Non-destructive moisture meters are now widely used in determining moisture levels in concrete, gypsum concrete and other types of floor slabs. A new ASTM International standard qualifies the types of meter suitable for this purpose and provides guidelines for how, where and when such moisture meters are used and what limitations exist. The new standard, ASTM F2659 , Guide for Preliminary…, ASTM Committee F06 Next Meeting:, Nov. 10-11, New Orleans, La., Technical Contact:, Sean Fallon, Dublin, Ireland, Phone: +011-353-1-285-1861; seanfallon@ireland.com, ASTM Staff Contact:, Stephen Mawn, Phone: 610-832-9726; smawn@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #870/Oct2010
-
Zirconium is used as an anti-corrosive finishing/surface treatment on metal substrates. If the coating of zirconium is too thin, then the sought-for metal property will not be achieved. Similarly, applying too thick a coat means that treatment material is wasted and so is money. Therefore, ASTM International Committee D01 on Paint and Related Coatings, Materials and Applications has developed a…, ASTM Committee D01 Next Meeting:, Jan. 30-Feb. 1, 2011, January Committee Week, Baltimore, Md., Technical Contact:, Christelle Petiot, Oxford Instruments Analytical, High Wycombe, Buckinghamshire, United Kingdom; christelle.petiot@oxinst.com, ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8685/Sept2010
-
An effort currently under way by the U.S. Federal Highway Administration to set national standards for minimum maintained retroreflectivity levels for pavement markings has illustrated the need for a practical protocol to measure such levels. In response to this need, ASTM International Committee D04 on Road and Paving has developed ASTM D7585/D7585M , Practice for Evaluating Retroreflective…
-
ASTM International Committee D01 on Paint and Related Coatings, Materials and Applications has approved a standard covering a test chamber used by transportation departments and similar agencies throughout the world to specify and test the dry speed of waterborne pavement marking paints at elevated relative humidity. The new standard, ASTM D7539 , Practice for Using a Test Chamber for Humidity…, ASTM Committee D01 Next Meeting:, Jan. 30-Feb 1, 2011, January Committee Week, Baltimore, Md., Technical Contact:, Donald Schall, Dow Chemical Co., Spring House, Pa., Phone: 215-641-7163; dschall@dow.com, ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8675/Sept2010
-
Safety concerns and the need to obtain representative samples are the driving forces behind a proposed new standard being developed by ASTM International Committee D04 on Road and Paving Materials. The proposed new standard, ASTM WK26774 , Practice for Sampling Bituminous Paving Material from a Truck by Means of a Mechanical Sampling Device, is under the jurisdiction of Subcommittee D04.30 on…, ASTM Committee D04 Next Meeting:, Dec. 7-9, December Committee Week, New Orleans, La., Technical Contact:, Brian Johnson, AASHTO Materials Reference Laboratory, Gaithersburg, Md.; Phone: 301-975-6423; bjohnson@amrl.net, ASTM Staff Contact:, Daniel Smith, Phone: 610-832-9727; dsmith@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8612
-
The
-
The need for a standard test method that would allow the determination of the complex shear modulus of bituminous mixtures using relatively inexpensive laboratory equipment has led to the development of a new ASTM International standard, ASTM D7552 , Test Method for Determining the Complex Shear Modulus (G*) of Bituminous Mixtures Using Dynamic Shear Rheometer. According to Gerald Reinke,…, ASTM Committee D04 Next Meeting:, June 8-10, June committee week, St. Louis, Mo. Technical Contact: Gerald Reinke, MTE Services Inc., Phone: 608-779-6304; greinke@mathy.com ASTM Staff Contact: Daniel Smith, Phone: 610-832-9727; dsmith@astm.org ASTM PR Contact: Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8457/Jan2010
-
Petrography is routinely performed on dimension stone for many construction projects in which new stone is being used, and it is often required in technical specifications. In order to facilitate this process, ASTM International Committee C18 on Dimension Stone has developed a new standard, ASTM C1721 , Guide for Petrographic Examination of Dimension Stone. The new standard is under the…, ASTM Committee C18 Next Meeting:, April 21-22, April Committee Week, St. Louis, Mo., Technical Contact:, Michael Scheffler, Wiss, Janney, Elstner Associates Inc., Northbrook, Ill., Phone: 847-272-7400; mscheffler@wje.com, ASTM Staff Contact:, Jeff Adkins, Phone: 610-832-9738; jadkins@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8432/Dec2009
-
Special considerations need to be made for flooring in multi-purpose rooms, particularly those in child care buildings, elementary schools and long-term care facilities. ASTM International Committee F06 on Resilient Floor Coverings is currently developing a proposed new standard for such flooring. WK24836 , Specification for Active Area, Multipurpose Flooring, is under the jurisdiction of…
-
More frequent worldwide use of asphalt-rubber binders in road building has increased the need for rotational viscotesters, which are used to ensure proper quality control and assurance. While an appropriate standard for viscotesters does not currently exist, a proposed new ASTM standard will answer this need. The proposed standard, WK25108 , Test Method for Measurement of Apparent Viscosity of…