Search
Advanced search
Filter by category
Filter by committee
Search results
-
A new ASTM International standard will help medical device manufacturers collect sufficient data to demonstrate that they consistently clean medical devices to a safe and effective level. The new standard (soon to be published as F3127 , Guide for Validating Cleaning Lines for Medical Devices) is the result of a November 2011 symposium sponsored by ASTM on Cleaning Validation of Medical Devices.…, ASTM Committee F04 on Medical and Surgical Materials and Devices Next Meeting:, May 3-5, 2016, May Committee Week, Media Inquiries:, Dan Bergels, tel +1.610.832.9602; dbergels@astm.org, Technical Contact:, Randall J. Thoma, Ph.D., VeeSquared Consulting Services, Round Rock, Texas, tel +1.512.924.3832; randy.thoma@VeeSquared.com, ASTM Staff Contact:, Pat Picariello, tel +1.610.832.9720; ppicariello@astm.org Release #10050
-
, ASTM to Partner with ASC to Foster EPD Development, ASTM International will be collaborating with industry to develop Environmental Product Declarations (EPDs) across the 90+ industry markets they support, including sealants. The Adhesive and Sealant Council (ASC) will be partnering with ASTM International to raise awareness of this effort, educate industry on the value of Type III EPDs, and proactively engage industry in developing Product…, ASTM Staff Contact:, Tim Brooke, Phone: 610-832-9729; tbrooke@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9370
-
A continuing interest among road authorities to improve highway safety has led to efforts to improve wet-night visibility of pavement markings, including a new ASTM International standard. ASTM E2832 , Test Method for Measuring the Coefficient of Retroreflected Luminance of Pavement Markings in a Standard Condition of Continuous Wetting (RL-2), was developed by Subcommittee E12.10 on…, ASTM Committee E12 Next Meeting:, Jan. 30-31, 2013, January committee week, Jacksonville, Fla., Technical Contact:, Paul Carlson, Texas Transportation Institute, College Station, Texas, Phone: 979-845-6004; paul-carlson@tamu.edu, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9243
-
A new ASTM International standard will provide safety and risk management professionals with an aid in measuring the slip resistance of footwear in a wide variety of flooring situations. ASTM F2913 , Test Method for Measuring the Coefficient of Friction for Evaluation of Slip Performance of Footwear and Test Surfaces/Flooring Using a Whole Shoe Tester, is under the jurisdiction of Subcommittee…
-
Sealant manufacturers will use a new ASTM International standard to evaluate new products and changes to these products due to exposure to weather. The new standard, ASTM C1735 , Test Method for Measuring the Time Dependent Modulus of Sealants Using Stress Relaxation, is under the jurisdiction of Subcommittee C24.20 on General Test Methods , part of ASTM International Committee C24 on Building…, ASTM Committee C24 Next Meeting:, Jan. 8-10, 2012, Ft. Lauderdale, Fla., Technical Contact:, Christopher C. White, Ph.D., National Institute of Standards and Technology, Gaithersburg, Md., Phone: 301-975-6016; christopher.white@nist.gov, ASTM Staff Contact:, Stephen Mawn, Phone: 610-832-9726; smawn@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9005
-
Tribometers are used to assess the potential of humans to slip while walking on various surfaces. A new ASTM International test method will be used to provide a reference standard against which to validate and calibrate the performance of tribometers. ASTM F2508 , Practice for Validation and Calibration of Walkway Tribometers Using Reference Surfaces, has been developed by Subcommittee F13.10 on…
-
ASTM International Committee F13 on Pedestrian/Walkway Safety and Footwear is currently working on a proposed new standard for footwear designed for workers who do not necessarily need safety toe shoes but could use other protection such as puncture resistance, electrical shock protection and electrical grounding. The proposed new standard, ASTM WK27855 , Specification for Performance…
-
During a virtual meeting on Oct. 28, Committee D32 held an ”open house” for potential new members. The open house featured an introduction to ASTM, an explanation of Committee D32’s mission, and highlights of the committee’s active task groups. A recording of this webinar can be viewed on Committee D32’s Web site. Founded in 1975, ASTM Committee D32 develops test methods, classifications,…
-
The use of rolling devices can provide a means to evaluate the adhesion of weather seals, for quality control in new installations, general evaluation of existing installations, and the investigation of water and air leakage through building enclosures. In order to better facilitate the use of rolling devices, ASTM International Committee C24 on Building Seals and Sealants is developing a…
-
A request from the United States Navy was the impetus behind the development of a new ASTM International standard, E2630 , Test Method for Luminance Ratio of a Fluorescent Specimen Using a Narrow Band Source. The new standard was developed by Subcommittee E12.05 on Fluorescence, part of ASTM International Committee E12 on Color and Appearance. Richard Harold, consultant, Color and Appearance…