Search
Advanced search
Filter by category
Filter by committee
Search results
-
A new ASTM International standard, adopted from an American Concrete Institute test method, will be used to help ensure the safety of construction projects. ASTM C1741 , Test Method for Bleed Stability of Cementitious Post-Tensioning Tendon Grout, is under the jurisdiction of Subcommittee C09.41 on Hydraulic Cement Grouts , part of ASTM International Committee C09 on Concrete and Concrete…
-
Piston ring/liner interface can contribute as much as half the total friction loss in internal combustion engines, with the resulting wear leading to reduced energy efficiency and raised emissions. A new ASTM International standard provides a method to more accurately measure small amounts of wear on curved piston ring segments and their counterfaces after lubricated bench-scale testing. “Coupled…
-
ASTM Committee G02 on Wear and Erosion is including a field trip in the plans for its Dec. 8-9 meeting in Jacksonville, Fla. Committee members will be visiting the Tribology Laboratory in the mechanical engineering department at the University of Florida in Gainesville. The Tribology Laboratory is actively involved in a wide variety of tribological research and tribology education projects. The…
-
ASTM International Committee E56 on Nanotechnology has created a new subcommittee, E56.06 on Nano-Enabled Consumer Products. The scope of E56.06 is to develop scientifically credible standards for identification, evaluation and assessment of engineered nanomaterials in consumer products. Members of E56.06 will develop standards for determining the presence of engineered nanomaterials in consumer…, ASTM Committee E56 Next Meeting:, Nov 15-16, November Committee Week, San Antonio, Texas, Technical Contact:, (Chairman, E56) Debbie Kaiser, National Institute of Standards and Technology, Gaithersburg, Md., Phone: 301-975-6759; debra.kaiser@nist.gov ; (Subcommittee E56.06) Aleks Stefaniak, National Institute for Occupational Safety and Health, Morgantown, W.Va., Phone: 304-285-6302; boq9@cdc.gov, ASTM Staff Contact:, Timothy Brooke, Phone: 610-832-9729; tbrooke@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8698/Sept2010
-
A new ASTM standard will be useful to slide and engine companies, as well as makers of bushing materials, in studies that involve the measurement of system friction forces. The new standard, ASTM G203 , Guide for Determining Friction Energy Dissipation in Reciprocating Tribosystems, was developed by Subcommittee G02.50 on Friction, part of ASTM International Committee G02 on Wear and Erosion.…
-
A revision to an important ASTM nanotechnology standard incorporates a large-scale interlaboratory study that took place in 2008. The revised standard, ASTM E2490 , Guide for Measurement of Particle Size Distribution of Nanomaterials in Suspension by Photon Correlation Spectroscopy (PCS), is under the jurisdiction of Subcommittee E56.02 on Characterization: Physical, Chemical and Toxicological…
-
Honeycomb ceramics, porous with linear hollow channels, are being used worldwide in automotive catalytic converters and as diesel particulate filters for trucks. Flexural testing of this type of ceramics is addressed in a new ASTM International standard, ASTM C1674 , Test Method for Flexural Strength of Advanced Ceramics with Engineered Porosity (Honeycomb Cellular Channels) at Ambient…
-
A workshop on the role of standards in the emerging field of nanotechnology will be held Oct. 8-9, 2008, at the National Institute of Standards and Technology near Washington, D.C. The workshop, "Enabling Standards for Nanomaterial Characterization," is being co-sponsored by the National Cancer Institute's Nanotechnology Characterization Laboratory, the National Institute of Standards and…
-
The battle against cancer is being fought on many fronts. Among the most cutting-edge research efforts are attempts to engineer nanotechnology-based therapies. To aid in this endeavor, the Nanotechnology Characterization Laboratory, part of the National Cancer Institute’s Alliance for Nanotechnology in Cancer and the National Cancer Institute at Frederick, has developed methods for nanoparticle…, E2524, , Test Method for Analysis of Hemolytic Properties of Nanoparticles, -E2524 is a protocol for examining the destruction of red blood cells (hemolysis) that can lead to anemia, jaundice and other issues. All intravenously administered drugs must be examined to determine potential for hemolysis. • , E2525, , Test Method for Evaluation of the Effect of Nanoparticulate Materials on the Formation of Mouse Granulocyte-Macrophage Colonies, -E2525 describes a method for evaluating nanoparticle stimulation or inhibition of the maturation of certain bone marrow cells (macrophages). A common side effect of anti-cancer drugs is inhibition of this process, and bone marrow cells may be particularly sensitive to nano-scale material. • , E2526, , Test Method for Evaluation of Cytotoxicity of Nanoparticulate Materials on Porcine Kidney Cells and Human Hepatocarcinoma Cells, -Because studies have indicated that many nanoparticles are cleared from the body through the kidney or liver, these organs are good choices for target organ toxicity evaluation. E2526 presents a method for evaluation of nanomaterial toxicity by examining effects on kidney and cancerous liver cells. Martin Fritts is senior principal scientist at the Nanotechnology Characterization Laboratory and…
-
New Advanced Ceramics Standards from ASTM Cover Fracture Mirror Size Analysis, Tensile Strength DataSubcommittee C28.01 on Mechanical Properties and Performance, part of ASTM International Committee C28 on Advanced Ceramics, has recently approved two new standards, ASTM C1678 , Practice for Fractographic Analysis of Fracture Mirror Sizes in Ceramics and Glasses, and ASTM C1683 , Practice for Size Scaling of Tensile Strengths Using Weibull Statistics for Advanced Ceramics., ASTM C1678 —Bringing Consistency to Fracture Mirror Size Analysis, Fracture mirror size analysis is a powerful quantitative tool for the interpretation of broken ceramic and glass articles. While this type of analysis can be used to determine the stress in a part at the instant of fracture, inspection and interpretation procedures have often varied, resulting in uncertainty in stress estimates. ASTM C1678, Practice for Fractographic Analysis of Fracture Mirror…, ASTM C1683 —Scaling Strength Values, ASTM C1683, Practice for Size Scaling of Tensile Strength Using Weibull Statistics for Advanced Ceramics, provides methodology to convert fracture strength parameters estimated from data obtained with one test geometry to strength parameters representing other test geometries. Stephen Duffy, chair of civil engineering, Cleveland State University, and C28 member, says that companies producing…