Search
Advanced search
Filter by category
Filter by committee
Search results
-
A proposed new ASTM standard will help determine the longevity of in-service building sealants. The proposed guide ( WK48490 , Practice for Developing Accelerated Tests to Aid Prediction of the Design Life of Sealants) provides steps that should be followed in creating accelerated tests for these products that provide insulation, prevent leaking, and more. “This standard is a reflection of the…, ASTM Committee C24 on Building Seals and Sealants Next Meeting:, June 26-28, 2016, June Committee Week, Chicago, Ill., Media Inquiries:, Dan Bergels, tel +1.610.832.9602; dbergels@astm.org, Technical Contact:, Christopher C. White, Ph.D., MBA, National Institute of Standards and Technology, Gaithersburg, Md., tel +1.301.975.6016; Christopher.white@nist.gov, ASTM Staff Contact:, Stephen Mawn, tel +1.610.832.9726; smawn@astm.org Release #10089
-
A proposed ASTM International standard will help both designers and consumers choose the best aerosol foam sealants for their projects. The proposed guide, being developed by ASTM’s Committee C24 on Building Seals and Sealants , will overview the differences among the three main types of sealants and their applications: • window, door and skylights (usually in a secondary seal application…, ASTM Committee C24 on Building Seals and Sealants Next Meeting:, June 26-28, 2016, June Committee Week, Chicago, Ill., Media Inquiries:, Dan Bergels, tel +1.610.832.9602; dbergels@astm.org, Technical Contact:, Steve Duren, Adhesive and Sealant Council Inc., tel +1.952.300.8280; steve.duren@ascouncil.org, ASTM Staff Contact:, Stephen Mawn, tel +1.610.832.9726; smawn@astm.org Release #10088
-
A new ASTM International standard will help medical device manufacturers collect sufficient data to demonstrate that they consistently clean medical devices to a safe and effective level. The new standard (soon to be published as F3127 , Guide for Validating Cleaning Lines for Medical Devices) is the result of a November 2011 symposium sponsored by ASTM on Cleaning Validation of Medical Devices.…, ASTM Committee F04 on Medical and Surgical Materials and Devices Next Meeting:, May 3-5, 2016, May Committee Week, Media Inquiries:, Dan Bergels, tel +1.610.832.9602; dbergels@astm.org, Technical Contact:, Randall J. Thoma, Ph.D., VeeSquared Consulting Services, Round Rock, Texas, tel +1.512.924.3832; randy.thoma@VeeSquared.com, ASTM Staff Contact:, Pat Picariello, tel +1.610.832.9720; ppicariello@astm.org Release #10050
-
Activated carbon is processed to have small, low-volume pores that increase the surface area available for adsorption. It has applications in the medical, environmental and energy realms, among others. Since 1962, ASTM International Committee D28 on Activated Carbon has developed standards that play a pre-eminent role in how activated carbon is used. A D28 subcommittee, D28.02 on Liquid Phase…, WK47401, Xylenol Orange Dye, The xylenol orange dye test is a way to determine the relative adsorption rate of unused or reactivated carbons by adsorption of xylenol orange from aqueous solution. This is an important means for deciding which type of activated carbon to use to a specific water treatment application. “Activated carbon performance can roughly be defined as a combination of the ability to adsorb a particular…, WK47421, Particle Size Distribution, Mercury flue gas, home water filters and potable water treatment are the main applications in which powdered and fine mesh carbons are used. A proposed new test method will describe how a laser light scattering technique can determine the particle size distribution of fine mesh activated carbon. ASTM member Neal Megonnell, vice president, sales and marketing, Haycarb USA, says the proposed test…, ASTM Committee D28 Next Meeting:, April 27, April Committee Week, Anaheim, Calif., Technical Contact:, (WK47401) Adam Redding, Ph.D., Evoqua Water Technologies LLC, Northwest, Pa., tel +1.724.719.0805; adam.redding@evoqua.com and (WK47421) Neal E. Megonnell, Haycarb USA, Pittsburgh, Pa., tel +1.412.709.7487; neal@haycarbusa.com, ASTM Staff Contact:, Kelly Paul, tel +1.610.832.9745; kpaul@astm.org, ASTM PR Contact:, Barbara Schindler, tel +1.610.832.9603; bschindl@astm.org Release #9731
