Search
Advanced search
Filter by category
Filter by committee
Search results
-
Sealant manufacturers will use a new ASTM International standard to evaluate new products and changes to these products due to exposure to weather. The new standard, ASTM C1735 , Test Method for Measuring the Time Dependent Modulus of Sealants Using Stress Relaxation, is under the jurisdiction of Subcommittee C24.20 on General Test Methods , part of ASTM International Committee C24 on Building…, ASTM Committee C24 Next Meeting:, Jan. 8-10, 2012, Ft. Lauderdale, Fla., Technical Contact:, Christopher C. White, Ph.D., National Institute of Standards and Technology, Gaithersburg, Md., Phone: 301-975-6016; christopher.white@nist.gov, ASTM Staff Contact:, Stephen Mawn, Phone: 610-832-9726; smawn@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9005
-
Discovering how differences between two versions of a product will affect that product’s performance continues to be a challenge for sensory professionals. However, in the past 30 years, the testing method known as the Tetrad test has begun to emerge as a means of saving companies money by enabling more information to be extracted from smaller product tests. ASTM International Committee E18 on…, ASTM Committee E18 Next Meeting:, Nov. 1-4, 2011, October Committee Week, Tampa, Fla., Technical Contact:, John M. Ennis, The Institute for Perception, Richmond, Va., Phone: 804-675-2980; john.m.ennis@ifpress.com, ASTM Staff Contact:, Scott Orthey, Phone: 610-832-9730; sorthey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8898
-
Laboratories that have the ability to analyze titanium and titanium alloys by spark-atomic emission spectrometry or glow discharge-AES are currently being sought to participate in an interlaboratory study for a proposed new standard. ASTM WK25738 , Test Method for Analysis of Titanium and Titanium Alloys by Spark-Atomic Emission/Glow Discharge-Atomic Emission Spectrometry, is currently being…, ASTM Committee E01 Next Meeting:, May 15-18, 2011, May Committee Week, Anaheim, Calif., Technical Contact:, Kevin VonScio, Perryman Co., Houston, Pa., Phone: 724-746-9390; kvonscio@perrymanco.com, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8855
-
Discussions concerning how easily test results for dimension stone test specimens can be influenced by improper or nonuniform preparation methods have led to the ongoing development of a proposed new ASTM International standard. The new standard, ASTM WK31179 , Practice for Selection and Preparation of Dimension Stone Test Specimens, is being developed by Subcommittee C18.08 on Selection of…
-
The proper selection of assessors can have a direct effect on the outcome of any sensory or consumer test. A proposed new ASTM International standard will help users determine appropriate assessors, give general guidelines for ways to select and recruit respondents, and list the benefits and drawbacks in selecting certain assessors. The proposed new standard, ASTM WK30847 , Guide for Selection of…
-
Product selection is an important, though sometimes neglected, part of the consumer testing process. A proposed new ASTM standard will offer guidelines to bring clarity to this process. The proposed standard, ASTM WK30844 , Guide for Sampling of Product for Evaluation, is being developed by Subcommittee E18.04 on Fundamentals of Sensory, part of ASTM International Committee E18 on Sensory…, ASTM Committee E18 Next Meeting:, April 12-14, 2011, April Committee Week, Anaheim, Calif., Technical Contact:, Julie Boutaghou, Boutaghou LLC, North Oaks, Minn., Phone: 651-788-5550; j ulieboutaghou@msn.com, ASTM Staff Contact:, Scott Orthey, Phone: 610-832-9730; sorthey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8751
-
A proposed new ASTM International standard will help consumer goods developers and manufacturers in the evaluation of their products to ensure product quality, consumer satisfaction and marketing success. The proposed standard, ASTM WK29225 , Guide for Design and Execution of Sensory-Instrumental Correlation Studies, is being developed by a task group of Subcommittee E18.03 on Sensory Theory and…
-
Trona, or sodium sesquicarbonate, is a fine mineral powder that has proven to be effective at removing acid gases from air emissions. While trona can be a useful component of air pollution control systems, it can be difficult to handle, particularly when moisture is present. A proposed new ASTM standard will present a repeatable, precise and accurate test method for analyzing moisture levels in…, ASTM Committee E01 Next Meeting:, Nov. 14-17, November Committee Week, San Antonio, Texas, Technical Contact: J, ames D. Phillip, Solvay Chemicals Inc, Green River, Wyo., Phone: 307-872-6519; jim.phillip@solvay.com, ASTM Staff Contact:, Thomas O'Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8608
-
Petrography is routinely performed on dimension stone for many construction projects in which new stone is being used, and it is often required in technical specifications. In order to facilitate this process, ASTM International Committee C18 on Dimension Stone has developed a new standard, ASTM C1721 , Guide for Petrographic Examination of Dimension Stone. The new standard is under the…, ASTM Committee C18 Next Meeting:, April 21-22, April Committee Week, St. Louis, Mo., Technical Contact:, Michael Scheffler, Wiss, Janney, Elstner Associates Inc., Northbrook, Ill., Phone: 847-272-7400; mscheffler@wje.com, ASTM Staff Contact:, Jeff Adkins, Phone: 610-832-9738; jadkins@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8432/Dec2009
-
Test Method Covers Inductively Coupled Plasma Atomic Emission Spectrometry, A new ASTM International standard will help users properly prepare and analyze various nickel-based alloy samples by inductively coupled plasma emission spectrometry. The standard, ASTM E2594 , Test Method for Analysis of Nickel Alloys by Inductively Coupled Plasma Atomic Emission Spectrometry (Performance-Based Method), will assist users in preparing sample and calibration solutions and with…