Search
Advanced search
Filter by category
Filter by committee
Search results
-
A proposed new ASTM International standard will provide a laboratory conditions test for determining the sustained air performance and exhaust emissions of central vacuum cleaners. ASTM WK14392 , Test Method for Evaluating the Sustained Air Performance and Exhaust Emissions of Central Vacuum Cleaning Units, is being developed by Subcommittee F11.22 on Air Performance , part of ASTM International…, ASTM Committee F11 Next Meeting:, May 5-7, 2014, May Committee Week, Toronto, Ontario, Canada, Technical Contact, : Darrell Nieschwitz, H-P Products Inc., Louisville, Ohio, Phone: 330-875-5556, ext. 2272; dnieschwitz@h-pproducts.com, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9532
-
Rotational viscometry is an easily used tool for determining the viscosity of fluids, including paints, petroleum products and polymer solutions. While standards often make use of rotational viscometry, a procedure for calibrating or validating the measurement is not always part of the standard, which could lead to results that differ from one laboratory to another. A proposed user viscosity…, ASTM Committee E37 Next Meeting:, March 14, 2014, ASTM International Headquarters, West Conshohocken, Pa., Technical Contact:, Roger Blaine, Corvallis, Ore., Phone: 302-559-6827; roger.l.blaine@gmail.com, ASTM Staff Contact:, Tom O'Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9493
-
, ASTM to Partner with ASC to Foster EPD Development, ASTM International will be collaborating with industry to develop Environmental Product Declarations (EPDs) across the 90+ industry markets they support, including sealants. The Adhesive and Sealant Council (ASC) will be partnering with ASTM International to raise awareness of this effort, educate industry on the value of Type III EPDs, and proactively engage industry in developing Product…, ASTM Staff Contact:, Tim Brooke, Phone: 610-832-9729; tbrooke@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9370
-
ASTM International Committee F11 on Vacuum Cleaners has formed a new task group to develop proposed standards for high efficiency particulate air filtration, typically known as HEPA. The task group, part of Subcommittee F11.23 on Filtration, will develop standards to clarify methodology and criteria used to define HEPA filtration for sealed vacuum cleaner systems and filter components used in…, ASTM Committee F11 Next Meeting:, May 20-22, 2013, May Committee Week, Indianapolis, Ind., Technical Contact:, Zoe Wilson, Bissell Homecare Inc., Grand Rapids, Mich., Phone: 616-735-5142; zoe.wilson@bissell.com , ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9338
-
The increase in the number of floor care products in the marketplace that employ wet extraction cleaning systems is the leading factor in the development of a standard that describes a laboratory test for the cleaning effectiveness of such systems. ASTM F2828 , Test Method for Assessing Carpet Cleaning Effectiveness in Terms of Visual Appearance Change When Cleaned with a Wet Extraction Cleaning…, ASTM Committee F11 Next Meeting:, Nov. 12-14, November Committee Week, Atlanta, Ga., Technical Contact:, Kenneth M. Lee, Bissell Homecare Inc., Grand Rapids, Mich., Phone: 616-791-0608; ken.lee@bissell.com, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9290
-
All interested parties are invited to join a new ASTM task group that will be developing standards to measure the performance of battery operated vacuum cleaners. The task group is under the jurisdiction of ASTM International Committee F11 on Vacuum Cleaners . Task Group F11.50.13 on the Development of ASTM Standard Test Methods for the Measurement of Battery-Powered Vacuum Cleaner Performance is…
-
Sealant manufacturers will use a new ASTM International standard to evaluate new products and changes to these products due to exposure to weather. The new standard, ASTM C1735 , Test Method for Measuring the Time Dependent Modulus of Sealants Using Stress Relaxation, is under the jurisdiction of Subcommittee C24.20 on General Test Methods , part of ASTM International Committee C24 on Building…, ASTM Committee C24 Next Meeting:, Jan. 8-10, 2012, Ft. Lauderdale, Fla., Technical Contact:, Christopher C. White, Ph.D., National Institute of Standards and Technology, Gaithersburg, Md., Phone: 301-975-6016; christopher.white@nist.gov, ASTM Staff Contact:, Stephen Mawn, Phone: 610-832-9726; smawn@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9005
-
Rheologists are encouraged to join in the development of a proposed new practice that will help standardize calibration of rotational rheometers to obtain accurate normal force measurements. ASTM WK33687 , Practice for Normal Force Calibration for Rotational Rheometers, is being developed by Subcommittee E37.08 on Rheology , part of ASTM International Committee E37 on Thermal Measurements . The…, ASTM Committee E37 Next Meeting:, Aug. 10-11, in conjunction with the North American Thermal Analysis Society Annual Conference, Des Moines, Iowa, Technical Contact:, Kenneth Aniunioh, Shimadzu Scientific Instruments, Laurel, Md., Phone: 864-633-7690; kenebaano@yahoo.com, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8923
-
Hard surface cleaning products that employ steam comprise a new and growing segment of the vacuum cleaner market, although there are currently no agreed-upon industry-wide standards for such products. A new ASTM subcommittee, F11.40 on Steam Products , part of ASTM International Committee F11 on Vacuum Cleaners , will be developing test methods to measure the performance and durability of steam…
-
The ASTM International Proficiency Testing Center is pleased to offer a 2010 Proficiency Testing Program on Thermal Analyses of Plastics (TAP) to laboratories who need a statistical quality assurance tool that will enable them to improve and maintain a high level of performance in conducting ASTM Differential Scanning Calorimetry (DSC), Oxidative-Induction Time (OIT) by Differential Scanning…, ASTM D3418, , Standard Test Method for Transition Temperatures and Enthalpies of Fusion and Crystallization of Polymers by Differential Scanning Calorimetry (DSC);, ASTM D3850, , Standard Test Method for Rapid Thermal Degradation of Solid Electrical Insulating Materials By Thermogravimetric Method (TGA); and, ASTM D3895, , Standard Test Method for Oxidative-Induction Time of Polyolefins by Differential Scanning Calorimetry. For each test trial, laboratory participants receive two sample materials along with interactive electronic data report forms and test instructions. Using the specified ASTM program tests, participating laboratories conduct the tests of their choice that they routinely run. Upon completion of…