Search
Advanced search
Filter by category
Filter by committee
Search results
-
A new ASTM International standard will help medical device manufacturers collect sufficient data to demonstrate that they consistently clean medical devices to a safe and effective level. The new standard (soon to be published as F3127 , Guide for Validating Cleaning Lines for Medical Devices) is the result of a November 2011 symposium sponsored by ASTM on Cleaning Validation of Medical Devices.…, ASTM Committee F04 on Medical and Surgical Materials and Devices Next Meeting:, May 3-5, 2016, May Committee Week, Media Inquiries:, Dan Bergels, tel +1.610.832.9602; dbergels@astm.org, Technical Contact:, Randall J. Thoma, Ph.D., VeeSquared Consulting Services, Round Rock, Texas, tel +1.512.924.3832; randy.thoma@VeeSquared.com, ASTM Staff Contact:, Pat Picariello, tel +1.610.832.9720; ppicariello@astm.org Release #10050
-
, ASTM to Partner with ASC to Foster EPD Development, ASTM International will be collaborating with industry to develop Environmental Product Declarations (EPDs) across the 90+ industry markets they support, including sealants. The Adhesive and Sealant Council (ASC) will be partnering with ASTM International to raise awareness of this effort, educate industry on the value of Type III EPDs, and proactively engage industry in developing Product…, ASTM Staff Contact:, Tim Brooke, Phone: 610-832-9729; tbrooke@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9370
-
A proposed new ASTM International standard will provide an up-to-date method for the aluminum industry to analyze samples by inductively coupled plasma-atomic emission spectroscopy. The proposed new standard, WK35993 , Test Method for Analysis of Aluminum and Aluminum Alloys by Inductively Coupled Plasma Atomic Emission Spectrometry (Performance Based Method), is being developed by Subcommittee…
-
A new ASTM International standard will provide safety and risk management professionals with an aid in measuring the slip resistance of footwear in a wide variety of flooring situations. ASTM F2913 , Test Method for Measuring the Coefficient of Friction for Evaluation of Slip Performance of Footwear and Test Surfaces/Flooring Using a Whole Shoe Tester, is under the jurisdiction of Subcommittee…
-
Sealant manufacturers will use a new ASTM International standard to evaluate new products and changes to these products due to exposure to weather. The new standard, ASTM C1735 , Test Method for Measuring the Time Dependent Modulus of Sealants Using Stress Relaxation, is under the jurisdiction of Subcommittee C24.20 on General Test Methods , part of ASTM International Committee C24 on Building…, ASTM Committee C24 Next Meeting:, Jan. 8-10, 2012, Ft. Lauderdale, Fla., Technical Contact:, Christopher C. White, Ph.D., National Institute of Standards and Technology, Gaithersburg, Md., Phone: 301-975-6016; christopher.white@nist.gov, ASTM Staff Contact:, Stephen Mawn, Phone: 610-832-9726; smawn@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9005
-
ASTM International Committee F41 on Unmanned Maritime Vehicle Systems will meet on Aug. 17, 2011, at the Walter E. Washington Convention Center in Washington, D.C. The meeting will take place in conjunction with the AUVSI Unmanned Systems North American 2011 Conference. The F41 executive subcommittee meeting will begin at 7:00 a.m. on Aug. 17. in room 149A. In addition, all interested parties are…
-
Tribometers are used to assess the potential of humans to slip while walking on various surfaces. A new ASTM International test method will be used to provide a reference standard against which to validate and calibrate the performance of tribometers. ASTM F2508 , Practice for Validation and Calibration of Walkway Tribometers Using Reference Surfaces, has been developed by Subcommittee F13.10 on…
-
ASTM International Committee F13 on Pedestrian/Walkway Safety and Footwear is currently working on a proposed new standard for footwear designed for workers who do not necessarily need safety toe shoes but could use other protection such as puncture resistance, electrical shock protection and electrical grounding. The proposed new standard, ASTM WK27855 , Specification for Performance…
-
ASTM Committee E10 on Nuclear Technology and Applications has approved two new ASTM standards, ASTM E2628 , Practice for Dosimetry for Radiation Processing, and ASTM E2701 , Guide for Performance Characterization of Dosimeters and Dosimetry Systems for Use in Radiation Processing. Both standards are under the jurisdiction of Subcommittee E10.01 on Radiation Processing: Dosimetry and Applications…, ASTM Committee E10 Next Meeting:, Jan. 24-27, January committee week, San Antonio, Texas, Technical Contact:, (E2628) John Logar, Ethicon Inc., Somerville, N.J., Phone: 908-218-5638; jlogar8@its.jnj.com ; (E2701) Rod Chu, Ottawa, Ontario, Canada, Phone: 613-565-2305; rodchu@rogers.com, ASTM Staff Contact:, Joe Koury, Phone: 610-832-9804; jkoury@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #84 58/Jan2010
-
The use of rolling devices can provide a means to evaluate the adhesion of weather seals, for quality control in new installations, general evaluation of existing installations, and the investigation of water and air leakage through building enclosures. In order to better facilitate the use of rolling devices, ASTM International Committee C24 on Building Seals and Sealants is developing a…