Excess moisture trapped in roofing or waterproofing systems can adversely affect performance, as well as lead to premature failure of a system and its components. Using an electrical impedance scanner is a fast and relatively easy way to conduct moisture surveys of roofing and waterproofing systems. A new ASTM International standard covers the use of electrical impedance scanners to monitor the…, ASTM Committee D08 Next Meeting:, Dec. 7-10, 2014, December Committee Week, New Orleans, La., Technical Contact:, Sean Fallon, Sean Fallon Consulting, Dublin, Ireland, Phone: +353-1-2851861; seanfallon14@gmail.com , ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9674
-
Taking a tape-lift sample is one of the main practices used by indoor environmental quality investigators for detecting whether mold structures (for example, spores and hyphae) have either settled onto or colonized the surface. Despite the popularity of the method, there can be significant inconsistency in how tape lifts are collected. A new ASTM standard, ASTM D7910 , Practice for the Collection…, ASTM Committee D22 Next Meeting:, Oct. 5-8, 2014, October Committee Week, New Orleans, La., Technical Contact:, John M. Neville, Ph.D., Bureau Veritas North America Inc., Novi, Mich., Phone: 248-344-3042; john.neville@us.bureauveritas.com, ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9655
-
A new standard, ASTM D7886 , Practice for Asbestos Exposure Assessments for Repetitive Maintenance and Installation Tasks, will aid those testing asbestos exposures by quantifying such exposure levels. Regulations set forth by the U.S. Occupational Safety and Health Administration require that worker exposure to asbestos be determined with a “high level of certainty.” “ASTM D7886 overcomes the…, ASTM Committee D22 Next Meeting:, Oct. 5-8, 2014, October Committee Week, New Orleans, La., Technical Contact:, Andrew F. Oberta, MPS, CIH, The Environmental Consultancy, Austin, Texas, Phone: 512-266-1368; andyobe@aol.com , ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9639
-
A proposed new ASTM standard will be used to ensure that the waterproofing of buildings is performing as intended. Once approved, the practice will be useful to architects, specifiers, membrane manufacturers, roofing contractors and warranty providers, as well as building owners, to test, verify and monitor the integrity of waterproof membranes. ASTM WK27666, Practice for Electrical Conductance…, ASTM Committee D08 Next Meeting:, June 22-25, 2014, June Committee Week, Toronto, Ontario, Canada, Technical Contact:, David Vokey, Detec Systems, Bellingham, Wash.; Phone: 360-961-9452; david.vokey@detecsystems.com , ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9593
-
Gaseous hydrogen fluoride is a harsh respiratory irritant; the inhalation of hydrofluoric acid mists causes severe lung damage in exposed workers. A proposed new ASTM standard, WK38734 , Test Method for the Determination of Particulate Fluorides and Hydrofluoric Acid Using Filter Sampling and Suppressed Ion Chromatography, will be used to prevent overexposure of hydrofluoric acid/hydrogen…, ASTM Committee D22 Next Meeting:, Oct. 5-8, 2014, October Committee Week, New Orleans, La., Technical Contact:, Dietmar Breuer, IFA, Sankt Augustin, Germany, Phone: +49 (0) 2241 231-2533; dietmar.breuer@dguv.de , ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9585
-
While monitoring air quality is important in many situations, a variety of different quantitative passive samplers are available for such work. A proposed new ASTM standard, ASTM WK45755 , Guide for Selection of Quantitative Passive Samplers for Volatile Organic Compounds in Air, will help users decide which air sampler type will best suit their needs. ASTM WK45755 will cover issues such as the…, ASTM Committee D22 Next Meeting:, Oct. 5-8, 2014, October Committee Week, New Orleans, La., Technical Contact:, Nicola Watson, Markes International, Loveland, Ohio, Phone: 513-488-6161; nwatson@markes.com , ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9578
-
A proposed new ASTM International standard is emerging from research being conducted at the U.S. Bureau of Reclamation to identify and investigate coatings that will prevent the settlement and attachment of erosion-causing invasive species such as zebra and quagga mussels inside water and wastewater pipelines. The proposed standard, ASTM WK45207 , Test Method for Erosion of Coatings by Flowing…, ASTM Committee D01 Next Meeting:, June 22-24, 2014, in conjunction with ASTM International Committee D02 on Petroleum Products, Liquid Fuels and Lubricants meeting, Indianapolis, Ind., Technical Contact:, Daniel Libby, Chase Corp., Westwood, Mass., Phone: 781-332-0782; dlibby@chasecorp.com, ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9645
-
An ASTM subcommittee is developing a proposed standard to test the slip coefficient properties of coatings used in slip-critical bolted connections. The test is based on an appendix in the “Specification for Structural Joints Using High-Strength Bolts,” published by the Research Council on Structural Connections. The proposed ASTM standard will expand on the Research Council standard by…, ASTM Committee D01 Next Meeting:, June 22-24, 2014, Indianapolis, Ind., Technical Contact:, Bill Corbett, KTA-Tator Inc., Pittsburgh, Pa., Phone: 412-788-1300, ext. 223; bcorbett@kta.com , ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9638
-
ASTM International Committee D08 on Roofing and Waterproofing , through its Subcommittee D08.24 on Sustainability , is developing several standards for sustainable roofing systems. One such standard is ASTM WK26599 , Guide for Design of Sustainable, Low-Slope Roofing Systems. “The proposed standard embraces the fact that the primary purpose of the roofing system is to protect the top of the…, ASTM Committee D08 Next Meeting:, Dec. 8-11, 2013, December Committee Week, Jacksonville, Fla., Technical Contact:, Eric K. Olson, P.E., Simpson Gumpertz & Heger, Waltham, Mass., Phone: 781-907-9311; ekolson@sgh.com, ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9478
-
A new ASTM International standard describes a solvent rub technique that can be used in the laboratory, field or fabrication shop for assessing the solvent resistance of an organic coating that chemically and/or physically changes during the curing process. ASTM D7835 , Test Method for Determining the Solvent Resistance of an Organic Coating Using a Mechanical Rubbing Machine, was developed by…, ASTM Committee D01 Next Meeting:, Jan. 26-28, 2014, January Committee Week, Houston, Texas, Technical Contact:, Ted Best, Valspar Corp., Bowling Green, Ky., Phone: 270-746-6867; tbest@valspar.com , ASTM Staff Contact:, Jeff Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9447