A proposed new ASTM International standard is being developed for mounting plastic pipe and tube in the Steiner tunnel furnace. The draft procedure will help determine the fire-related properties of the pipe and tube in accordance with ASTM E84, Test Method for Surface Burning Characteristics of Building Materials. ASTM WK44535 , Practice for Mounting of Plastic Pipe, Plastic Tubing, Plastic Pipe…, ASTM Committee E05 Next Meeting:, June 23-26, 2014, June Committee, Toronto, Ontario, Canada, Technical Contact:, Joe Zicherman, Fire Cause Analysis, Berkeley, Calif., Phone: 510-649-1300; zicherman46@gmail.com, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9635
-
A wildland-urban interface is a transitional zone between unoccupied land and human development. There are currently more than 40 million homes located within WUI areas throughout the United States. A proposed new ASTM standard will be used to alleviate the issue of fire conditions that exist due to eaves and other projections in structures that exist in WUI areas. ASTM WK37414, Test Method for…, ASTM Committee E05 Next Meeting:, June 23-26, 2014, June Committee Week, Toronto, Ontario, Canada, Technical Contact:, John Simontacchi, Firefree Coatings Inc., San Rafael, Calif., Phone: 415-459-6488; jsimontacchi@firefree.com , ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9529
-
A new test method is the latest in a series of ASTM International standards being developed to address the protection of exterior portions of structures during fires. The new standard, ASTM E2726/E2726M , Test Method for Evaluating the Fire-Test-Response of Deck Structures to Burning Brands, is being developed by Subcommittee E05.14 on External Fire Exposures , part of ASTM International…
-
A new ASTM standard will provide the United States building codes with a test method designed to test a heating, ventilation and air conditioning duct system or its materials for fire resistance and other durability requirements. ASTM E2816 , Test Methods for Fire Resistive Metallic HVAC Duct Systems, was developed by Subcommittee E05.11 on Fire Resistance , under the jurisdiction of ASTM…
-
Halon 1211 is employed in hand-held fire extinguishers on civilian aircraft. A new ASTM International standard will be used to test Halon 1211 to ensure that the product will provide the required level of fire protection and is free of harmful impurities that could affect its safety in use. ASTM D7673 , Specification for Halon 1211, Bromochlorodifluoromethane (CF2BrCl), was developed by…, ASTM Committee D26 Next Meeting:, June 15, 2011, June Committee Week, Anaheim, Calif., Technical Contact:, Mark L. Robin, DuPont Fluoroproducts, Wilmington, Del., Phone: 302-999-5002; mark.l.robin@usa.dupont.com, ASTM Staff Contact:, Christine DeJong, Phone: 610-832-9736; cdejong@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8791
-
Discussions concerning how easily test results for dimension stone test specimens can be influenced by improper or nonuniform preparation methods have led to the ongoing development of a proposed new ASTM International standard. The new standard, ASTM WK31179 , Practice for Selection and Preparation of Dimension Stone Test Specimens, is being developed by Subcommittee C18.08 on Selection of…
-
Fire test laboratories, caulk and sealant manufacturers, and code officials will be the primary users of a new ASTM International standard, ASTM E2690 , Practice for Specimen Preparation and Mounting of Caulks and Sealants to Assess Surface Burning Characteristics. The standard was developed by Subcommittee E05.22 on Surface Burning, which is part of ASTM International Committee E05 on Fire…, ASTM Committee E05 Next Meeting:, June 12-15, 2011, June Committee Week, Anaheim, Calif., Technical Contact:, Paul Hough, Armstrong World Industries, Lancaster, Pa., Phone: 717-396-4195; pahough@armstrong.com, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8723
-
Subcommittee E05.11 on Fire Resistance is responsible for two new standards recently approved by ASTM International Committee E05 on Fire Standards. FIRE-RESISTANCE EXPERIMENTS It is a common practice to modify the tests contained in ASTM E119 , Test Methods for Fire Tests of Building Construction and Materials, in order to gather information on the effect of altering specific variables. However…
-
Petrography is routinely performed on dimension stone for many construction projects in which new stone is being used, and it is often required in technical specifications. In order to facilitate this process, ASTM International Committee C18 on Dimension Stone has developed a new standard, ASTM C1721 , Guide for Petrographic Examination of Dimension Stone. The new standard is under the…, ASTM Committee C18 Next Meeting:, April 21-22, April Committee Week, St. Louis, Mo., Technical Contact:, Michael Scheffler, Wiss, Janney, Elstner Associates Inc., Northbrook, Ill., Phone: 847-272-7400; mscheffler@wje.com, ASTM Staff Contact:, Jeff Adkins, Phone: 610-832-9738; jadkins@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8432/Dec2009
-
Among the proposed new standards that ASTM Committee E05 on Fire Standards is currently working on are two that cover aspects of fire exposure. Committee E05 is meeting in Atlanta in December and welcomes participation in its standards developing activities., Roof Field Vent Response, Embers from wildfires can travel through the air up to four miles away from the fire source, particularly in areas where wind is often prevalent during fire season. These embers can then enter structures through ventilation systems and other openings in a building envelope, resulting in fires being ignited from within a structure. A proposed new ASTM standard will cover a test for the resistance…, Fire Response, Subcommittee E05.14 is also working on ASTM WK25760 , Guide for Quantification of Fire Exposures. The proposed standard will cover fire exposure metrics that will be used in the development of fire test methods. According to Jon Traw, president, Traw Associates Consulting, and chairman of Task Group E05.14.08, the proposed standard will serve as a critical tool in the development of appropriate…, ASTM Committee E05 Next Meeting:, Dec. 6-9, ASTM Committee Week, Atlanta, Ga., Technical Contacts:, (WK23700) Gregory Daniels, O’Hagin’s Inc., Rohnert Park, Calif., Phone: 707-303-3660; gdaniels@ohaginvent.com ; (WK25760) Jon Traw, Traw Associates Consulting, Whittier, Calif., Phone: 562-789-7583; trawassoc@yahoo.com, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8423/Dec2009