Search
Advanced search
Filter by category
Filter by committee
Search results
-
An important ASTM engine coolant standard, ASTM D3321 , Test Method for Use of the Refractometer for Field Test Determination of the Freezing Point of Aqueous Engine Coolants, has recently been revised to reflect advances in engine coolant technology used in modern engines. ASTM D3321 is under the jurisdiction of Subcommittee D15.03 on Physical Properties , part of ASTM International Committee…, ASTM Committee D15 Next Meeting:, May 21-22, 2013, May Committee Week, Indianapolis, Ind., Technical Contact:, Frederick C. Alverson, Shell Global Solutions, Houston, Texas, Phone: 281-544-9217; frederick.alverson@shell.com, ASTM Staff Contact:, Joe Koury, Phone: 610-832-9804; jkoury@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9274
-
ASTM International Committee G01 on Corrosion of Metals has an ongoing commitment to help the oil field industries adopt and use state-of-the-art techniques to control corrosion. As part of this commitment, Subcommittee G01.05 on Laboratory Corrosion Tests has approved ASTM G205 , Guide for Determining Corrosivity of Crude Oils. ASTM G205 is the result of collaboration among members of Task Group…, ASTM Committee G01 Next Meeting:, Nov. 13-15, November Committee Week, Atlanta, Ga., Technical Contact:, Sankara Papavinasam, Ph.D., CanmetMATERIALS, Hamilton, Ontario, Canada, Phone: 613-947-4603; spapavin@nrcan.gc.ca, ASTM Staff Contact:, Jennifer Rodgers, Phone: 610-832-9694; jrodgers@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9297
-
A proposed new ASTM International standard will detail a multilevel approach for performing above- and below-ground inspection of transmission poles and lattice towers in the field. ASTM WK35986, Test Method for Field Inspection of Transmission Poles and Lattice Towers, will be used by utilities to provide tools for maintenance departments that inspect and repair transmission structures. ASTM…
-
A proposed new ASTM International standard will allow for a rapid and highly repeatable determination of chlorine in coal and coke through X-ray fluorescence spectroscopy. ASTM WK34943 , Test Method for Chlorine in Coal and Coke by XRF, is being developed by Subcommittee D05.29 on Major Elements in Ash and Trace Elements of Coal , which is part of ASTM International Committee D05 on Coal and Coke…, ASTM Committee D05 Next Meeting:, May 13-15, 2012, ASTM Headquarters, West Conshohocken, Pa., Technical Contact:, Colin Campbell, SaskPower, Regina, Saskatchewan, Canada, Phone: 306-566-2292; ccampbell@saskpower.com, ASTM Staff Contact:, Scott Orthey, Phone: 610-832-9730; sorthey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9110
-
Once approved, a proposed new ASTM International standard will aid in the evaluation of high performance protective coatings for sewerage systems. The proposed standard will provide a test specific to these coatings. Subcommittee G01.05 on Laboratory Corrosion Tests is developing ASTM WK33537 , Practice for Operating the Severe Wastewater Analysis Testing Apparatus. G01.05 is under the…, ASTM Committee G01 Next Meeting:, Nov. 16-17, 2011, November Committee Week, Tampa, Fla., Technical Contact:, Vaughn O’Dea, Tnemec Co. Inc., Kansas City, MO, Phone: 816-519-2267; odea@tnemec.com, ASTM Staff Contact:, Jennifer Rodgers, Phone: 610-832-9694; jrodgers@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8977
-
A proposed new standard on determining the total amount of fluorine and chlorine in coal and coke will be useful to those working with power plant boilers as well as by those in government and industry who are trying to model the release of anions into the environment. The proposed new standard, ASTM WK33343 , Test Method for Total Fluorine and Chlorine in Coal, Coke and their Residues by…
-
