Search
Advanced search
Filter by category
Filter by committee
Search results
-
Activated carbon is processed to have small, low-volume pores that increase the surface area available for adsorption. It has applications in the medical, environmental and energy realms, among others. Since 1962, ASTM International Committee D28 on Activated Carbon has developed standards that play a pre-eminent role in how activated carbon is used. A D28 subcommittee, D28.02 on Liquid Phase…, WK47401, Xylenol Orange Dye, The xylenol orange dye test is a way to determine the relative adsorption rate of unused or reactivated carbons by adsorption of xylenol orange from aqueous solution. This is an important means for deciding which type of activated carbon to use to a specific water treatment application. “Activated carbon performance can roughly be defined as a combination of the ability to adsorb a particular…, WK47421, Particle Size Distribution, Mercury flue gas, home water filters and potable water treatment are the main applications in which powdered and fine mesh carbons are used. A proposed new test method will describe how a laser light scattering technique can determine the particle size distribution of fine mesh activated carbon. ASTM member Neal Megonnell, vice president, sales and marketing, Haycarb USA, says the proposed test…, ASTM Committee D28 Next Meeting:, April 27, April Committee Week, Anaheim, Calif., Technical Contact:, (WK47401) Adam Redding, Ph.D., Evoqua Water Technologies LLC, Northwest, Pa., tel +1.724.719.0805; adam.redding@evoqua.com and (WK47421) Neal E. Megonnell, Haycarb USA, Pittsburgh, Pa., tel +1.412.709.7487; neal@haycarbusa.com, ASTM Staff Contact:, Kelly Paul, tel +1.610.832.9745; kpaul@astm.org, ASTM PR Contact:, Barbara Schindler, tel +1.610.832.9603; bschindl@astm.org Release #9731
-
Knowing that the floor beneath you is safe is something most of us take for granted. A proposed new ASTM International standard will help people who have to think about, and test for, floor safety all the time. The proposed new standard is ASTM WK47030 , Practice for Evaluating Concrete Floor Systems to Receive Resilient Flooring. The World Floor Covering Association and the Floor Covering…, ASTM Committee F06 Next Meeting:, Nov. 12-13, November Committee Week, New Orleans, La., Technical Contact:, George Donnelly, George Donnelly Testing and Inspections, Hot Springs, Ark., tel +1.501.915.0626; info@moisturetesting.com, ASTM Staff Contact:, Stephen Mawn, tel +1.610.832.9726; smawn@astm.org, ASTM PR Contact:, Barbara Schindler, tel +1.610.832.9603; bschindl@astm.org Release #9706
-
For more than 100 years, cork tile has been commonly used as a floor and wall covering for residential and commercial use. A new ASTM International standard, ASTM F3008 , Specification for Cork Floor Tile, specifies requirements for cork floor coverings made from agglomerated composition cork supplied in tile form, which is designed to be used with a factory finish or an in situ finish, or both.…, ASTM Committee F06 Next Meeting:, May 7-8, 2014, Clearwater, Fla., Technical Contact:, Christopher Capobianco, Spartan Surfaces, Patchogue, N.Y., Phone: 631-275-6494; christopher@spartansurfaces.com, ASTM Staff Contact:, Stephen Mawn, Phone: 610-832-9726; smawn@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9523
-
A recently published ASTM International standard covers a new type of resilient flooring tile product based on a polyester binder. ASTM F2982 , Specification for Polyester Composition Floor Tile, was developed by Subcommittee F06.80 on Specifications , part of ASTM International Committee F06 on Resilient Floor Coverings . “ ASTM F2982 sets forth an explicit set of compositional and performance…, ASTM Committee F06 Next Meeting:, May 22-23, 2013, May Committee Week, Indianapolis, Ind., Technical Contact:, Thomas Erisman, Armstrong World Industries, Lancaster, Pa., Phone: 717-396-5354; tcerisman@armstrong.com, ASTM Staff Contact:, Stephen Mawn, Phone: 610-832-9726; smawn@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9271
-
Since the late 1970s, precast box sections have become an important component in the construction of culverts, storm drains and sewers, but there has not been a comprehensive standard for the installation of such sections. A new ASTM International standard fills this gap. ASTM C1675, Practice for Installation of Precast Reinforced Concrete Monolithic Box Sections for Culverts, Storm Drains and…, Technical Contact:, Roman Selig, Hamilton Kent LLC, Birmingham, Ala., Phone: 205-910-0690; roman.selig@hamiltonkent.com, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9243
-
Load and resistance factor design methodology developed by the American Association of State Highway and Transportation Officials plays a key role in a proposed ASTM standard on the design of culverts and storm drains. ASTM WK38166 , Specification for Manufacture of Precast Reinforced Concrete Three-Sided Structures for Culverts and Storm Drains Designed According to AASHTO LRFD, is being…, Technical Contact:, Balaram K. Singh, P.E., Michigan Department of Transportation, Lansing, Mich., Phone: 517-335-2174; singhb@michigan.gov, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact, : Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9311
-
Non-destructive moisture meters are now widely used in determining moisture levels in concrete, gypsum concrete and other types of floor slabs. A new ASTM International standard qualifies the types of meter suitable for this purpose and provides guidelines for how, where and when such moisture meters are used and what limitations exist. The new standard, ASTM F2659 , Guide for Preliminary…, ASTM Committee F06 Next Meeting:, Nov. 10-11, New Orleans, La., Technical Contact:, Sean Fallon, Dublin, Ireland, Phone: +011-353-1-285-1861; seanfallon@ireland.com, ASTM Staff Contact:, Stephen Mawn, Phone: 610-832-9726; smawn@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #870/Oct2010
-
Special considerations need to be made for flooring in multi-purpose rooms, particularly those in child care buildings, elementary schools and long-term care facilities. ASTM International Committee F06 on Resilient Floor Coverings is currently developing a proposed new standard for such flooring. WK24836 , Specification for Active Area, Multipurpose Flooring, is under the jurisdiction of…
-
ASTM International Committee C13 on Concrete Pipe has approved a new standard that covers flexible joints for concrete box sections using rubber gaskets for leak resistant joints. Subcommittee C13.08 on Joints for Precast Concrete Structures developed ASTM C1677 , Specification for Joints for Concrete Box, Using Rubber Gaskets. “This specification will provide a uniform minimum level of…
-
Mercury emissions from flue gases in coal-fired power plants are a large source of atmospheric mercury in the United States, but no standard for determination of mercury adsorption currently exists. One promising method of controlling these emissions involves the injection of powdered activated carbon into the flue gas. A proposed new ASTM International standard would evaluate the performance of…