The need for a consensus standard targeting the measurement of gaseous hydrocarbons and other components of gaseous streams allowing users to better comply with U.S. Environmental Protection Agency’s greenhouse gas regulation provided the impetus for the development of a proposed new ASTM International standard meeting this need. ASTM WK33788 , Test Method for Determination of Hydrocarbons and…
-
Rheologists are encouraged to join in the development of a proposed new practice that will help standardize calibration of rotational rheometers to obtain accurate normal force measurements. ASTM WK33687 , Practice for Normal Force Calibration for Rotational Rheometers, is being developed by Subcommittee E37.08 on Rheology , part of ASTM International Committee E37 on Thermal Measurements . The…, ASTM Committee E37 Next Meeting:, Aug. 10-11, in conjunction with the North American Thermal Analysis Society Annual Conference, Des Moines, Iowa, Technical Contact:, Kenneth Aniunioh, Shimadzu Scientific Instruments, Laurel, Md., Phone: 864-633-7690; kenebaano@yahoo.com, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8923
-
ASTM International Committee D03 on Gaseous Fuels recently approved two new standards for the hydrogen fuel industry: ASTM D7650 , Test Method for Sampling of Particulate Matter in High Pressure Hydrogen Used as a Gaseous Fuel with an In-Stream Filter, and ASTM D7651 , Test Method for Gravimetric Measurement of Particulate Concentration of Hydrogen Fuel. Subcommittee D03.14 on Hydrogen and Fuel…
-
ASTM International Committee D03 on Gaseous Fuels invites all interested parties to participate in their standards developing activities. Proposed new standards currently being developed by subcommittees within D03 include ASTM WK24874, Test Method for the Determination of Moisture Vapor Concentration in Natural Gas and by Tunable Diode Laser Spectroscopy (TDLAS), and ASTM WK24875 , Practice for…, Tunable Diode Laser Spectroscopy, The proposed new standard, ASTM WK24874 , is being developed at the request of several gas companies that use TDLAS analyzers for the measurement of moisture in natural gas. While TDLAS has become a popular type of gas analysis, no specific standard currently exists for its use. ASTM WK24874 is under the jurisdiction of Subcommittee D03.12 on On-Line/At-Line Analysis of Gaseous Fuels. According…, Siloxanes, While biofuel from landfills and sewage digestion has been used as fuel for local gas turbine engines, it is necessary to hold the content of siloxanes within the fuel down to 50 parts per billion. Siloxanes that can coat the turbine under working conditions are converted to an abrasive silicone dioxide coating that greatly reduces the lifetime of the engine. ASTM WK24875 is currently being…
-
The ASTM International Proficiency Testing Center is pleased to offer a 2010 Proficiency Testing Program on Thermal Analyses of Plastics (TAP) to laboratories who need a statistical quality assurance tool that will enable them to improve and maintain a high level of performance in conducting ASTM Differential Scanning Calorimetry (DSC), Oxidative-Induction Time (OIT) by Differential Scanning…, ASTM D3418, , Standard Test Method for Transition Temperatures and Enthalpies of Fusion and Crystallization of Polymers by Differential Scanning Calorimetry (DSC);, ASTM D3850, , Standard Test Method for Rapid Thermal Degradation of Solid Electrical Insulating Materials By Thermogravimetric Method (TGA); and, ASTM D3895, , Standard Test Method for Oxidative-Induction Time of Polyolefins by Differential Scanning Calorimetry. For each test trial, laboratory participants receive two sample materials along with interactive electronic data report forms and test instructions. Using the specified ASTM program tests, participating laboratories conduct the tests of their choice that they routinely run. Upon completion of…
-
Sulfur compounds are known for their smell, but odor isn’t the only issue sulfur compounds create, at least when found in various kinds of gas. Too much sulfur in gaseous fuels, such as natural gas, petroleum gases and biogases, can be corrosive to equipment, result in regulatory issues, and can inhibit or destroy catalysts used in gas processing and utilization equipment. However, sulfur gases…
-
A new ASTM International standard will have applications in a variety of factories, on artificial turfs and playing surfaces, and even in the classroom. The new standard, G194 , Test Method for Measuring Rolling Friction Characteristics of a Spherical Shape on a Flat Horizontal Surface, was developed by Subcommittee G02.50 on Friction, part of ASTM International Committee G02 on Wear and Erosion…
-
The use of rolling devices can provide a means to evaluate the adhesion of weather seals, for quality control in new installations, general evaluation of existing installations, and the investigation of water and air leakage through building enclosures. In order to better facilitate the use of rolling devices, ASTM International Committee C24 on Building Seals and Sealants is developing a…
-
Testing the oxygen permeation of packaging material is important for the suppliers of various barrier materials, as well as users of these materials in the food, pharmaceutical and consumer product companies, universities, research organizations and other industries. This kind of testing is covered in a new ASTM International standard approved by Committee F02 on Flexible Barrier Packaging, F2622…
-
Sterilized medical devices are indispensable to doctors and surgeons around the world. Peel pouches, otherwise known as preformed sterile barrier systems, are used to keep these devices sterile during all physical handling. These pouches can be made with a wide variety of material and are produced by many different suppliers, but the trait all pouches must share is the ability to protect devices…