Search
Advanced search
Filter by category
Filter by committee
Search results
-
A new ASTM International standard will help medical device manufacturers collect sufficient data to demonstrate that they consistently clean medical devices to a safe and effective level. The new standard (soon to be published as F3127 , Guide for Validating Cleaning Lines for Medical Devices) is the result of a November 2011 symposium sponsored by ASTM on Cleaning Validation of Medical Devices.…, ASTM Committee F04 on Medical and Surgical Materials and Devices Next Meeting:, May 3-5, 2016, May Committee Week, Media Inquiries:, Dan Bergels, tel +1.610.832.9602; dbergels@astm.org, Technical Contact:, Randall J. Thoma, Ph.D., VeeSquared Consulting Services, Round Rock, Texas, tel +1.512.924.3832; randy.thoma@VeeSquared.com, ASTM Staff Contact:, Pat Picariello, tel +1.610.832.9720; ppicariello@astm.org Release #10050
-
A proposed ASTM standard will meet the need for a method that labs can follow when testing samples for mold. The proposed standard (WK17177, Test Method for Examination of Fungal Structures on Tape Lift Samples by Optical Microscopy) will provide labs with an approach based on quality and science. The primary users of the standard will be labs that provide services in the fields of occupational…, Committee D22 on Air Quality Next Meeting:, April 26-May 1, 2015, April committee week, Anaheim, Calif., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Terri L. Williams, Wisconsin Occupational Health Laboratory, University of Wisconsin, Madison, Wis., tel +1.608.224.6261; terri.williams@slh.wisc.edu, ASTM Staff Contact:, Jeffrey Adkins, tel +1.610.832.9738; jadkins@astm.org Release # 9797 March 17, 2015 ###
-
Taking a tape-lift sample is one of the main practices used by indoor environmental quality investigators for detecting whether mold structures (for example, spores and hyphae) have either settled onto or colonized the surface. Despite the popularity of the method, there can be significant inconsistency in how tape lifts are collected. A new ASTM standard, ASTM D7910 , Practice for the Collection…, ASTM Committee D22 Next Meeting:, Oct. 5-8, 2014, October Committee Week, New Orleans, La., Technical Contact:, John M. Neville, Ph.D., Bureau Veritas North America Inc., Novi, Mich., Phone: 248-344-3042; john.neville@us.bureauveritas.com, ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9655
-
A new standard, ASTM D7886 , Practice for Asbestos Exposure Assessments for Repetitive Maintenance and Installation Tasks, will aid those testing asbestos exposures by quantifying such exposure levels. Regulations set forth by the U.S. Occupational Safety and Health Administration require that worker exposure to asbestos be determined with a “high level of certainty.” “ASTM D7886 overcomes the…, ASTM Committee D22 Next Meeting:, Oct. 5-8, 2014, October Committee Week, New Orleans, La., Technical Contact:, Andrew F. Oberta, MPS, CIH, The Environmental Consultancy, Austin, Texas, Phone: 512-266-1368; andyobe@aol.com , ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9639
-
Gaseous hydrogen fluoride is a harsh respiratory irritant; the inhalation of hydrofluoric acid mists causes severe lung damage in exposed workers. A proposed new ASTM standard, WK38734 , Test Method for the Determination of Particulate Fluorides and Hydrofluoric Acid Using Filter Sampling and Suppressed Ion Chromatography, will be used to prevent overexposure of hydrofluoric acid/hydrogen…, ASTM Committee D22 Next Meeting:, Oct. 5-8, 2014, October Committee Week, New Orleans, La., Technical Contact:, Dietmar Breuer, IFA, Sankt Augustin, Germany, Phone: +49 (0) 2241 231-2533; dietmar.breuer@dguv.de , ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9585
-
While monitoring air quality is important in many situations, a variety of different quantitative passive samplers are available for such work. A proposed new ASTM standard, ASTM WK45755 , Guide for Selection of Quantitative Passive Samplers for Volatile Organic Compounds in Air, will help users decide which air sampler type will best suit their needs. ASTM WK45755 will cover issues such as the…, ASTM Committee D22 Next Meeting:, Oct. 5-8, 2014, October Committee Week, New Orleans, La., Technical Contact:, Nicola Watson, Markes International, Loveland, Ohio, Phone: 513-488-6161; nwatson@markes.com , ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9578
-
The laboratory conditions test described in a new ASTM International standard will be used by manufacturers to determine the sustained air performance and exhaust emissions of a central vacuum cleaner. ASTM F2826 , Test Method for Evaluating the Sustained Air Performance and Exhaust Emissions of Central Vacuum Cleaning Units, was developed by Subcommittee F11.22 on Air Performance , part of ASTM…, ASTM Committee F11 Next Meeting:, May 5-7, 2014, May Committee Week, Toronto, Ontario, Canada, Technical Contact:, Darrell Nieschwitz, H-P Products Inc., Louisville, Ohio, Phone: 330-875-5556, ext. 2272; dnieschwitz@h-pproducts.com, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9584
-
A proposed new ASTM International standard will provide a laboratory conditions test for determining the sustained air performance and exhaust emissions of central vacuum cleaners. ASTM WK14392 , Test Method for Evaluating the Sustained Air Performance and Exhaust Emissions of Central Vacuum Cleaning Units, is being developed by Subcommittee F11.22 on Air Performance , part of ASTM International…, ASTM Committee F11 Next Meeting:, May 5-7, 2014, May Committee Week, Toronto, Ontario, Canada, Technical Contact, : Darrell Nieschwitz, H-P Products Inc., Louisville, Ohio, Phone: 330-875-5556, ext. 2272; dnieschwitz@h-pproducts.com, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9532
-
, ASTM to Partner with ASC to Foster EPD Development, ASTM International will be collaborating with industry to develop Environmental Product Declarations (EPDs) across the 90+ industry markets they support, including sealants. The Adhesive and Sealant Council (ASC) will be partnering with ASTM International to raise awareness of this effort, educate industry on the value of Type III EPDs, and proactively engage industry in developing Product…, ASTM Staff Contact:, Tim Brooke, Phone: 610-832-9729; tbrooke@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9370
-
ASTM International Committee F11 on Vacuum Cleaners has formed a new task group to develop proposed standards for high efficiency particulate air filtration, typically known as HEPA. The task group, part of Subcommittee F11.23 on Filtration, will develop standards to clarify methodology and criteria used to define HEPA filtration for sealed vacuum cleaner systems and filter components used in…, ASTM Committee F11 Next Meeting:, May 20-22, 2013, May Committee Week, Indianapolis, Ind., Technical Contact:, Zoe Wilson, Bissell Homecare Inc., Grand Rapids, Mich., Phone: 616-735-5142; zoe.wilson@bissell.com , ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9338