-
A new ASTM International standard will be used to provide a uniform international method for recording occupational injuries and illnesses, in order to make global performance comparisons of companies in keeping workers safe. ASTM E2920 , Guide for Recording Occupational Injuries and Illnesses, was developed by Subcommittee E34.80 on Industrial Health , part of ASTM International Committee E34 on…, ASTM Committee E34 Next Meeting:, Oct. 8-9, 2014, October Committee Week, New Orleans, La., Technical Contacts:, Thomas J. Slavin, Cardno ChemRisk, Chicago, Ill., Phone: 312-863-2350; tom.slavin@cardno.com; and Steve Newell, ORCHSE Strategies LLC, Washington, D.C., Phone: 202-510-0513; steve.newell@hseorc.com , ASTM Staff Contact:, Kevin Shanahan, Phone: 610-832-9737; kshanahan@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9605
-
, ASTM to Partner with ASC to Foster EPD Development, ASTM International will be collaborating with industry to develop Environmental Product Declarations (EPDs) across the 90+ industry markets they support, including sealants. The Adhesive and Sealant Council (ASC) will be partnering with ASTM International to raise awareness of this effort, educate industry on the value of Type III EPDs, and proactively engage industry in developing Product…, ASTM Staff Contact:, Tim Brooke, Phone: 610-832-9729; tbrooke@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9370
-
Accidents involving the handling of annealed glass have heightened interest in standards that could improve safety in the glass industry. In response, ASTM International Committee E34 on Occupational Health and Safety has approved a new standard, ASTM E2875/E2875M , Guide for Personal Protective Equipment for the Handling of Flat Glass. The new standard was developed by Subcommittee E34.35 on…, ASTM Committee E34 Next Meeting:, Oct. 24-25, 2012, October committee week, Atlanta, Ga., Technical Contact:, Michael Marsala, Guardian Industries Corp., Auburn Hills, Mich., Phone: 248-340-2322; mmarsala@guardian.com, ASTM Staff Contact:, Kevin Shanahan, Phone: 610-832-9737; kshanahan@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9257
-
Sealant manufacturers will use a new ASTM International standard to evaluate new products and changes to these products due to exposure to weather. The new standard, ASTM C1735 , Test Method for Measuring the Time Dependent Modulus of Sealants Using Stress Relaxation, is under the jurisdiction of Subcommittee C24.20 on General Test Methods , part of ASTM International Committee C24 on Building…, ASTM Committee C24 Next Meeting:, Jan. 8-10, 2012, Ft. Lauderdale, Fla., Technical Contact:, Christopher C. White, Ph.D., National Institute of Standards and Technology, Gaithersburg, Md., Phone: 301-975-6016; christopher.white@nist.gov, ASTM Staff Contact:, Stephen Mawn, Phone: 610-832-9726; smawn@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9005
-
A new ASTM International subcommittee has been created to develop standards that will be meaningful and accurate performance indicators to measure work-related injury and illness performance throughout the world. Subcommittee E34.55 on Occupational Safety and Health Performance Improvement is under the jurisdiction of ASTM International Committee E34 on Occupational Health and Safety. “Measuring…
-
A proposed new standard being developed by ASTM International Committee F30 on Emergency Medical Services will be useful to medical equipment manufacturers, certification agencies and care providers, with patients being the ultimate beneficiaries. The proposed new standard, ASTM WK27973 , Specification for Environmental Performance of Medical Equipment for Use on Fixed and Rotary-Wing Aircraft,…, Technical Contact:, Pete Chambers, Marketing Assessment Inc., Phone: 703-673-9003; pete@marketingassessment.com, ASTM Staff Contact:, Scott Orthey, Phone: 610-832-9730; sorthey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8671/Sept2010