Search
Advanced search
Filter by category
Filter by committee
Search results
-
Rotational viscometry is an easily used tool for determining the viscosity of fluids, including paints, petroleum products and polymer solutions. While standards often make use of rotational viscometry, a procedure for calibrating or validating the measurement is not always part of the standard, which could lead to results that differ from one laboratory to another. A proposed user viscosity…, ASTM Committee E37 Next Meeting:, March 14, 2014, ASTM International Headquarters, West Conshohocken, Pa., Technical Contact:, Roger Blaine, Corvallis, Ore., Phone: 302-559-6827; roger.l.blaine@gmail.com, ASTM Staff Contact:, Tom O'Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9493
-
Rheologists are encouraged to join in the development of a proposed new practice that will help standardize calibration of rotational rheometers to obtain accurate normal force measurements. ASTM WK33687 , Practice for Normal Force Calibration for Rotational Rheometers, is being developed by Subcommittee E37.08 on Rheology , part of ASTM International Committee E37 on Thermal Measurements . The…, ASTM Committee E37 Next Meeting:, Aug. 10-11, in conjunction with the North American Thermal Analysis Society Annual Conference, Des Moines, Iowa, Technical Contact:, Kenneth Aniunioh, Shimadzu Scientific Instruments, Laurel, Md., Phone: 864-633-7690; kenebaano@yahoo.com, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8923
-
ASTM E2369 Provides Means for Healthcare Workers to Collect and Transfer Patient Data The Office of the National Coordinator for Health Information Technology (ONC), part of the United States Department of Health and Human Services, has included an ASTM International standard as part of its formal certification criteria for electronic health record (EHR) technologies. The standard, ASTM E2369…
-
An ASTM International standard used for effective and timely electronic messaging of health care records has now been adopted as a standard for structured summary health record exchange included in new regulations associated with the Health Information Technology for Economic and Clinical Health Act provision of the American Recovery and Reinvestment Act of 2009 (ARRA/HITECH). ASTM E2369 ,…, Technical Contact:, Dr. David C. Kibbe, The Kibbe Group L.L.C., Pittsboro, N.C. Phone: 913-205-7968; kibbedavid@mac.com, ASTM Staff Contact:, Dan Smith, Staff Manager , Phone: 610-832-9727; dsmith@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8451/Jan2010
-
The ASTM International Proficiency Testing Center is pleased to offer a 2010 Proficiency Testing Program on Thermal Analyses of Plastics (TAP) to laboratories who need a statistical quality assurance tool that will enable them to improve and maintain a high level of performance in conducting ASTM Differential Scanning Calorimetry (DSC), Oxidative-Induction Time (OIT) by Differential Scanning…, ASTM D3418, , Standard Test Method for Transition Temperatures and Enthalpies of Fusion and Crystallization of Polymers by Differential Scanning Calorimetry (DSC);, ASTM D3850, , Standard Test Method for Rapid Thermal Degradation of Solid Electrical Insulating Materials By Thermogravimetric Method (TGA); and, ASTM D3895, , Standard Test Method for Oxidative-Induction Time of Polyolefins by Differential Scanning Calorimetry. For each test trial, laboratory participants receive two sample materials along with interactive electronic data report forms and test instructions. Using the specified ASTM program tests, participating laboratories conduct the tests of their choice that they routinely run. Upon completion of…
-
Honeycomb ceramics, porous with linear hollow channels, are being used worldwide in automotive catalytic converters and as diesel particulate filters for trucks. Flexural testing of this type of ceramics is addressed in a new ASTM International standard, ASTM C1674 , Test Method for Flexural Strength of Advanced Ceramics with Engineered Porosity (Honeycomb Cellular Channels) at Ambient…
-
ASTM International Committee E31 on Healthcare Informatics notes the innovative use of the Continuity of Care Record within the Google Health application launched on May 20. Formally known as ASTM E2369 , Specification for Continuity of Care (CCR), the CCR standard is an XML-based format for access to, transport of and interoperable exchange of core summary health information. The CCR is intended…
-
New Advanced Ceramics Standards from ASTM Cover Fracture Mirror Size Analysis, Tensile Strength DataSubcommittee C28.01 on Mechanical Properties and Performance, part of ASTM International Committee C28 on Advanced Ceramics, has recently approved two new standards, ASTM C1678 , Practice for Fractographic Analysis of Fracture Mirror Sizes in Ceramics and Glasses, and ASTM C1683 , Practice for Size Scaling of Tensile Strengths Using Weibull Statistics for Advanced Ceramics., ASTM C1678 —Bringing Consistency to Fracture Mirror Size Analysis, Fracture mirror size analysis is a powerful quantitative tool for the interpretation of broken ceramic and glass articles. While this type of analysis can be used to determine the stress in a part at the instant of fracture, inspection and interpretation procedures have often varied, resulting in uncertainty in stress estimates. ASTM C1678, Practice for Fractographic Analysis of Fracture Mirror…, ASTM C1683 —Scaling Strength Values, ASTM C1683, Practice for Size Scaling of Tensile Strength Using Weibull Statistics for Advanced Ceramics, provides methodology to convert fracture strength parameters estimated from data obtained with one test geometry to strength parameters representing other test geometries. Stephen Duffy, chair of civil engineering, Cleveland State University, and C28 member, says that companies producing…
-
ASTM International and AIIM, the international authority on Enterprise Content Management, have now published the Best Practices Guide – PDF Healthcare ( AIIM/ASTM BP-01-2008 ). This document describes a proposed, voluntary, industry-wide reference tool and guideline to describe the features and functionality of the Portable Document Format (PDF) for the healthcare industry. It is designed to…
-
Ceramic and glass companies, as well as universities and government laboratories, will be the primary users of a new ASTM standard that allows for the flexural strength determination of components made in a round shape or after finish machining with minimal waste. The standard, ASTM C1684 , Test Method for Flexural Strength of Advanced Ceramics at Ambient Temperature-Cylindrical Rod Strength, was…