A new ASTM International standard supports the growing use of concrete paving slabs for commercial and residential projects. The new specification ( C1782/C1782M , Specification for Utility Segmental Concrete Paving Slabs) determines the minimum flexural strength, dimensional tolerances, and freeze-thaw durability requirements for paving slabs with dimensions ranging from 12 by 12 in. to 48 by 48…, ASTM Committee C15 on Manufacturing Masonry Units Next Meeting:, Dec. 6-8, 2016, December Committee Week, Orlando, Fla., Media Inquiries:, Dan Bergels, tel +1.610.832.9602; dbergels@astm.org, Technical Contact:, David Smith, Interlocking Concrete Pavement Institute, Chantilly, Va., tel +1.703.657.6900; dsmith@icpi.org, ASTM Staff Contact:, Krista Robbins, tel +1.610.832.9689; krobbins@astm.org Release #10145
-
ASTM International has fully redesigned its International Laboratory Directory, the only directory in the world dedicated to helping manufacturers find the right labs to test their products. Independent laboratories throughout the world rely on thousands of standards and test methods, including many developed by ASTM International. By working with these labs, manufacturers can help ensure that…, Contact:, Anna Spektor, tel +1.610.832.9756; aspektor@astm.org, Media Inquiries:, Dan Bergels, tel +1.610.832.9602; dbergels@astm.org Release #10110
-
ASTM International’s Committee on Manufactured Masonry Units (C15) has presented its top annual award – the Award of Merit – to Steve Talafous of Buildings Consulting Group, Inc. in Minneapolis, Minn., U.S.A. The prestigious award, which includes the accompanying title of fellow, is ASTM’s highest recognition for individual contributions to developing standards. The committee honored Talafous for…, Media Inquiries:, Dan Bergels, tel +1.610.832.9602; dbergels@astm.org Release #10068
-
A proposed ASTM standard could help improve workplace safety by describing proximity alarm systems that can be used to prevent cranes, utility trucks, and other equipment from encroaching inside OSHA minimum approach distances and contacting high-voltage power lines. The standard would be most useful to the construction industry, but it could also help in firefighting, drilling, mining,…, ASTM Committee F18 on Electrical Protective Equipment for Workers Next Meeting:, Oct. 4-7, 2015, Las Vegas, Nev., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Lance Burney, Sigalarm, Sanford, Fla., tel +1.407.321.0722; lance@sigalarminc.com , ASTM Staff Contact:, Kevin Shanahan, tel +1.610.832.9737; kshanahan@astm.org Release #9903
-
In order to keep sound that travels beyond the walls of a particular area, such as medical examination rooms and human resources offices from being overheard by unintended listeners, an ASTM subcommittee specializing in speech privacy is at work on a proposed new standard, WK47433, Performance Specification of Electronic Sound Masking When Used in Building Spaces. “Electronic sound masking…, ASTM Committee E33 Next Meeting:, April 27-28, 2015, April committee week, Anaheim, Calif., Technical Contact:, Kenneth P. Roy, Armstrong World Industries, Lancaster, Pa., tel +1.717.396.5700; kproy@armstrong.com, ASTM Staff Contact:, Kelly Paul, tel +1.610.832.9745; kpaul@astm.org, ASTM PR Contact:, Barbara Schindler, tel +1.610.832.9603; bschindl@astm.org Release #9752
-
Since 2009, the National Fire Protection Association has required arc rated gloves in its NFPA70E, Standard for Electrical Safety in the Workplace. A new ASTM standard will now provide arc rating thermal protective values for gloves, which will allow more gloves to be used inside an arc flash zone when there is no shock hazard. The new standard, ASTM F2675/F2675M , Test Method for Determining Arc…, ASTM Committee F18 Next Meeting:, Oct. 20-23, 2013, Charleston, S.C., Technical Contact:, Hugh Hoagland, ArcWear, Louisville, Ky., Phone: 502-832-9737; hugh@arcwear.com , ASTM Staff Contact:, Kevin Shanahan, Phone: 610-832-9737, kshanahan@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9469
-
A proposed new ASTM International standard will be helpful to the construction industry in designing acoustic properties for buildings. ASTM WK37294 , Test Method for the Laboratory Measurement of Mechanical Impedance of Building Elements and Prediction of the Sound Transmission Loss Performance, is currently being developed by Subcommittee E33.03 on Sound Transmission , part of ASTM…, ASTM Committee E33 Next Meeting:, April 15-16, 2013, April Committee Week, Indianapolis, Ind., Technical Contact:, Peter Jackson, Ward Process, Holliston, Mass., Phone: 774-233-7011; p.jackson@aapusa.com, ASTM Staff Contact:, Steve Mawn, Phone: 610-832-9726; smawn@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9316
-
A proposed new standard being developed by ASTM International Committee F18 on Electrical Protective Equipment for Workers will provide guidance to assist in the required testing of live-line tools. ASTM WK33590 , Guide for In-Service Inspection, Maintenance and Electrical Testing of Insulating Tools (Fiberglass-Reinforced Plastic (FPR) and Wooden Live-Line Tools), is under the jurisdiction of…
-
The
-
Arc protective blankets are used in many electrical applications to protect workers who are stationed near energized electrical parts. While these blankets have been used for years, there have been no testing criteria for their evaluation. A new ASTM International standard will be used to determine the effectiveness of arc protective blankets in suppressing the combined effect of an arc flash and…