Since 2009, the National Fire Protection Association has required arc rated gloves in its NFPA70E, Standard for Electrical Safety in the Workplace. A new ASTM standard will now provide arc rating thermal protective values for gloves, which will allow more gloves to be used inside an arc flash zone when there is no shock hazard. The new standard, ASTM F2675/F2675M , Test Method for Determining Arc…, ASTM Committee F18 Next Meeting:, Oct. 20-23, 2013, Charleston, S.C., Technical Contact:, Hugh Hoagland, ArcWear, Louisville, Ky., Phone: 502-832-9737; hugh@arcwear.com , ASTM Staff Contact:, Kevin Shanahan, Phone: 610-832-9737, kshanahan@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9469
-
A newly revised ASTM terminology standard reflects the latest technological advances in particle size analysis (standard test sieves) and particle separation (screening media). ASTM E1638 , Terminology Relating to Sieves, Sieving Methods and Screening Media, was developed by Subcommittee E29.01 on Sieves, Sieving Methods and Screening Media , part of ASTM International Committee E29 on Particle…, ASTM Committee E29 Next Meeting:, May 1-2, 2013, in conjunction with B09 May meeting, Ft. Lauderdale Beach, Fla., Technical Contact:, Kenneth H. Beyer, American Wire Cloth Institute, Elizabeth, N.J., Phone: 908-688-4600; ken@uniquewire.com, ASTM Staff Contact:, Katerina Koperna, Phone: 610-832-9728; kkoperna@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9290
-
A proposed new standard being developed by ASTM International Committee F18 on Electrical Protective Equipment for Workers will provide guidance to assist in the required testing of live-line tools. ASTM WK33590 , Guide for In-Service Inspection, Maintenance and Electrical Testing of Insulating Tools (Fiberglass-Reinforced Plastic (FPR) and Wooden Live-Line Tools), is under the jurisdiction of…
-
A new ASTM International standard covers a special grade of industrial woven wire cloth called filter cloth for general filtration, including the separation of solids from fluids. ASTM E2814 , Guide for Industrial Woven Wire Filter Cloth, was developed by Subcommittee E29.01 on Sieves, Sieving Methods and Screening Media , part of ASTM International Committee E29 on Particle and Spray…, ASTM Committee E29 Next Meeting:, Oct. 31-Nov. 1, 2011, October Committee Week, Tampa, Fla., Technical Contact:, Ken Beyer, Unique Wire Weaving Co., Hillside, N.J., Phone: 908-688-4600; ken@uniquewire.com, ASTM Staff Contact:, Christine Sierk, Phone: 610-832-9728; csierk@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8934
-
Discussions concerning how easily test results for dimension stone test specimens can be influenced by improper or nonuniform preparation methods have led to the ongoing development of a proposed new ASTM International standard. The new standard, ASTM WK31179 , Practice for Selection and Preparation of Dimension Stone Test Specimens, is being developed by Subcommittee C18.08 on Selection of…
-
The
-
Petrography is routinely performed on dimension stone for many construction projects in which new stone is being used, and it is often required in technical specifications. In order to facilitate this process, ASTM International Committee C18 on Dimension Stone has developed a new standard, ASTM C1721 , Guide for Petrographic Examination of Dimension Stone. The new standard is under the…, ASTM Committee C18 Next Meeting:, April 21-22, April Committee Week, St. Louis, Mo., Technical Contact:, Michael Scheffler, Wiss, Janney, Elstner Associates Inc., Northbrook, Ill., Phone: 847-272-7400; mscheffler@wje.com, ASTM Staff Contact:, Jeff Adkins, Phone: 610-832-9738; jadkins@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8432/Dec2009
-
ASTM International Committee E29 on Particle and Spray Characterization has recently approved an extensive revision of ASTM standard E11 , Specification for Wire Cloth and Sieves for Testing Purposes. The revision will lead to better control of the quality of sieve cloths and test sieves. ASTM E11 is under the jurisdiction of Subcommittee E29.01 on Sieves, Sieving Methods and Screening Media.…
-
Arc protective blankets are used in many electrical applications to protect workers who are stationed near energized electrical parts. While these blankets have been used for years, there have been no testing criteria for their evaluation. A new ASTM International standard will be used to determine the effectiveness of arc protective blankets in suppressing the combined effect of an arc flash and…
-
A new ASTM International standard, F 2621 , Practice for Determining Response Characteristics and Design Integrity of Arc Related Finished Products in an Electric Arc Exposure, is the latest in a series of standards developed by Subcommittee F18.65 on Wearing Apparel to reduce the number of fatalities and injuries caused by electric arcs. ASTM Practice F 2621 provides procedural guidelines for…