A proposed ASTM standard will meet the need for a method that labs can follow when testing samples for mold. The proposed standard (WK17177, Test Method for Examination of Fungal Structures on Tape Lift Samples by Optical Microscopy) will provide labs with an approach based on quality and science. The primary users of the standard will be labs that provide services in the fields of occupational…, Committee D22 on Air Quality Next Meeting:, April 26-May 1, 2015, April committee week, Anaheim, Calif., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Terri L. Williams, Wisconsin Occupational Health Laboratory, University of Wisconsin, Madison, Wis., tel +1.608.224.6261; terri.williams@slh.wisc.edu, ASTM Staff Contact:, Jeffrey Adkins, tel +1.610.832.9738; jadkins@astm.org Release # 9797 March 17, 2015 ###
-
A new ASTM standard consolidates six current standards on structural fasteners. With hundreds of millions of fasteners produced to ASTM specifications each year, industry will benefit from the streamlined approach provided by the new ASTM standard ( F3125 : Specification for High Strength Structural Bolts, Steel and Alloy Steel, Heat Treated, 120 ksi (830 MPa) and150 ksi (1040 MPa) Minimum…, ASTM Committee F16 Next Meeting:, May 17-19, 2015, May committee week, Anaheim, Calif., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Chad Larson, LeJeune Bolt Co., Burnsville, Minn., tel +1.952.890.7700; clarson@lejeunebolt.com, ASTM Staff Contact:, Jennifer Rodgers, tel +1.610.832.9694; jrodgers@astm.org Release #9785 ###
-
Pigment manufacturers use the loss on ignition test to determine water of hydration or crystallized water. While loss on ignition is a frequently used test, its methodology is embedded within other standards and varies from one to another. Now, a proposed new standard, ASTM WK46877, Test Method for Pigment Loss on Ignition, will provide definitive instructions for conducting this common test. “…, ASTM Committee D01 Next Meeting:, Jan. 25-27, 2015, January Committee Week, New Orleans, La., Technical Contact:, Steven Brunner, WPC Technologies, Milwaukee, Wis., Phone: 414-225-2415; sbrunner@wpctech.com, ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9682
-
Taking a tape-lift sample is one of the main practices used by indoor environmental quality investigators for detecting whether mold structures (for example, spores and hyphae) have either settled onto or colonized the surface. Despite the popularity of the method, there can be significant inconsistency in how tape lifts are collected. A new ASTM standard, ASTM D7910 , Practice for the Collection…, ASTM Committee D22 Next Meeting:, Oct. 5-8, 2014, October Committee Week, New Orleans, La., Technical Contact:, John M. Neville, Ph.D., Bureau Veritas North America Inc., Novi, Mich., Phone: 248-344-3042; john.neville@us.bureauveritas.com, ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9655
-
A new standard, ASTM D7886 , Practice for Asbestos Exposure Assessments for Repetitive Maintenance and Installation Tasks, will aid those testing asbestos exposures by quantifying such exposure levels. Regulations set forth by the U.S. Occupational Safety and Health Administration require that worker exposure to asbestos be determined with a “high level of certainty.” “ASTM D7886 overcomes the…, ASTM Committee D22 Next Meeting:, Oct. 5-8, 2014, October Committee Week, New Orleans, La., Technical Contact:, Andrew F. Oberta, MPS, CIH, The Environmental Consultancy, Austin, Texas, Phone: 512-266-1368; andyobe@aol.com , ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9639
-
Gaseous hydrogen fluoride is a harsh respiratory irritant; the inhalation of hydrofluoric acid mists causes severe lung damage in exposed workers. A proposed new ASTM standard, WK38734 , Test Method for the Determination of Particulate Fluorides and Hydrofluoric Acid Using Filter Sampling and Suppressed Ion Chromatography, will be used to prevent overexposure of hydrofluoric acid/hydrogen…, ASTM Committee D22 Next Meeting:, Oct. 5-8, 2014, October Committee Week, New Orleans, La., Technical Contact:, Dietmar Breuer, IFA, Sankt Augustin, Germany, Phone: +49 (0) 2241 231-2533; dietmar.breuer@dguv.de , ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9585
-
While monitoring air quality is important in many situations, a variety of different quantitative passive samplers are available for such work. A proposed new ASTM standard, ASTM WK45755 , Guide for Selection of Quantitative Passive Samplers for Volatile Organic Compounds in Air, will help users decide which air sampler type will best suit their needs. ASTM WK45755 will cover issues such as the…, ASTM Committee D22 Next Meeting:, Oct. 5-8, 2014, October Committee Week, New Orleans, La., Technical Contact:, Nicola Watson, Markes International, Loveland, Ohio, Phone: 513-488-6161; nwatson@markes.com , ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9578
-
A proposed new ASTM International standard is emerging from research being conducted at the U.S. Bureau of Reclamation to identify and investigate coatings that will prevent the settlement and attachment of erosion-causing invasive species such as zebra and quagga mussels inside water and wastewater pipelines. The proposed standard, ASTM WK45207 , Test Method for Erosion of Coatings by Flowing…, ASTM Committee D01 Next Meeting:, June 22-24, 2014, in conjunction with ASTM International Committee D02 on Petroleum Products, Liquid Fuels and Lubricants meeting, Indianapolis, Ind., Technical Contact:, Daniel Libby, Chase Corp., Westwood, Mass., Phone: 781-332-0782; dlibby@chasecorp.com, ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9645
-
An ASTM subcommittee is developing a proposed standard to test the slip coefficient properties of coatings used in slip-critical bolted connections. The test is based on an appendix in the “Specification for Structural Joints Using High-Strength Bolts,” published by the Research Council on Structural Connections. The proposed ASTM standard will expand on the Research Council standard by…, ASTM Committee D01 Next Meeting:, June 22-24, 2014, Indianapolis, Ind., Technical Contact:, Bill Corbett, KTA-Tator Inc., Pittsburgh, Pa., Phone: 412-788-1300, ext. 223; bcorbett@kta.com , ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9638
-
A new ASTM International standard describes a solvent rub technique that can be used in the laboratory, field or fabrication shop for assessing the solvent resistance of an organic coating that chemically and/or physically changes during the curing process. ASTM D7835 , Test Method for Determining the Solvent Resistance of an Organic Coating Using a Mechanical Rubbing Machine, was developed by…, ASTM Committee D01 Next Meeting:, Jan. 26-28, 2014, January Committee Week, Houston, Texas, Technical Contact:, Ted Best, Valspar Corp., Bowling Green, Ky., Phone: 270-746-6867; tbest@valspar.com , ASTM Staff Contact:, Jeff Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9447