Search
Advanced search
Filter by category
Filter by committee
Search results
-
ASTM International Committee E50 on Environmental Assessment, Risk Management and Corrective Action has issued the revised version of ASTM E1527 , Practice for Environmental Site Assessments: Phase I Environmental Site Assessment Process, under the jurisdiction of Subcommittee E50.02 on Real Estate Assessment and Management. ASTM E1527 describes the Phase I ESA process, a tool that is used to…, ASTM Committee E50 Next Meeting:, April 7-10, 2014, April Committee Week, Toronto, Ontario, Canada, Technical Contact:, Julie Kilgore, Wasatch Environmental Inc., Salt Lake City, Utah, Phone: 801-972-8400; jk@wasatch-environmental.com, ASTM Staff Contact:, Kathleen McClung, Phone: 610-832-9717; kmcclung@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9504
-
Standards development work for stormwater management and other related products will highlight the Dec. 10 meetings of ASTM International Committee C27 on Precast Concrete Products in Jacksonville, Fla., during the December 2013 ASTM Committee Week. Five proposed ASTM standards are under way for precast concrete stormwater management products: • WK26951, Practice for Field Measurement of…, ASTM Committee C27 Next Meeting:, Dec.10-11, 2013, December committee week, Jacksonville, Fla. ASTM Staff Contact: Joe Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9502
-
While machine-placed wet-cast precast concrete retaining wall units have been commercially available since the late 1990s, there has not been an ASTM standard available to cover these products. Now, ASTM International Committee C27 on Precast Concrete Products is working on such a standard. ASTM WK38192 , Specification for Wet-Cast Precast Modular Block Retaining Wall Units, is being developed by…, ASTM Committee C27 Next Meeting:, Dec. 10, 2013, December Committee Week, Jacksonville, Fla., Technical Contact:, Clint Hines, JC Hines and Associates LLC, Anderson, Ohio, Phone: 513-843-6570; clint@jchines.com, ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9441
-
Stormwater hydrodynamic systems are used to remove settable solids that could cause contamination from stormwater runoff. A proposed new ASTM International standard will be used to specify test material with a common target particle size distribution for use in testing HDS systems. The proposed new standard, ASTM WK39909 , Specification for Surrogate Test Solids for Measuring Performance of…, ASTM Committee C27 Next Meeting:, Dec. 10-11, 2013, December Committee Week, Jacksonville, Fla., Technical Contact:, Adam A. Stevens, CONTECH Engineered Solutions, Scarborough, Maine, Phone: 207-885-9740; stevensa@contech-cpi.com, ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9323
-
While there are many commercially available stormwater treatment products currently on the market, there is no universal testing standard that would allow the performance of these products to be accurately compared. A proposed new ASTM International standard will fill this need, providing a testing method for stormwater treatment products that use filtration as a primary treatment process. ASTM…
-
A proposed new ASTM International standard will improve the accuracy and usefulness of radiometry-related uncertainty estimates in a wide range of fast developing solar renewable energy applications, such as system performance and acceptance testing, resource assessment and solar energy system design engineering. The proposed standard, ASTM WK36479 , Practice for Uncertainty Evaluation of…
-
A watertight septic system ensures its integrity, and demonstrating that integrity is important because such systems have over time become more complex, expensive and critical to both system owners and to the environment. A new ASTM International standard fills a need for an in-field installation test for septic systems. The new standard, ASTM C1719 , Test Method for Installed Precast Concrete…, ASTM Committee C27 Next Meeting:, Dec. 6-7, 2011, December Committee Week, Tampa, Fla., Technical Contact:, Michael R. Miller, Press-Seal Gasket Corp., Fort Wayne, Ind., Phone: 260-918-1626; mmiler@press-seal.com, ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9008
-
Manufacturers of solar radiometers and testing laboratories for solar energy, materials and durability testing will be among the primary users of a new ASTM International standard that outlines procedures using indoor test methods to calibrate radiometers with dissimilar detectors. The new standard, ASTM G207 , Test Method for Indoor Transfer of Calibration from Reference to Field Pyranometers,…, ASTM Committee G03 Next Meeting:, Jan. 29-31, 2012, January Committee Week, Atlanta, Ga., Technical Contact:, Daryl Myers, National Renewable Energy Laboratory, Golden, Colo., Phone: 303-384-6768; daryl.myers@nrel.gov, ASTM Staff Contact:, Jeff Adkins, Phone: 610-832-9738; jadkins@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8965
-
A new ASTM International standard provides a more detailed and complete description of a test protocol that has been used for more than 40 years in code requirements and specifications for fire-retardant-treated wood. This test is now also used in some codes for building products that are not wood. The new standard, ASTM E2768 , Test Method for Extended Duration Surface Burning Characteristics of…
-
Continuing obligations are management procedures for property on which future use moves forward even though residual contamination may remain in the soil or groundwater. A new standard on addressing continuing obligations has now been approved by ASTM International Committee E50 on Environmental Assessment, Risk Management and Corrective Action . ASTM E2790 , Guide for Identifying and Complying…, ASTM Committee E50 Next Meeting:, Oct. 31-Nov. 3, October Committee Week, Tampa, Fla., Technical Contact:, J. Michael Sowinski Jr., Terradex, Carlsbad, Calif., Phone: 760-978-6120; mike@terradex.com, ASTM Staff Contact:, Daniel Smith, Phone: 610-832-9727; dsmith@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8927