A new ASTM International standard will provide a method of testing corrosion-resistant fasteners and their performance in contact with treated wood. ASTM G198 , Test Method for Determining the Relative Corrosion Performance of Driven Fasteners in Contact with Treated Wood, was developed by Subcommittee G01.14 on Corrosion of Metals in Construction Materials , part of ASTM International Committee…
-
New ASTM Vitrinite Reflectance Standard Will Aid in Prediction of Undiscovered Hydrocarbon ResourcesA new ASTM International standard for measuring the reflectance of vitrinite in sedimentary rocks will help improve predictions of the location, quantity and quality of undiscovered hydrocarbon resources. ASTM D7708 , Test Method for Microscopical Determination of the Reflectance of Vitrinite Dispersed in Sedimentary Rocks, was developed by Subcommittee D05.28 on Petrographic Analysis of Coal and…, ASTM Committee D05 Next Meeting:, Oct. 30-Nov. 2, 2011, October Committee Week, Tampa, Fla., Technical Contact:, Paul C. Hackley, U.S. Geological Survey, Reston, Va., Phone: 703-648-6458; phackley@usgs.gov, ASTM Staff Contact:, Scott Orthey, Phone: 610-832-9730; sorthey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8881
-
ASTM International Committee D15 on Engine Coolants has formed three new subcommittees: Subcommittees D15.22 on Non-Aqueous Coolants ; D15.25 on Diesel Exhaust Fluid ; and D15.30 on Industrial Heat Transfer Fluids . All interested parties are invited to join in the standards developing activities of these new subcommittees., D15.22, Non-Aqueous Coolants, While there has been an increased interest in non-aqueous coolants industry, there are no current ASTM standards in this area. D15.22 will begin to develop such standards. “The envisioned standards for non-aqueous coolants would be performance standards, rather than ingredient standards, to allow for formulations that are not currently proprietary,” says Jonathan T. Light, chief engineer, Evans…, D15.25, Diesel Exhaust Fluid, Diesel exhaust fluid, often referred to as DEF, is required by many diesel engine-powered vehicles delivered after January 2010. More recent environmental standards issued by the U.S. Environmental Protection Agency have created more stringent emissions standards for agricultural, construction and forestry equipment. DEF is used to reduce nitrogen oxide emissions, which allows original equipment…, D15.30, Industrial Heat Transfer Fluids, Members of D15 recognized that changes in the antifreeze industry, including new manufacturing technologies, improved inhibitor chemistries and recycling technologies, would likely be adapted to the facilities industry as a natural course of innovation. Because D15 has experience developing standards that are technically similar to the facilities heat transfer industry, it was deemed appropriate…, ASTM Committee D15 Next Meeting:, May 17-18, May Committee Week, Anaheim, Calif., Technical Contact:, (D15.22) Jonathan T. Light, Evans Cooling Systems Inc., Sharon, Conn., Phone: 860-435-2418; jtlight@comcast.net ; (D15.25) Edward Eaton Sr., Amalgatech, Phoenix, Ariz., Phone: 602-252-0280; edeaton@amalgatech.com ; (D15.30) John Panasewicz, Clear Choice Antifreeze, Henderson, Colo., Phone: 303-227-9900; johnp@clearchoiceantifreeze.com, ASTM Staff Contact:, Joe Koury, Phone: 610-832-9804; jkoury@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8837
-
Natural gas from unconventional sources such as coal beds has become a common target of exploration. Now, a new ASTM standard is the first to describe a method for determining the gas content of coal from such sources by desorption, using samples obtained by surface drilling. ASTM D7569 , Practice for Determination of Gas Content of Coal - Direct Desorption Method, was developed by Subcommittee…, ASTM Committee D05 Next Meeting:, May 15-18, 2011, May Committee Week, Anaheim, Calif., Technical Contact:, Peter Warwick, U.S. Geological Survey, Reston, Va., Phone: 703-648-6469; pwarwick@usgs.gov, ASTM Staff Contact:, Scott Orthey, Phone: 610-832-9730; sorthey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8749