Search
Advanced search
Filter by category
Filter by committee
Search results
-
ASTM International’s Fire Committee ( E05 ) is developing a standard that will test fire resistance of wooden utility poles. Utility companies and coating and treatment manufacturers will use the standard to test new products that could protect the poles. “Utility poles are frequently exposed to high intensity wildfires throughout the world,” says ASTM member Brent M. Pickett, Ph.D. “If these…, ASTM Committee E05 on Fire Next Meeting:, June 27-30, 2016, June Committee Week, Chicago, Ill., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Brent M. Pickett, Ph.D., Western Fire Center Inc., Kelso, Wash., tel +1.360.423.1400; brent@westernfire.com , ASTM Staff Contact:, Thomas O’Toole, tel +1.610.832.9739; totoole@astm.org Release #9989
-
ASTM International published a new standard that provides an important test for photovoltaic equipment used to generate solar energy. The standard ( E3006 , Practice for Ultraviolet Conditioning of Photovoltaic Modules or Mini-Modules Using a Fluorescent Ultraviolet (UV) Lamp Apparatus) is used to screen out materials that degrade quickly when exposed to ultraviolet radiation from sunlight.…, ASTM Committee E44 on Solar, Geothermal and Other Alternative Energy Sources Next Meeting:, Nov. 17-18, 2015, November Committee Week, Tampa, Fla., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Sean Fowler, Q-Lab Corp., Lorain, Ohio, tel +1.440.835.8700; sfowler@q-lab.com, ASTM Staff Contact:, Kristy Straiton, tel +1.610.832.9640; kstraiton@astm.org Release #9909
-
Keeping birds away from potentially fatal encounters with building exteriors is the purpose of a proposed new ASTM International standard, ASTM WK47853 , Test Method for Bird Collision Deterrence Material Threat Factor. It is possible that as many as a billion birds are killed every year after colliding with glass on buildings, including many single-family homes — and this is in the United States…, ASTM Committee C14 Next Meeting:, April 14, 2015, Moorestown, N.J., Technical Contact:, Stefan Knust, Ennead Architects, New York, New York, tel +1.212.807.7171; sknust@ennead.com, ASTM Staff Contact:, Thomas O’Toole, tel +1.610.832.9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, tel +1.610.832.9603; bschindl@astm.org Release #9767
-
Escalating costs and increased environmental awareness have made conservation a high priority for anyone concerned with satisfying energy needs for a building. One approach to help control costs is the use of energy control window films, which are the subject of a proposed new ASTM International standard, ASTM WK46378 , Specification for Energy Control Window Films for Residential and Commercial…, ASTM Committee E44 Next Meeting:, Nov. 11-12, November Committee Week, New Orleans, La., Technical Contact:, David Burns, 3M CRAL-Weathering Research Center, St. Paul, Minn., tel +1.651.733.1214; dmburns@mmm.com, ASTM Staff Contact:, Christine DeJong, tel +1.610.832.9736; cdejong@astm.org, ASTM PR Contact:, Barbara Schindler, tel +1.610.832.9603; bschindl@astm.org Release #9693
-
Adopted in 2005, Chapter 7A of the California Building Code describes provisions for attic vents for new construction in wildfire-prone areas. While the California code notes that attic vents should resist the intrusion of embers and flames, there had not been a standard to evaluate such intrusion. A new standard, ASTM E2886/E2886M , Test Method for Evaluating the Ability of Exterior Vents to…, ASTM Committee E05 Next Meeting:, Dec. 8-11, 2014, December Committee, New Orleans, La., Technical Contact:, Stephen Quarles, Insurance Institute for Business and Home Safety, Richburg, S.C., Phone: 803-789-4209; squarles@ibhs.org , ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9617
-
A proposed new ASTM International standard is being developed for mounting plastic pipe and tube in the Steiner tunnel furnace. The draft procedure will help determine the fire-related properties of the pipe and tube in accordance with ASTM E84, Test Method for Surface Burning Characteristics of Building Materials. ASTM WK44535 , Practice for Mounting of Plastic Pipe, Plastic Tubing, Plastic Pipe…, ASTM Committee E05 Next Meeting:, June 23-26, 2014, June Committee, Toronto, Ontario, Canada, Technical Contact:, Joe Zicherman, Fire Cause Analysis, Berkeley, Calif., Phone: 510-649-1300; zicherman46@gmail.com, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9635
-
The use of infrared technology is gaining popularity in the forensic engineering and building science fields. One such use is identifying specific locations of water damage to buildings without requiring complete removal or deconstruction of building systems or facades. A proposed new ASTM International standard will provide guidelines for this usage. ASTM WK44618 , Guide for the Use of Infrared…, Technical Contact:, Robin Girard, Bracken Engineering, Tampa, Fla., Phone: 813-243-4251; rgirard@brackenengineering.com , ASTM Staff Contact:, Kelly Paul, Phone: 610-832-9745; kpaul@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9595
-
A proposed new ASTM International standard will be used to provide guidance for potential stakeholders involved in the financing, construction and maintenance of solar photovoltaic electric power plants. ASTM WK43549 , Practice for Installation, Commissioning, Operations and Maintenance Process, is being developed by Subcommittee E44.09 on Photovoltaic Electric Power Conversion , part of ASTM…, ASTM Committee E44 Next Meeting:, June 25-26, 2014, Indianapolis, Ind., Technical Contact:, Michael D. Whitson, PCGSolar Inc., Phone: 704-497-0367; mike@pcgsolar.com , ASTM Staff Contact:, Christine DeJong, Phone: 610-832-9736; cdejong@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9585
-
A wildland-urban interface is a transitional zone between unoccupied land and human development. There are currently more than 40 million homes located within WUI areas throughout the United States. A proposed new ASTM standard will be used to alleviate the issue of fire conditions that exist due to eaves and other projections in structures that exist in WUI areas. ASTM WK37414, Test Method for…, ASTM Committee E05 Next Meeting:, June 23-26, 2014, June Committee Week, Toronto, Ontario, Canada, Technical Contact:, John Simontacchi, Firefree Coatings Inc., San Rafael, Calif., Phone: 415-459-6488; jsimontacchi@firefree.com , ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9529
-
Incidents involving electrical systems can result in injuries and fatalities that need to be safely and efficiently investigated and a proposed new ASTM guide will provide a basis for such investigations. ASTM WK41392 , Guide for Investigating Electrical Incidents, is being developed by Subcommittee E58.04 on Electrical Incidents , part of ASTM International Committee E58 on Forensic Engineering…, ASTM Committee E58 Next Meeting:, January 2014, in conjunction with National Academy of Forensic Engineers January meeting, Charlotte, S.C. (date to be determined), Technical Contact:, Johannes Laun, Professional Analysis and Consulting Inc., Sugar Grove, Ill., Phone: 630-466-4040; jclaun@proaacl.com, ASTM Staff Contact:, Kelly Paul, Phone: 610-832-9745; kpaul@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9433