductance…, ASTM Committee D08 Next Meeting:, June 22-25, 2014, June Committee Week, Toronto, Ontario, Canada, Technical Contact:, David Vokey, Detec Systems, Bellingham, Wash.; Phone: 360-961-9452; david.vokey@detecsystems.com , ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9593
-
ASTM International Committee D08 on Roofing and Waterproofing , through its Subcommittee D08.24 on Sustainability , is developing several standards for sustainable roofing systems. One such standard is ASTM WK26599 , Guide for Design of Sustainable, Low-Slope Roofing Systems. “The proposed standard embraces the fact that the primary purpose of the roofing system is to protect the top of the…, ASTM Committee D08 Next Meeting:, Dec. 8-11, 2013, December Committee Week, Jacksonville, Fla., Technical Contact:, Eric K. Olson, P.E., Simpson Gumpertz & Heger, Waltham, Mass., Phone: 781-907-9311; ekolson@sgh.com, ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9478
-
A proposed ASTM standard will reflect recent technological advances for asphalt adhesives. ASTM WK40056 , Specification for Adhesive Used with Modified Bituminous Sheet Materials, is being developed by Subcommittee D08.20 on Roofing Membrane Systems , part of ASTM International Committee D08 on Roofing and Waterproofing . “The proposed standard will provide a means of describing the changes that…, ASTM Committee D08 Next Meeting:, June 9-12, 2013, June Committee Week, Indianapolis, Ind., Technical Contact:, Carter C. Slusher, Firestone Building Products, Indianapolis, Ind., Phone: 317-575-7117; slushercarter@gbsg.net, ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9322
-
A new ASTM International standard provides information and guidelines for the selection and installation of drainage systems media that are used with waterproofing systems. ASTM D7492/D7492M , Guide for Use of Drainage System Media with Waterproofing Systems, was developed by Subcommittee D08.22 on Waterproofing and Dampproofing Systems, part of ASTM International Committee D08 on Roofing and…
-
A new ASTM International standard, adopted from an American Concrete Institute test method, will be used to help ensure the safety of construction projects. ASTM C1741 , Test Method for Bleed Stability of Cementitious Post-Tensioning Tendon Grout, is under the jurisdiction of Subcommittee C09.41 on Hydraulic Cement Grouts , part of ASTM International Committee C09 on Concrete and Concrete…
-
Piston ring/liner interface can contribute as much as half the total friction loss in internal combustion engines, with the resulting wear leading to reduced energy efficiency and raised emissions. A new ASTM International standard provides a method to more accurately measure small amounts of wear on curved piston ring segments and their counterfaces after lubricated bench-scale testing. “Coupled…