Search
Advanced search
Filter by category
Filter by committee
Search results
-
Adopted in 2005, Chapter 7A of the California Building Code describes provisions for attic vents for new construction in wildfire-prone areas. While the California code notes that attic vents should resist the intrusion of embers and flames, there had not been a standard to evaluate such intrusion. A new standard, ASTM E2886/E2886M , Test Method for Evaluating the Ability of Exterior Vents to…, ASTM Committee E05 Next Meeting:, Dec. 8-11, 2014, December Committee, New Orleans, La., Technical Contact:, Stephen Quarles, Insurance Institute for Business and Home Safety, Richburg, S.C., Phone: 803-789-4209; squarles@ibhs.org , ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9617
-
A proposed new ASTM International standard is being developed for mounting plastic pipe and tube in the Steiner tunnel furnace. The draft procedure will help determine the fire-related properties of the pipe and tube in accordance with ASTM E84, Test Method for Surface Burning Characteristics of Building Materials. ASTM WK44535 , Practice for Mounting of Plastic Pipe, Plastic Tubing, Plastic Pipe…, ASTM Committee E05 Next Meeting:, June 23-26, 2014, June Committee, Toronto, Ontario, Canada, Technical Contact:, Joe Zicherman, Fire Cause Analysis, Berkeley, Calif., Phone: 510-649-1300; zicherman46@gmail.com, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9635
-
A wildland-urban interface is a transitional zone between unoccupied land and human development. There are currently more than 40 million homes located within WUI areas throughout the United States. A proposed new ASTM standard will be used to alleviate the issue of fire conditions that exist due to eaves and other projections in structures that exist in WUI areas. ASTM WK37414, Test Method for…, ASTM Committee E05 Next Meeting:, June 23-26, 2014, June Committee Week, Toronto, Ontario, Canada, Technical Contact:, John Simontacchi, Firefree Coatings Inc., San Rafael, Calif., Phone: 415-459-6488; jsimontacchi@firefree.com , ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9529
-
ASTM International recently developed its, Roadmap in Support of Commercial Nuclear Power, to provide a practical set of plans for updating ASTM nuclear energy standards in conjunction with the Nuclear Energy Standards Coordination Collaborative (NESCC). The ultimate goal of the roadmap, a document that spells out these plans in detail, is to ensure a safe and economical source of electricity for now and in the future. A link to the Roadmap can be found in the ASTM Nuclear Portal at…, Technical Contact:, Stephen Byrne, Phone: 860-342-7363; pnsbyrne@yahoo.com, ASTM Staff Contact:, Joe Koury, Phone: 610-832-9804; jkoury@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9321
-
Coated fabric products used for oil spill response procedures can deteriorate when stored for long periods of time. A proposed new ASTM standard will provide a nondestructive test for stored equipment to be evaluated for continued suitability over time. ASTM WK37298 , Test Method for Determining Storage Life of Coated Fabric Products, is being developed by Subcommittee F20.11 on Control , part of…, ASTM Committee F20 Next Meeting:, Oct. 23-24, 2012, October Committee Week, Atlanta, Ga., Technical Contact:, Peter Lane, Applied Fabric Technologies Inc., Applied Fabric Technologies Inc., Morris Skimmers International LLC, Orchard Park, N.Y., Phone: 716-662-0632; lane@afti.com, ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9310
-
ASTM International Committee F20 on Hazardous Substances and Oil Spill Response has approved several standards for in-situ burning. The latest proposed standard on this subject, ASTM WK37324 , Guide for Evaluation of In-Situ Burning Effectiveness, is currently being developed by Subcommittee F20.15 on In-Situ Burning . In-situ burning is a controlled burning, at the spill location, of oil that…, ASTM Committee F20 Next Meeting:, Oct. 23-24, 2012, October Committee Week, Atlanta, Ga., Technical Contact:, Steve Potter, SL Ross Environmental Research Ltd., Ottawa, Ontario, Canada, Phone: 613-232-1564; steve@slross.com, ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-932-9738; jadkins@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9294
-
A new test method is the latest in a series of ASTM International standards being developed to address the protection of exterior portions of structures during fires. The new standard, ASTM E2726/E2726M , Test Method for Evaluating the Fire-Test-Response of Deck Structures to Burning Brands, is being developed by Subcommittee E05.14 on External Fire Exposures , part of ASTM International…
-
New ASTM Nuclear Fuel Cycle Standard Provides Guidelines for Gathering Physical and Rheological DataObtaining data from the measurement and calculation of physical and rheological properties of radioactive solutions, slurries and sludges is essential in developing appropriate simulants for the design and testing of retrieval, transport, mixing and storage systems for treating radioactive materials. A new ASTM International standard provides guidelines for gathering this data. ASTM C1752 , Guide…
-
New Section of Website Collects ASTM Nuclear-Related Work in a Single Source ASTM International standards play an important role throughout the nuclear energy industry. In order to tie together the nuclear-related activity being conducted across its committees, ASTM has added a nuclear portal to its website ( www.astm.org ). The portal, which gathers together all of ASTM’s standards developing…
-
A new ASTM standard will provide the United States building codes with a test method designed to test a heating, ventilation and air conditioning duct system or its materials for fire resistance and other durability requirements. ASTM E2816 , Test Methods for Fire Resistive Metallic HVAC Duct Systems, was developed by Subcommittee E05.11 on Fire Resistance , under the jurisdiction of ASTM…